IP20 380V 15KW Solar Pump Inverter Hybrid Inverter Support With LCD Keyboard

 

 

1. How to achieve Automatic start after stop?
 
If it is controlled by keyboard no need to set any parameter(P47.03 is waiting time)If you want to control by
external switch,First set P00.06=1 and use a wire or switch to connect com and DI1,When the switch is
closed, the drive run, when the switch is open, the drive stop
 
2. How to use a float in the water tank to stop the pump if the tank is full?
 
If your float signal is digital signal Use float switch to short DI 3 and com , see diagram 1.3
 
3.Use level probe in the well for protection against dry running
 
(1)solution: See self learning of dry run
(2)solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
(3)solution: If your sensor is digital switch ,just short D4 and com
(4)solution:If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and P41.03-P41.06
 
4.How to set minimum frequency ( for example) 30hz and maximum 50HZ
 
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
 
5.If pump is 60HZ frequency, how to set max frequency?
 
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

 

Solar Pump Inverter Special Parameters

 

Function codeNameDescriptionDefaultProperty
47 Group solar pumping special group
P00.03RESET

0:NO ACTION

11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

12:Restore default to factory parameter 13:Clear tripping record

0
P00.06Source of the Operation Command

0:keypad

1:terminal

2:communication

Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

0
P00.07Numeric frequency setting00.00Hz~maximum frequency50.00Hz
P00.11Application Macro

01:Output three phase 50HZ

02:Output three phase 60hz

21:Output single phase with capacitor 50hz

22:Output single phase with capacitor 60hz

31:Output single phase without capacitor 50hz

32:Output single phase without capacitor 60hz

00
P01.06Maximum frequency10.00~600.00Hz50.00Hz
P01.08Upper limit frequencyLower limit frequency-maximum frequency50.00Hz
P07.03Relay 1 Output terminal function group(T1A T1B T1C)

0:No function

1:READY

2:RUN

3:Error1(stop fault)

4:Error2(same as Error1 except undervoltage)

5:Warning output(fault but in running)

3
P11.01AC asynchronous motor TYPE

0:Three phase AC asynchronous motor

1:Single phase AC asynchronous motor without starting capacitor

0
P11.02Motor rated power

0.1kW~710.0kW

Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

Depend
P11.03Motor rated voltage10V~2000VDepend
P11.04Motor rated current

P11.02<30kW:0.01A

P11.02>=30kW:0.1A

Depend
P11.05Motor rated frequency1.00Hz~600.00Hz50.00Hz
P11.06Motor rated RPM1~60000rpmDepend
P21.00Monitoring display

0:Standard mode (display frequency only)

1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

0
P23.15Output phase loss function0.0-30%, 0% means output phase detections shielded30%
r27.15Accumulative running timeUnit:hour 
P47.00Solar pump Mppt function enable

0: invalid

The parameters behind the 47 group cannot be changed!

1: Enable, to enable the special mppt function of the PV pump inverter

 

 

 

1
P47.01

Solar pump control mode

 

Units digit’s: Startup mode

0: Manual start, the start mode is determined by P00.06;

1: automatic start,

When P00.06 change, the association changes here.

P00.06=0, when inverter starts and stops by keypad control, it is automatically modified to 1-automatic start

P00.06=1, when inverter starts and stops by terminal control.it is automatically changed to 0-manual start

Ten digit’s: MPPT function

0: MPPT is disabled; CVT control is used (voltage is given as P47.04).

1: Enable MPPT.

11
P47.03Automatic start timingIn auto start mode, set the time from power on to start. It is also waiting time to start600
P47.04MPPT starting voltage

Set the starting voltage of the MPPT algorithm.

When the MPPT function is disabled, this value is the reference voltage.

305V(530V)
P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
P47.06Light detection timeSee P47.05 for explanation.60s
P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s
P47.08MPPT tracking step lengthThe amount of change in the bus voltage during an MPPT cycle. The larger the value, the faster the maximum power point is found, but the lower the accuracy of the maximum power point.2V
P47.09Regulator proportional gain0.001~1.00 It is for immediate response speed, it is not recommended to change0.05
P47.10Regulator integral gain0.001~0.100 tracking response.it is not recommended to change0.05
P47.28Starting coefficient0.000~1.0000.850
P47.30Fast speed function

Unit digit:fast starting

0:Disable 1:Enable

Ten digit:Fast mppt tracking

0:Disable 1:Enable

11
 

 


 

Product Application

 

 

 

FAQ

 

1. Does the product need to set a lot of parameters?

 

No, it doesn't. The inverter has a self-adaptive and self-learning function. It is automatic start and stop, you can press Run key to start, or you just wait for P47.03=600S(Default) then it will automatically start

 

2. Could it replace my previous PV pumping inverter?

 

Yes, of course. Selecting inverter model according to the rated voltage, current and power of the water pump. A bit more is better. Then take off the old one and put ours on, the system will work.

 

3. How to design solar PV water pump system?

 

Key point: the rated VOC and VMP and power of the PV Array need to match the input range of the inverter. If needed, we will provide technical support online.

 

4. How to make the water pump system work without sunshine?

 

Usually, solar PV water pump system can meet the needs of pumping water.

If there is no sunshine, the system will not work. But out inverter could also support AC input. So, connect the power grid or diesel power generation to the inverter, the pumping system will work. If necessary, keep switch and interface locations during the system design

Hot Products

VFD variable frequency inverter For Heavy Load 55kw 75kw 90kw 110kw VEIKONG hot selling VFD VFD500M ...
22KW 30KW 37KW 45KW VFD AC Drive Manufacturer Vector Control Shenzhen Veikong Electric CO.,Ltd. a ...
55KW 75KW 90KW Frequency VFD AC Drive Manufacturer Vector Control Why choose VEIONG: 1, 180% torque ...
185KW 200KW 220KW Frequency VFD AC Drive Manufacturer Vector Control High speed accuracy and wide ...
Vector Control VFD AC Drive 1.5KW 2.2KW 4KW Frequency 440V 480V Product feature: 1. Complete ...
40HP 50HP 60HP VFD Frequency Drive For AC Motor Textile Machinery Features High-performance vector ...