Brief introduction of instrument structure
The portable halogen detector is a reliable leak detector for detecting refrigerant leakage in air conditioning and refrigeration systems, as well as halon gas leakage in fire extinguishers. It is small, portable and highly sensitive, the probe can be bent at will, so the position of the leak can be easily detected
Wide Application
1.Inspection of Automobile air-conditioning
2.Household Air Conditioning Testing
3.Fluorine detection in household refrigerators
4.halon gas fire extinguisher detection
Advanced leak detection technology and manufacturing of excellent devices in Germany
Quality Seiko Build by heart
Product Parameters:
source | DC6V/4 Section 7# Basic Battery |
Maximum sensitivity | 14 g/year |
preheating time | 6 seconds |
reaction time | instant |
Battery life | About 50 hours |
outline dimension | 70*45*43mm |
Refrigerant with halogen can be detected
#Manually adjust sensitivity
#Acousto-optic alarm indication
#Precision testing High reliability
#Handbag Easy to carry
7 major functional advantages
1.All tests included Brine refrigerant
2.Unique sensitivity manual adjustment Section function, convenience Practical
3.Precision circuit design Skillful and unique High sex
4.Acousto-optic alarm indication
5.Adopt quality transmission Sensors, hair Now it's tiny Halogen gas
6.Bendable long Handle probe, detectable Measuring any position Source leakage
7.Portable design With a handbag Easy to carry
Scope of Use
1, Capable of detecting air conditioning, refrigeration systems and refrigerant recovery devices, instruments respond to all halogen gases, including chlorine and fluorine, but not limited to these:
CFCS e.g. R12, R11, R500.R503, etc.
HCFCs e.g. R22, R123, R124, R502, etc.
HCFCs e.g. R134a, R404a, R125, etc.
2, Detection of ethylene oxide gas leak holes in medical equipment,(detection of halogen thrusters)
3, Detection of SF-6 in high voltage switches
4, Detection of most fluorine, chlorine, bromine (halogen gas)
5, Detection of halon gas in the fire extinguishing system
Fault Detection Chart
question | cause | handle |
Turn on and hear howls | Lack of batteries | Replacement of batteries |
desensibilization | Lack of batteries | Check power supply voltage, replace Battery |
desensibilization | Probe loss | Switch the probe |
desensibilization | Dirty probe | Switch probe or clean Probe |
Instrument cannot detect leakage | Insufficient batteries or dirty probes or Probe loss | Replacement of battery replacement probe or cleaning the probe |
Sensitivity switch to the end Still couldn't hear howling | Battery voltage is too low | Replacement of batteries |