Product Details

THDi < 3% UPS Uninterrupted Power Supply Modular Online UPS

30 - 1200KVA​

 

 


CNM330 series is a modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size

 


Application:


Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.
 


Features:


■ Superior energy saving :
■ Easy-to-install:
■ Easy-to-maintain:
■ Easy-to-modify:
■ Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on)
■ Provide large LCD touch screen (optional)
■ Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
■ Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
■ Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet
■ Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
■ Intelligent battery management maintains battery automatically to prolong the battery life
■ The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
■ UPS power module supporting hot swappable, capacity upgrade extremely simple.
■ Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system


Working Principal:


Modular UPS use double conversion on-line structure, including rectifier, inverter, battery charger, control circuit, the input and the output battery connector breaker. have function that is input power factor compensation. All modules can be online hot-swappable, providing the highest level of availability, and maintainability.
If one power modular failure will not affect the system normal working, power module can be online hot-swappable all power module paralel is managed by the control board, in accourdance with the unified parameters running, one power module fault can be automatically exit parallel system, will not cause harm to the whole parallel system.

Modular UPS system use independent static bepass module, do not use multiple static bypass structure, avoid caused overload damage modules because of multiple bypass module uneven current when UPS turn to bypass working. The module parallel output volage accuracy is ±1%, parallel circulation current<1%.

Static bypass module contains bypass static switch only, excluded static switch of the amain circuit output; therefore, replacing static bypass modulewill not cause the system power down or transfer manual maintenance bypass, which can realize online hot-swap replacement.
 

 

High Availability Configuration Structure

 

 

Static switch module:

 

■ System standard configuration module

■ Adopts SCR and AC contactor in parallel

■ High reliability, strong overload ability: 1000% for 1 min

■ Transfer time less than 1ms

■ Have strong self-test, inter-lock and full-protection function

 

 

Power Module:

 

■ Freedom choice of capacity configuration according demand, easy to expand

■ Online double-conversion design to ensure the output quality

■ Each module has independent digital intelligent control

■ Each module can work independently

■ Each module has a separate charging system

■ All modules can be hot-swappable, easy for online maintenance

■ Each UPS module provide 4.5KW charge capacity, equivalent to 10 to 12A

 


Rich Management Interface

 

Advanced battery management

■ All floating automatic conversion

■ Temperature compensation

■ Discharge to suspend automatic voltage regulation

■ Battery self-diagnosis and self-inspection

■ Battery capacity prediction

■ Discharge time estimates

■ Low voltage forecasting warning

 

 

Data recorder

 

Every 10 ms records a core electrical data, and in Fault occurs, the freezing failure 1 to 1.5 before work. The core of the cycle frequency electrical data Accurately record the cause of failure, to help the accident diagnosis and accurate positioning Rapid diagnosis to improve maintainability, the data will be recorded before a failure or overload occur.

 

 

Advanced self-diagnosis

 

■ Inverter and rectifier circuit working condition monitoring

■ Battery capacity and status detection

■ Equipment working environment temperature testing

■ Ease of maintenance and management of equipment

■ Can each fan of fault detection, and replace the fan without power

 

 

System
Frequency50Hz/60Hz (Settable)
Mains Synchronization Range±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection LevelIP20
Communication PortsRS232,RS485,dry contact, SNMP card, EPO, generator port
System efficiency>96% at load above 50%, >95% at load above 25%
Operation Temperature0-40ºC
Storage Temperature-25ºC~70ºC ( without battery)
Humidity0-95% (no-condensing)
Noise(dB)55-62dB,Adjusted with load
Weightmodule:PM2020KVA power module : 35KG
module:PM3030KVA power module : 35KG
module:PM4040KVA power module : 40KG
Dimension (W x D x H)mm3 module cabinet600X900X1135
5 module cabinet(5 battery cabinet option)600X1100X2070/
6 module cabinet600X900X1535
10 module cabinet900X900X2080
power module440X650X132(3U)(10KVA/20KVA/30KVA)
 

 

 

 


Technical Specifications:

 

 

ModelCNM330 20-300KVA
Capacity20-300KVA
Main Input 
Input Voltage380V/400V/415V
Input Frequency Range50/60Hz
Power FactorFull load>0.99 ,Half load >0.98
THDiTHDi<3%
Input Power Soft-start Function5-30s settable
Input Voltage Ranges228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range40-70HZ
Battery
Battery Voltage±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy±1%
Bypass
Bypass Input Voltage380/400/415VAC 3-phase 4-wire
Voltage RangeDefault value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload CapacityLong term at 135% rated load ,150%<load<180% more than 10 min,
load>1000% 100ms
Output
Inverter Output Voltage380/400/415VAC 3-phase 4-wire
Voltage Accuracy±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDVTHDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor0.9
Three Phase Angle Accuracy120°± 0.5°
Current Crest Ratio3:1
Overload Capacity110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time0ms,15ms (Eco Mode)

(Optional South America 208V must be derating use)

Hot Products

3 Phase 4 Wire Modular UPS System Input PF > 0.99 Input THDi < 3% 300KVA CNM330 series is modular ...
Tunnel Power Supply Modular UPS System 3PH / 4W 3 Level MOSFET Inverter Technology CNM330 series is ...
Parallel Redundancy Modular UPS System High Efficiency Three Phase 30 - 90KVA Description: CNM330 ...
Low THDi Modular UPS System With Strong Overload Ability 30 - 1200KVA Description: CNM330 series is ...
THDi < 3% UPS Uninterrupted Power Supply Modular Online UPS 30 - 1200KVA​ CNM330 series is a modular ...