Home Companies Shenzhen Consnant Technology Co., Ltd.

Modular Industrial Ups Power Supply 30 - 300KVA , Three Phase Uninterruptible Power Systems

Shenzhen Consnant Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China

Contact name:Kevin Huang

Inquir Now

Shenzhen Consnant Technology Co., Ltd.

Modular Industrial Ups Power Supply 30 - 300KVA , Three Phase Uninterruptible Power Systems

Country/Region china
City & Province shenzhen guangdong
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

UPS Uninterrupted Power Supply Parallel Redundancy Modular Online 30 - 300KVA

 

Technical Specifications

ModelCNM330 20-300KVA
Capacity20-300KVA
Main Input 
Input Voltage380V/400V/415V
Input Frequency Range50/60Hz
Power FactorFull load>0.99 ,Half load >0.98
THDiTHDi<3%
Input Power Soft-start Function5-30s settable
Input Voltage Ranges228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range40-70HZ
Battery
Battery Voltage±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy±1%
Bypass
Bypass Input Voltage380/400/415VAC 3-phase 4-wire
Voltage RangeDefault value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload Capacity

Long term at 135% rated load ,150%<load<180% more than 10 min,

load>1000% 100ms

Output
Inverter Output Voltage380/400/415VAC 3-phase 4-wire
Voltage Accuracy±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDVTHDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor0.9
Three Phase Angle Accuracy120°± 0.5°
Current Crest Ratio3:1
Overload Capacity110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time0ms,15ms (Eco Mode)
System
Frequency50Hz/60Hz (Settable)
Mains Synchronization Range±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection LevelIP20
Communication PortsRS232,RS485,dry contact, SNMP card, EPO, generator port
System efficiency>96% at load above 50%, >95% at load above 25%
Operation Temperature0-40ºC
Storage Temperature-25ºC~70ºC ( without battery)
Humidity0-95% (no-condensing)
Noise(dB)55-62dB,Adjusted with load
Weightmodule:PM2020KVA power module : 35KG
module:PM3030KVA power module : 35KG
module:PM4040KVA power module : 35KG
Dimension (W x D x H)mm3 module cabinet600X900X1135
5 module cabinet(5 battery cabinet option)600X1100X2070/
6 module cabinet600X900X1535
10 module cabinet900X900X2080
power module440X650X132(3U)(10KVA/20KVA/30KVA)


(Optional South America 208V must be derating use)




CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size
 

 

Battery Charging capacity:

 

■ 3.375KW @if the ambient temp is 0 ℃~30℃, No output power duration

■ 3.0KW@if the ambient temp is 30℃-35℃, No output power duration.

■ 2.7 KW@if the ambient temp is 35℃~40℃, No output power duration

Ripple Voltage at battery charging :

Ripple voltage < 1.414%(RMS value)nominal battery voltage at float charging or const voltage boost charging, (notes: battery cable max. long is 10m.)

 

End Cell Voltage:

 

1.67V/cell (can be set by Background setting)

Voltage for charge:

Equalize charge: 2.35/cell Float charge: 2.27/cell (can be set by Background setting)

 

Input power factor:

 

In all the condition of load and voltage input power factor is 1 .This means that the input current demand lower. So the input cable, air switch demand lower, it will reduce the cost .In addition, because UPS appears as pure resistance of the mains grid power, reduce the operation cost. Most of the traditional system power factor is 0.8, leading to higher front-end costs and operating costs .Require additional capacitors in power factor correction, this is extra spending, lead to lower efficiency. Please see the input voltage and current wave.

 

Advantage-self aging:

 

The unit can aging itself in full load condition without any actual load. All the unit will be aging in factory at least 8 hours. Also can be used as AC or DC back feed load to burn-in AC or DC product

The Design Concept of High Efficiency and Energy Saving Environmental Protection

The machine efficiency

Under the condition of the same power module can achieve greater load capacity, can save a lot for the customer at the same time because the cost of efficiency loss, Using the newest switching devices (CoolMos) + intelligent control technology, realize super wide Efficient operation area, under 25% to 100% load rate are in the best running state, especially In a typical 45% to 75% range, efficiency is as high as 96% For customers to save investment.

 

The whole machine efficiency:

 

Improve the system output power and the reliability of the system can achieve greater load capacity, better protect customers load equipment operation safety.

Single static bypass

When use multiple independent small power bypass module will produce machine uneven flow caused by bypass module impedance mismatch, so single static bypass design can avoid this problem and can use maintenance switch realize hot-swap when repair UPS, to improve system stability and reliability.

 


Application:
Application IDC(Internet Data Center)

Computing center

ISP (Internet Service Provider )

Telecom , Finance, bank and securities , Tax

Hospital system , industrial automation

Precision equipment, etc.

 

 



Features:

■ Superior energy saving :
Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%
■ Easy-to-install:
Top or bottom cabling, no need of input cabling cabinet.
■ Easy-to-maintain:
Full front access, UPS, failed part can be replaced shortly
■ Easy-to-modify:
The number of batter y cells can be configured flexibly, so the original batteries can be used when modifying the legacy
system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS.
■ Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on).
■ Provide large LCD touch screen (optional)
■ Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
■ Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
■ Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion
without centralized bypass cabinet
■ Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
■ Intelligent battery management maintains battery automatically to prolong the battery life
■ The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
■ UPS power module supporting hot swappable, capacity upgrade extremely simple.
■ Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system




 

 

 

 

 

Hot Products

Online Hot Swappable UPS Uninterrupted Power Supply N + X Redundancy 30 - 1200KVA Technical ...
LCD display power module Data Center Modular UPS 30-300KVA ​The CNM331 series three phases input and ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X ...