 Vault Room Door Stainless Steel Material Door For Basement Strong Room Vault Room Door With Escape Door With Day Gate

 

Technical description: Our vault door complies with the American UL 608 BULLETIN-2007 "UL Safety Standard: Anti-theft vault door and template" standard requirements. The products are suitable for the financial industry, jewelry companies, insurance companies, private vaults, etc.

 

Basic functions: Fireproof, anti-drilling, anti-cutting, anti-impact, etc., and the protection level meets the requirements of UL standards.

 

Advantages:

1. Waterproof, corrosion resistance

2. Sturdy construction, wear resistance, high load bearing

3. Easy to install, supply each product an installation instruction

4.QC inspect in production, avoid any mistake 100% re-inspect before packing, double ensure all product are perfect

5.Size and color can be customized according to your requirement.

6.Professional export package to ensure safe transportation

 

Comliance sheet
SpecificationsCustomers RequirmentsOur Product
Door DescriptionUL 608 class 2 vault doorMeet the requirments; UL 608 class 2 vault door
Match;2000mmH*1000mmW(Customized)Meet the requirments; 2000mmH*1000mmW
Over door frame size/2255mmH*1498mmW
Wall opening size/2300mmH*1650mmW
Overall door thickness/470mm
Door thicknessCash and other Vault Rooms (except main vaults): Vault door shall be
not less than 3.5” thick, overall. Two Main Vaults at Ground Floor: Vault door shall be not less than 4.5”,
overall.
Meet the requirments; 320mm
Wall thickness/320mm(minimum)
Safe classUL 608 class 2Meet the requirments; UL 608 class 2, certificate number: BP21099
Protection level(anti-burglary time)60 minutesMeet the requirments; 60 minutes
Protection layer thickness/150mm
HingeRight or left hingeMeet the requirments; Right or left hinge
Relocking devices7 independent glass relockers shall activate against any forced
attempt to dislodge main locking system
Meet the requirments; 7 independent glass relockers shall activate against any forced
attempt to dislodge main locking system
Bolt Work7 heavy cylindrical through bolts, 2 bolts on top and 2 bolts on
bottom, securing all 4 sides of door. Each bolt shall have diameter of not
less than 38 mm.
Meet the requirments; 7 heavy cylindrical through bolts, 2 bolts on top and 2 bolts on
bottom, securing all 4 sides of door. Each bolt shall have diameter of not
less than 38 mm.
FinishPatinted finishMeet the requirments; Patinted finish
Grill gatePatinted finish steel grill gate with two
high security 5-lever mortise dead locks to provide security when the
vault door is open.
Meet the requirments; Patinted finish steel grill gate with two
high security 5-lever mortise dead locks to provide security when the
vault door is open.
Lock (changeable)The Digital lock set should be meeting with VdS Class 3 or
equivalent for secured vault door operation acceptable to SAMA.
Meet the requirments; UL listed; UL certificate number:BP21004
Lock must have redundant operation and Redundant Bass
Cables with AES 256 encryption.
Meet the requirments;
The Data must be stored inside the locks, inside the Vault Door
not in the Input unit.
Meet the requirments;
The Input unit must be dial type with spy proofing.Meet the requirments;
The lock shall work as standalone as well as network based
remotely monitored and Audit with dedicated software.
Meet the requirments;
Lock shall be operated with 220/240V uninterruptible power
supply and re-chargeable battery pack in case of power failure.
Meet the requirments; Surelock battery management and AC power optional
The Input unit with keypad and LCD display shall be installed
outside of the vault door replacing the mechanical locking unit.
Meet the requirments;
The lock shall be installed inside the vault Door on the secure
side of the vault door.
Meet the requirments;
Each lock inside the vault door and its input unit shall be
connected with special concealed security power and data
cables with redundancy. Provision shall be made for future
connection to Client’s central network for remote monitoring of
vault operations.
Meet the requirments;
The main vault door and the Emergency vault door shall have
separate electronics locks.
Meet the requirments;
Emergency doorSame lock and safe class with main doorMeet the requirments; UL 608 class 2, two (2) high quality digital
locking systems; Clear size:W450mm*H500mm,
Outline size:W533mm*H544mm; Emergency door weight:140KG
Other accessoriesmicroswitch for alarm& light control c/w wiring in the frame;Emergancy ventilator;Meet the requirments;
Quality assuranceManufacturer Qualifications: Company specializing in manufacturing vault doors
for at least 10 years.
Meet the requirments; 19 years experiences in manufacturing vault doors.
TRANSPORTATION, HANDLING AND STORAGEDeliver, store and handle vault doors in a manner to prevent damage and
deterioration.
Meet the requirments;
Provide packaging such as cardboard or other containers, separators, banding,
spreaders and paper wrappings to protect all items.
Meet the requirments;
Store doors and frames upright, in a protected dry covered area, at least 100
mm or more above ground or floor and at least 6 mm between individual pieces.
Meet the requirments;
Submit a written at least 5 year warranty, starting from substantial handover of
the project, for all items specified under this Section, signed by manufacturer and
the contractor, against all the defects, including bowing, twisting and malfunction
of locking system.
Meet the requirments;

 

 

 

Hot Products

High Security UL 608 Standard Steel Vault Safe Room Strong Room Private Vault Technical Description ...
High Security UL 608 Standard Steel Vault Safe Room Strong Room Private Vault Technical Description ...
Traditional Basement Vault Room High Grade Level Security Room Modular Vault Room. 1. Standards: it ...
Strong Room Vault Safe Room Doors For Security UL Class 3 Protection Level 230mm Thickness Room ...
High Grade Level Basement Vault Security Room Bank Combination Vault And Ventilation System. 1:It is ...
Strong Anti Burglary UL Class 2 150mm Thickness Vault Safe Room In Bank 1,Jinzheng technology having ...