Home Companies Shenzhen Consnant Technology Co., Ltd.

Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

Shenzhen Consnant Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China

Contact name:Kevin Huang

Inquir Now

Shenzhen Consnant Technology Co., Ltd.

Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

Country/Region china
City & Province shenzhen guangdong
Categories Inverters & Converters
InquireNow

Product Details

Mutiple Mode Hybrid PV Energy Storage Grid Solar Inverter

 

Product Instruction:

 

     HT series is a new hybrid PV energy storage inverter controller integrating PV energy storage,mains charging

and storage and AC sine wave output. Using DSP control through advanced control algorithms, it comes with high

response speed, high reliability, high industrialization standard and other characteristics.

     Four charging modes are available: only PV, mains priority, PV priority, and hybrid charging by mains & PV;

     two output modes: inverter and mains are available to meet different application needs.

 

Key Feature:

1. Full digital voltage; current double closed loop control, combined with advanced SPWM technology to output

pure sine wave.
2. Two output modes and 4 charging modes are available for choice.
3. AdvancedMPPT technology with efficiency up to 99.9%.
4. LCD screen design, with 3 LED indicators, for dynamic display of system data and run status; ON/OFF rocker

switch controls AC output.
5. Power saving mode reduces no-load loss.
6. Intelligent variable speed fan ensures efficient heat dissipation, and thereby extends system life.
7. Double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery

access.
8. Multiple protections provide 360 ° all-round protection for the system. Complete protections include multi-electrical

appliance air switch short circuit protection, overvoltage and undervoltage protection, overload protection, back-flow

protection, etc.
9. Horizontal installation facilitates cabinet combination installation.
10. Lithium battery can be activated by both mains and PV panel.

 

Specification Reference:

ModelHT4830S80-145HT4840S80-145HT4850S80-145HT4825U80-145HT4830U80-145HT4835U80-145
Mains mode
Rated input voltage220/230Vac110/120Vac
Input voltage range(170Vac~280Vac) ±2%
(90Vac-280Vac)±2%
(90Vac~140Vac) ±2%
Frequency range47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Conversion time10ms (typical)
(bypass and inverter)
Maximum bypass overload current40A
Inverter mode
Output voltage waveformPure sine wave
Rated output power (VA)3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output power (W)3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output voltage (Vac)230Vac(200/208/220/240Vac Settable)120Vac(100/105/110Vac Settable)
Output voltage error±5%
Output frequency range (Hz)50Hz ± 0.3Hz
60Hz ± 0.3Hz
Efficiency>92%>91%
Overload protection(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds;
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds;
Peak power6000VA8000VA10000VA4000VA4500VA5000VA
Loaded motor capacity2HP3HP4HP1HP2HP2HP
Bypass circuit breaker specification63A
Rated battery input voltage48V (minimum starting voltage 44V)
Battery voltage range40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set)
Eco modeLoad ””≤ 50W
AC charging
Maximum charge current0-60A0-40A
Charge
current error
± 5Adc
Charge voltage range40 - 58Vdc40 - 60Vdc
Circuit breaker specification(AC IN) 63A/(BAT) 125A
PC charge
Maximum PV open circuit voltage145Vdc
PV operating voltage range60-145Vdc
MPPT voltage range60-115Vdc
Battery voltage range40-60Vdc
Maximum output power4200W
PV charge current range (settable)0-80A
Charge short circuit protectionBAT circuit breaker and fuse
Wiring protectionReverse polarity protection
Hybrid charging Max charger current specifications (AC charger+PV charger)
Max charger current(can be set)0-140A0-120A
Certified specification
Specification certificationCE(EN62109)
EMC certification levelEN61000, C2
Operating temperature range-15°C to 55°C
Storage temperature range-25°C ~ 60°C
RH range5% to 95% (conformal coating protection)
Noise≤”60dB
Heat dissipationForced air cooling, adjustable air speed

 

 

Product Maintenance and Fault Handling:

No.ProtectionsRemarks
1PV current/power limiting protectionWhen charging current or power of the PV array configured exceeds the PV rated, it will charge at the rated.
2PV night reverse-current protectionAt night, the battery is prevented from discharging through the PV module because the battery voltage is greater than the voltage of PV module.
3Mains input over voltage protectionWhen the mains voltage exceeds 280V (230V model) or 140V (120V model), the mains charging will be stopped and switched to the inverter mode.
4Mains input under
voltage protection
When the mains voltage is lower than 170V (230V model /UPS mode) or 90V (120V model or APL mode), the mains charging will be stopped and switched to the inverter mode.
5Battery over voltage protectionWhen the battery voltage reaches the overvoltage disconnection point, the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged.

 

FaultsHandling measures
No display on the screenCheck if the battery air switch or the PV air switch has been closed;
if the switch is in the "ON" state; press any button on the screen to exit the screen sleep mode.
Battery overvoltage protectionMeasure if the battery voltage exceeds rated, and turn off the PV array air switch and Mains air switch.
Battery undervoltage protectionCharge the battery until it returns to the low voltage disconnection recovery voltage.
Fan failureCheck if the fan is not turning or blocked by foreign object.
Heat sink over temperature protectionWhen the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
Bypass overload protection, inverter overload protection① Reduce the use of power equipment;
② Restart the unit to resume load output.
Inverter short circuit protection① Check the load connection carefully and clear the short-circuit fault points;
② Re-power up to resume load output.

Hot Products

Modular Online UPS 30KW with built-in Lithium Battery Pack 384VDC 50AH Modular Online UPS Technical ...
Online Modular Type UPS 30KW RS232 RS485 Dry Contact Built In LifePO4 Battery CNM330-30KW-400KVA ...
Product Description: Application: IDC(Internet Data Center),computing center,ISP(Internet Service ...
Product Description: Features: ■ Superior energy saving: Efficiency>96% at 50%-75% rated load, and...
5KW Integrated outdoor solar power system 2.56KWH Product Description: ■ The whole system integratio...
Integrated outdoor solar power system 3KW/5KW 2.56KWH Characterization: ■ The whole system ...