Professional Tengine Trace Dissolved Oxygen Analyzer / Meter - MDO10AC For Power Plant
1. Application
Used for trace dissolved oxygen ( ppb ) measurement
• Power plant
• Semiconductor industry
• Pharmaceutical industry
• Food industry
2. Features and Benefits
• Based on the innovative principle of utilizing fluorescence to measure dissolved oxygen,no need to replace membranes and only low-maintenance needed.
• No oxygen consuming during operating , do not need stir or flow.
• Digital sensor has good anti-interference performance and high stability, and the cable length is available in hundreds of meters.
• “plug and play” sensor, and dual-channel transmitter • operates either 1 or 2 sensors.
• Modbus RS485/RS232 or Profibus DP network connection for data transmission is Optional
• 3 Relays with programmable hysteresis provide high-limit alarm, low-limit alarm or timer.
• A built-in data logger with the capacity to store data for up to 10 years
3. Specifications
Performance characteristics | |
Measuring Range | 0~1800μg/L(ppb),Temperature: 0~50℃ |
The lowest value detected | 1ppb |
Accuracy | ±1ppb±3% |
Response time | 90%<40s, at 20ºC |
Temperature compensation | Automatic |
Calibration | Factory calibrated, also can be calibrated by customer on site |
Display | LCD displays data including date, time, measurement value, trendline, etc., English menu |
Data storage | Auto-save function(Automatic Data Storage for up to 10 years), power-off data protection |
Setup | Completed by transmitter pushing the buttons on the transmitter |
Outputs | |
Analog Outputs | Two isolated 0/4-20 mA output( maximum load 800 ohms), optional selection of 3.8mA or 21mA(under the condition of malfunction) |
Relay outputs | 3 Relays with programmable hysteresis, alarm or timer function optional |
Relay capacity | 2A, 250VAC |
Digital Communication | MODBUS RS232/RS485,Profibus DP is optional |
Power supply | |
AC power supply | 85~265 VAC, 50Hz/60Hz |
DC power supply | 24 VDC ±10% |
Physical parameters | |
Dimension of Transmitter | 231×185×119mm(W×H×D) |
Dimension of Sensor | Φ45×118 |
Materials | --Transmitter: PC --Sensor: 316L stainless steel |
Process connection of sensor | 1 inch cone male thread |
Environmental conditions | |
Ingress protection | --IP66 (transmitter) --IP68 (Sensor) |
Operating Temperature | --Transmitter: -20~60℃ --Sensor: 0~50℃ |
Ambient Relative Humidity | 0 to 95%, non-condensing |
Operating Pressure | ≤7.5Bar |
4. Ordering Information
Ordering Information | ||||||
Transmitter Selection | ||||||
| Channel number | Signal output | Power version | |||
MDO |
|
|
| |||
| code | meaning | code | meaning | code | meaning |
| 1 | Single channel | 0 | 4~20mA | AC | 220VAC |
| 2 | Dual channel | 1 | RS 485(Modbus) | DC | 24VDC |
|
|
| 2 | RS 232(Modbus) |
|
|
|
|
| 3 | Profibus DP |
|
|
Example: MDO10AC, single channel dissolved oxygen transmitter, output 4~20mA, 220V AC Power Supply. | ||||||
Sensor Selection | ||||||
| Install mode | Cable length | ||||
MDO-S |
|
| ||||
| code | meaning | code | Meaning | ||
| 0 | Immersion installation | C10 | 10m cable | ||
|
|
| CXX | XXm cable | ||
Example: MDO-S0C10, a MDO sensor, Immersion Mounting , 10m cable. |
(3) Accessories
FA0000: Immersion mounting bracket, stainless steel
FA0031: Circulation mounting accessory, PVC
FA0800: Instrument protective housing, stainless steel
FA0810: Instrument protective housing, stainless steel, with heater unit