VICTOR 385 Digital Earth Resistance Tester Surface Resistance Meter ASTM Standard
 
VICTOR 385   Surface Resistance Meter electronic components Electrostatic Instrument Static Detector Insulation Resistance Tester
 
I. DISCRIPTION
It is a surface or surface grounding resistance tester. According to ASTM standard D-257 parallel electrode sensing way to do the surface resistance test. It can simply and repeatedly test various types of the surface, such as conduction type, release type and insulating surface.
 
II. OPERATION

  • Open the battery door and install the battery inside. Keep the device from the surface of the tested object, hold the red “TEST” button, and at this time the insulation light on.
  • Put the device on the surface of the tested object and press “TEST” button, the light LED will indicate the order of magnitude of impedance of the surface.

103=1KΩ GREEN LED

104=10KΩ GREEN LED

105=100KΩ GREEN LED

106=1MΩ GREEN LED

107=10MΩ GREEN LED

108=100MΩ GREEN LED

109=1000MΩ GREEN LED

1010=10000MΩ GREEN LED

1011=100000MΩ GREEN LED

1012=1000000MΩ RED LED

>1012=INSULATION RED LED
3, Earthing resistance test

Insert the earth wire into the ground socket, so that it is insulated from the right side of the meter (with the same side of the socket) and the alligator clamp is connected to the earth wire. Place the meter on the surface of the object, and hold the "TEST" button, and continue lighting LED indicating the magnitude of the earthing resistance. The unit of measurement is Ω.

 

III. CALIBRATION
This meter need a calibration every 12 months, use a decade resistance box, put the standard resistance bridged between the two parallel electrodes of the meter to see if the indication is within the target range. Or you can send the meter back to our factory and do the calibration.
The transition point of impedance value is 0.5 logarithm (i.e. 3.16*10n). The linear value of the transition point is (+10%) of the median value of each measuring range.
 

VICTOR 385 Grounded Resistance Tester
Operation Way: Auto Range

Measuring Level10 Level
Switch Point0.5 Level
Switch Point Accuracy±0.5 Level
Accuracy±10%
Repetition±5%
Test Voltage9V
Operation Temperature5℃~49℃(41°F~120°F)
Storage Temperature-15℃~+60℃
Relative Humidity0%~90%
Product Size130mm*70mm*25mm
Battery9V DC
Product Weight170g

 

 














Hot Products

VICTOR 923E Digital Multmeter with colorful display Smart Auto range multimeter Measurement Range ...
VICTOR 925 Digital Multmeter with full screen display Smart Auto range multimeter lithrum battery ...
VC97 Auto Range Digital Multimeter 3999 Counts large LCD Display With True RMS 1. INTRODUCTION The ...
VC890C+ Digital Multimeter 2000 Counsts Manual Range True RMS Capacitance Resistance Transistor ...
VICTOR 88C Manual Range Digital Multimeter 1999 Counts large LCD Display With True RMS 1000V/20A AC ...
VC830L Manual Range VICTOR Digital Multimeter 1999 Counts Large Lcd Display VC830L Manual Range ...