Home Companies Shenzhen Veikong Electric Co., Ltd.

9.4A 4KW MPPT Solar Pump Inverter IP20 380V GPRS Auto Track

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

9.4A 4KW MPPT Solar Pump Inverter IP20 380V GPRS Auto Track

Country/Region china
City & Province shenzhen
Categories Power Supplies
InquireNow

Product Details

IP20 380V 4KW Solar Pump Inverter Work With Solar Panel And Water Pump

 

Product Feature:

 

1. Advanced MPPT Technology: Maximum MPPT Efficiency: 99%;


2. Auto-track All Daytime;


3. Auto dormancy/wake-up, Under-voltage restart;


4. Support both AC and DC power input (optional);


5. Water Level Monitoring: dry run protection, overflow protection Record: generated power, pumped water, running time;


6. The whole water pumping systems running not rely on grid power or battery;


7. Protection Functions: support low frequency, dormancy, dry-run, over-current, minimum power and other protection functions;


8. Default Auto-running: auto-running by keypad, auto-running by IoT, auto-running by Terminals;


9. Excellent Control Performance: make sure the system auto-running with unattended, maximum output frequency is 600hz under VF control;


10. Intelligent IoT: support GPRS module, for remote control.

 

Solar Pump Inverter Special Parameters

 

Function codeNameDescriptionDefaultProperty
47 Group solar pumping special group
P00.03RESET

0:NO ACTION

11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

12:Restore default to factory parameter 13:Clear tripping record

0
P00.06Source of the Operation Command

0:keypad

1:terminal

2:communication

Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

0
P00.07Numeric frequency setting00.00Hz~maximum frequency50.00Hz
P00.11Application Macro

01:Output three phase 50HZ

02:Output three phase 60hz

21:Output single phase with capacitor 50hz

22:Output single phase with capacitor 60hz

31:Output single phase without capacitor 50hz

32:Output single phase without capacitor 60hz

00
P01.06Maximum frequency10.00~600.00Hz50.00Hz
P01.08Upper limit frequencyLower limit frequency-maximum frequency50.00Hz
P07.03Relay 1 Output terminal function group(T1A T1B T1C)

0:No function

1:READY

2:RUN

3:Error1(stop fault)

4:Error2(same as Error1 except undervoltage)

5:Warning output(fault but in running)

3
P11.01AC asynchronous motor TYPE

0:Three phase AC asynchronous motor

1:Single phase AC asynchronous motor without starting capacitor

0
P11.02Motor rated power

0.1kW~710.0kW

Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

Depend
P11.03Motor rated voltage10V~2000VDepend
P11.04Motor rated current

P11.02<30kW:0.01A

P11.02>=30kW:0.1A

Depend
P11.05Motor rated frequency1.00Hz~600.00Hz50.00Hz
P11.06Motor rated RPM1~60000rpmDepend
P21.00Monitoring display

0:Standard mode (display frequency only)

1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

0
P23.15Output phase loss function0.0-30%, 0% means output phase detections shielded30%
r27.15Accumulative running timeUnit:hour 
P47.00Solar pump Mppt function enable

0: invalid

The parameters behind the 47 group cannot be changed!

1: Enable, to enable the special mppt function of the PV pump inverter

 

 

 

1
P47.01

Solar pump control mode

 

Units digit’s: Startup mode

0: Manual start, the start mode is determined by P00.06;

1: automatic start,

When P00.06 change, the association changes here.

P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start

P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start

Ten digit’s: MPPT function

0: MPPT is disabled; CVT control is used (voltage is given as P47.04).

1: Enable MPPT.

11
P47.03Automatic start timingIn auto start mode, set the time from power on to start. It is also waiting time to start600
P47.04MPPT starting voltage

Set the starting voltage of the MPPT algorithm.

When the MPPT function is disabled, this value is the reference voltage.

305V(530V)
P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
P47.06Light detection timeSee P47.05 for explanation.60s
P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s
P47.08MPPT tracking step lengthThe amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point.2V
P47.09Regulator proportional gain0.001~1.00 It is for immediate response speed, it is not recommended to change0.05
P47.10Regulator integral gain0.001~0.100 tracking response.it is not recommended to change0.05
P47.28Starting coefficient0.000~1.0000.850
P47.30Fast speed function

Unit digit:fast starting

0:Disable 1:Enable

Ten digit:Fast mppt tracking

0:Disable 1:Enable

11
 

 


 

Product Application

 

 

 

FAQ

 

1. Does the product need to set a lot of parameters?

 

No, it doesn't. The inverter has a self-adaptive and self-learning function. It is automatic start and stop, you can press Run key to start, or you just wait for P47.03=600S(Default) then it will automatically start

 

2. Could it replace my previous PV pumping inverter?

 

Yes, of course. Selecting inverter model according to the rated voltage, current and power of the water pump. A bit more is better. Then take off the old one and put ours on, the system will work.

 

3. How to design solar PV water pump system?

 

Key point: the rated VOC and VMP and power of the PV Array need to match the input range of the inverter. If needed, we will provide technical support online.

 

4. How to make the water pump system work without sunshine?

 

Usually, solar PV water pump system can meet the needs of pumping water.

If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design

Hot Products

560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...
400KW 450KW 500KW AC Drive VFD Work For Big Motor Automation Machines Performance features Advanced ...
IP20 VFD 280KW 315KW 355KW Frequency Inverter With LCD Keyboard Multifunctional and user friendly ...
VFD variable frequency inverter For Heavy Load 55kw 75kw 90kw 110kw VEIKONG hot selling VFD VFD500M ...
22KW 30KW 37KW 45KW VFD AC Drive Manufacturer Vector Control Shenzhen Veikong Electric CO.,Ltd. a ...
55KW 75KW 90KW Frequency VFD AC Drive Manufacturer Vector Control Why choose VEIONG: 1, 180% torque ...