Home Companies Shenzhen Veikong Electric Co., Ltd.

VEIKONG VFD500 Variable Frequency Inverters Converters for Process PID Control and Simple PLC

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

VEIKONG VFD500 Variable Frequency Inverters Converters for Process PID Control and Simple PLC

Country/Region china
City & Province shenzhen
Categories Chargers
InquireNow

Product Details

Veikong Brand 45kw VFD500 Variable Frequency Inverters Converters Ac Drive

 

Key Feature

 

01, Starting torque: 180%, 0.25Hz (sensor-less vector control 2), 150%, 0.5Hz (sensor-less vector control 1);


02, Speed adjustable range: 0-50Hz: 1:200 (sensor-less vector control 2), 1:100 (V/Hz control, sensor-less vector control 1);


03, Speed accuracy: +/-0.2% (sensor-less vector control 1&2), +/-0.5% (V/Hz control);


04, Speed fluctuation: +/-0.3% (sensor-less vector control 1&2);


05, Torque response: less than 10ms (sensor-less vector control 1&2);


06, Over load capability: 150% 1minute, 180% 10 seconds, 200% 0.5 second, once every 10 minutes;


07, Output frequency: 0.00-600.00Hz, or customized like 1MHz;


08, Abundant frequency setting sources;


09, DC brake start frequency: any frequency in the range of 0Hz to 600.00Hz;


10, Diverse input and output terminals;


11, Ambient temperature: -20°C~60°C;


12, High precise torque limit, process PID control, simple PLC, wobble frequency control, mechanical brake control, field weakening control, all-side protection, etc.


13, Online and offline auto-tuning both available;


14, Extreme short-time acceleration can be operated without trip, such as 0.1s from 0Hz to 50Hz.

 

Technical Specification

 

Item

Specifiation

Input

Inuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range

-15%~10%

Input frequency

50Hz / 60Hz,fluctuation less than 5%

Output

Output Voltage

3phase:0~input voltage

Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

Control

Control mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating mode

Speed control,Torque control(SVC and VC)

Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

frequency range

0.00~2000.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

Carrier frequency

1kHz~12kHz(Varies depending on the type)

Startup method

Direct start (can be superimposed DC brake); speed tracking start

Stop method

Deceleration stop (can be superimposed DC braking); free to stop

Maincontrol function

Jog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN

Function

Keypad

LED Digital keyboard and LCD keypad(option)

Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG card

Incremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card

Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

Protection

Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function

Environment

Installation location

Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude

0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m

Ambient temperature

-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C

Humidity

Less than 95%RH, without condensing

Vibration

Less than 5.9 m/s2 (0.6 g)

Storage temperature

-20°C ~ +60°C

Others

Installation

Wall-mounted, floor-controlled cabinet, transmural

Protection level

IP20

cooling method

Forced air cooling

EMC

CE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

Product Application

 

 

Hot Products

5.5KW 7.5KW 11KW 15KW 18.5KW VFD AC Drive Manufacturer Vector Control 5.5KW 7.5KW 11KW 15KW 18.5KW ...
AC 380v 220v IP20 OVP VFD Variable Frequency Drive Manufacturers 30kw 40hp variable frequency drive ...
VFD Variable Frequency Inverter For Heavy Load 30kw 37kw 45kw 55kw VFD ac drive frequency inverter ...
380V Input VFD Variable Frequency Drive 0.75kw To 710kw Three Phase AC drive vfd variable speed ...
7HP 10HP 15HP 25HP 30HP Frequency Inverter AC Drive With Vector Control Product Advantages 1, With ...
560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...