Home Companies Shenzhen Consnant Technology Co., Ltd.

Expandable Commercial Ups Battery Backup , 200KVA Three Phase Online Ups Unit

Shenzhen Consnant Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China

Contact name:Kevin Huang

Inquir Now

Shenzhen Consnant Technology Co., Ltd.

Expandable Commercial Ups Battery Backup , 200KVA Three Phase Online Ups Unit

Country/Region china
City & Province shenzhen guangdong
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

CNG330 Series Low Frequency Online UPS 10-200KVA
 


Model:CNG330 10-200KVA(3Ph/3Ph)
Nominal Input Voltage: 380/400/415VAC
Output Power Factor:0.8
 

 
Model powerCNG330 10-200KVA
10KVA15KVA20KVA30KVA40KVA60KVA80KVA100KVA120KVA160KVA200KVA
Capacity8KW12 KW16 KW24 KW32 KW48 KW64 KW80 KW96KW128 KW160 KW
Input
Rated voltage400 Vac three-phase
Voltage range±20%
Frequency range45-65Hz
Power factor>0.92with harmonic filter
Current harmonic distortion<5%with harmonic filter
Soft Start0-100% in10"
Bypass Input
Rated voltage400Vac single-phase
Permitted voltage range±15%(selectable from ±10% to ±25% from front panel)
Rated frequency50/60Hz
Permitted frequency range±2%(selectable from ±1% to ±5% from front panel)
Standard featuresBack Feed protection; split bypass line
Batteries
TypeMaintenance-free lead-acid VRLA AGM / GEL;NICd
Battery voltage384VDC480VDC
Maximum recharge current(A)0.2×C10
AC ripple voltage<1%
Inverter Output
Number of phases3+N
Rated voltage(V)400Vac
Regulation of the output voltage380~424Vac phase/neutral(from control panel)

Crest factor
(Ipeak / Irms)

3:1
Static stability±1%
Dynamic stability±5%
Frequency50/60Hz configurable
Overload110% 125% 150% of the rated current for 5h/10'/1'
Frequency stability±0.05% on mains failure;±2%(selectable from ±1% to ±5%)with mains supply present
Remote signalingVolt free contacts
Remote controlsEPO and Bypass
CommunicationRS232 + romote contacts
Operation temperature0ºC/ + 40ºC
Relative humidity<95% non condensing
Noise54dBA at 1m50-65dBA at 1m
Protection degreeIP20
Efficiency smart modeup to 98%
ComplianceSafety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
 

 
Application:


Servers,
Local area Network(LAN),
Data centers,
Telecommunications,
Electro-medical equipment


High intelligence and reliable power supply:

 

  • Maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
  • The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
  • On-line double conversion technology (VFI) with isolation transformer on the inverter output.
  • Watch & Save 3000 software as standard and can be remotely monitored using the Power Net Guard system from anywhere in the world.
  • Additional battery extension packs allow the standard battery routine to be extended up to several hours.


Maximum battery care:

  • Battery deep discharge protection;
  • Temperature compensating charger;
  • Built-in automatic and manual battery test feature.


Simple to install:


Capability to install the UPS into any distribution system(neutral not required on rectifier input);
Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (Necessary on UPS without an output transformer).


High reliability:
 

  • Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes)
  • An isolation transformer on the inverter output;
  • Full microprocessor control with no-break static and manual bypasses;
  • IGBT technology.


Other characteristics:

 

  • 0.8 power factor, suitable for powering ICT and Industrial loads;
  • High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD with several languages;


Back feed protection: To avoid energy feeding back into the mains supply cause a fault occur.


Maximum reliability and availability:The UPS continue to work in parallel even if one of the interconnecting communication cables is disconnected (CLOOSED LOOP).


Low consumption level:selectable Economy Mode efficiencies >98% 


Expandabilityparallel up to 8 units and can be expanded any time to suit power requirements without influencing the initial investment.
 
Sales Service: 
 
1. 2% spares together with shipment for urgent issue.
2. All of the necessary documents such as drawing, manaul etc.
3. We will provide the online service by mail
4. Online Guide will be provied all the time. We also can desptach engineer to assist you solve the problem if necessary. But you are requested to pay for the cost of ticket, hotel etc.

 

 

Hot Products

Online Hot Swappable UPS Uninterrupted Power Supply N + X Redundancy 30 - 1200KVA Technical ...
LCD display power module Data Center Modular UPS 30-300KVA ​The CNM331 series three phases input and ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...