Home Companies Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

JLSLF-10HP Industrial Air Cooled Air Chiller For Data Center Server Room Cooling

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Add: No.19,Second Street,Huangling Road,Lubian Village,Chashan Town,Dongguan,Guangdong,China.

Contact name:Jlschiller

Inquir Now

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

JLSLF-10HP Industrial Air Cooled Air Chiller For Data Center Server Room Cooling

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

JLSLF-10HP Air Cooled Air Chiller Data Center, Server Room And Network Equipment Cooling


Product Description:


Industrial air coolers (Industrial Air Cooler) are usually used to cool and reduce the ambient temperature, by circulating air through a cooling medium (such as cooling water or refrigerant) to blow cold air to reduce the indoor temperature. Their energy efficiency mainly depends on the energy consumption of the fan and the refrigeration or cooling capacity of the cooling medium. Energy-efficient industrial air coolers typically feature efficient fan designs and economizer cooling systems to reduce energy consumption.



 

Working Principle:


The working principle of the industrial air cooler is to achieve the cooling effect through the airflow generated by the fan. The following is the basic working principle of industrial air coolers:

1. Fan: An industrial air cooler consists of one or more high-efficiency fans. Fans create airflow by rotating blades or propellers.

 

2. Inhale air: The fan sucks in the surrounding air and introduces it into the inside of the cooler.

 

3. Radiator: The air cooler usually contains one or more radiators. Radiators are heat exchangers made of thermally conductive materials that can efficiently absorb and conduct heat.

 

4. Cooling medium: The air cooler uses a cooling medium (such as water or refrigerant) to absorb heat. The cooling medium flows through the radiator and exchanges heat with the surrounding air.

 

5. Heat transfer: Heat is transferred from the object or equipment to be cooled to the cooling medium. This can be achieved by means of direct contact, convection or radiation.

 

6. Cooling effect: The cooling medium absorbs heat when in contact with the object to be cooled, and then takes away the heat through the airflow generated by the fan. In this way, the temperature of the object to be cooled can be reduced to achieve a cooling effect.

 

The specific working principle and design of industrial air coolers may vary with different models and applications. Certain industrial air coolers can also be combined with other systems, such as refrigeration or air conditioning systems, to provide more efficient cooling and temperature control.

 

 

 

 

 

Techinical Parameters:

 

ModelJLSLF-3HPJLSLF-5HPJLSLF-8HPJLSLF-10HPJLSLF-12HPJLSLF-15HPJLSLF-20HPJLSLF-25HPJLSLF-30HPJLSLF-40HP
Cooling capacityKW/h8.8514.7523.629.535.444.255973.7588.5118
Kcal/h24,33840,56364,90081,12597,350121,688162,250202,813243,375324,500
Temperature range3℃~35℃
Power supply1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ
Total powerKW2.574.317.659.911.413.718.822.5927.136.1
CompressorType Hermetic scroll type or piston
PowerKW2.253.7567.5911.251518.7522.530
RefrigerantType R22/R407c/R134a/R410a
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
 volumeKg1.834.867.2912151824
Cooling windm³/h37080015602300275033604100480054006200
Cold wind pressurePa340520780890100010001000100010001000
Fan powerKW0.350.50.751.51.82.233.754.56
Cooling air volumem³/h30005000800010000120001500020000250003000040000
Blower powerKW0.280.360.60.750.91.21.21.62.43.6
Outlet pipe diametermm100125150150150150200200250300
Machine sizeLmm800110013301330133015501760197020002100
Wmm60070075075075078086090011301400
Hmm1190124013301330133014601560170016601750
Unit weightKg150260360420460530600700820950

 

 

 

 


Application Industry:


Air coolers (also known as cooling fans or air cooling systems) are widely used in many industries and fields, the following are some common application industries:

1. Information technology industry: Air coolers are commonly used in data centers, server rooms and network equipment to dissipate heat and maintain the normal operating temperature of the equipment.

 

2. Industrial production: In the process of industrial production, air coolers are used to cool heat sources in machines, equipment and processes to ensure the stable operation of the equipment.

 

3. Construction industry: Air coolers are used in the air conditioning systems of large buildings, commercial centers and office buildings to provide cooling and ventilation.

 

4. Manufacturing industry: Air coolers are used in the manufacturing industry to cool heat sources in mechanical equipment, machine tools and processes to ensure production efficiency and quality.

 

5. Medical industry: In hospitals, laboratories and medical facilities, air coolers are used to cool medical equipment, scanners and experimental equipment to ensure their normal operation and stability.

 

6. Agriculture and greenhouse planting: In the agricultural field, air coolers are used to cool the greenhouse and maintain the stability of the crop growth environment.

 

7. Automobile industry: Air coolers are used in the field of automobile manufacturing and maintenance to cool engines, engines and other parts of vehicles.

 

8. Aerospace: In the field of aerospace, air coolers are used to cool equipment such as aircraft, spacecraft and engines to ensure their normal operation and safety.

 

These are just some common application areas of air coolers. In fact, air coolers are also widely used in many other industries and fields to meet different cooling and heat dissipation needs.

 


  Automotive Manufacturing          Chemical Engineering              Electronics Industry                 Electroplating Industry
 

  Injection Molding Industry          Pharmaceutical Industry         Plastic Packaging Industry            Printing Industry

 

 

Upport and Services:


Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

Packing and Shipping:


Chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

Is the energy efficiency of industrial air coolers and industrial chillers affected by the ambient temperature?


Yes, the energy efficiency of industrial air coolers and industrial chillers is usually affected by the ambient temperature.

For industrial air coolers, an increase in ambient temperature increases the cooling load as they need to cool the hot air to a lower temperature. When the ambient temperature is high, industrial air coolers require more energy to achieve the same cooling effect, resulting in a reduction in energy efficiency.

 

For industrial chillers, the increase in ambient temperature will also have an impact on their energy efficiency. Industrial chillers provide cooling capacity through a cooling medium such as cold water or refrigerant. When the ambient temperature rises, the cooling effect of the cooling medium may be affected, requiring more energy to achieve the required cooling effect, resulting in a decrease in energy efficiency.

 

In addition, changes in ambient temperature may also affect the operational stability and efficiency of industrial air coolers and industrial chillers. For example, a high temperature environment can lead to increased operating pressure on equipment, increased energy consumption and reduced system efficiency. Therefore, when selecting and using industrial air coolers and industrial chillers, it is necessary to consider the influence of ambient temperature, and conduct reasonable energy efficiency evaluation and selection according to specific conditions.

 

Hot Products

JLSF-100HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
JLSF-75HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
Product Description: Mold Cooling Water Chiller is a cooling equipment specially used in the mold ...
JLSF-25HP Air Cooled Water Chiller Space-Saving And Durable For Research Facilities Product ...
Product Description: Aluminum-plastic blister packaging machine and heat-sealing machine circulation ...
JLSW-150D Reliable Water Cooled Screw Chiller For Pharmaceuticals, Hospitals, Laboratories Product ...