MITECH MHBS-3000 Digital Display Brinell Hardness Tester
Overview
MITECH MHBS-3000 Digital Display Brinell Hardness Tester, based on
the mechanical principle of hard alloy indenter pressing into the
sample surface to produce indentation, realizing the material
hardness measurement by measuring the diameter of the
indentation.It is novel and high reliable with accurately
measurement. With LED display, simple operation, it can visually
display the test results to meet the hardness testing requirement
for the quality control and qualified assessment of the workpiece
sample. It is widely used in metal processing and manufacturing,
various metal material’s failure analysis and other fields like
colleges and research institutions It’s to improve the work
efficiency, product qualification rate, saving production costs
necessary professional precision testing equipment.
Technical Parameters
Technical specifications | Technical Parameters |
The power series | 612.5N(62.5kgf),980N(100kgf),1225N(125kgf),1837.5N(187.5kgf),
2450N(250kgf),4900N(500kgf),7350N(750kgf),9800N(1000kgf), 14700N(1500kgf),29400N(3000kgf) |
Measuring range | 8 – 650 HBW |
Testing Force Application Mode | Automatic (loading, holding, unloading) |
Indenter objective lens conversion mode | manual operation |
display usage | LCD liquid crystal display |
Microocular magnification | 20X |
Test force holding time | 0~60s |
Minimum division | 0.005mm |
Max sample height | 225mm |
Max sample width | 270mm |
Max distance from head to body | 135mm |
Voltage | AC 220V/50Hz |
Size | 786*565*245mm |
Total Weight | 130kg |
Indication accuracy
Standard Block | Indicating Error%(H) | Repeatability Error |
≤125 | ±3 | 0.035`d |
125˂HBW≤225 | ±2.5 | 0.030`d |
>225 | ±2 | 0.025`d |
H:Hardness of standard block `d:Indentation diameter(average)
Working Principle
Hardness is not a simple physical quantity, but a reflection of the
material elasticity, plasticity, strength and toughness .and
hardness test is the most simple mechanical testing method to
determine the metal material performance. Also one of the important
means to judge the products quality.
Brinell hardness test: Test force(F) is on the steel ball with
certain diameter(D) , pressed on sample surface. After a period of
time, cancel the force. The indentation diameter is get by
measuring with micrometer ocular,thus to calculate the average
pressure(N/mm²).Then we can get the Brinell hardness of the sample
as below:
Tips:F—Test force on steel ball,unit:N
D—Diameter of steel ball ,unit:mm
d—Indentation diameter,unit:mm
0.102—Rule coefficient
Features
- Suitable for measuring the surface is more rough cast iron, steel
and other non-homogeneous specimen Brinell hardness;
- The use of automatic closed-loop pressure sensor control system,
can dynamically reflect the loading process load changes.
- Modeling novel, strong structure,high reliability and operability ,
intuitive, high test efficiency;
- Equipped with excellent performance of the carbide indenter, high
hardness, wear resistance, good toughness, while high temperature,
corrosion resistance, to ensure that the instrument measured
standard, stable and reliable;
- Support Brinell, Rockwell, Vickers and other hardness standard
conversion;
- LCD liquid crystal display screen , menu intelligence tips, easy to
operate
- Compliance with ISO 6506, ASTM E10-12, ASTM E-384, GB / T231.2, JIS
Z2243 and other relevant domestic and foreign standards.
Brand reputation
The cetificate of CE,GOST,ISO9001 and etc..
Applied condition
- Cast iron, steel, non-ferrous metals, soft alloy of metal material
- Hard plastic, bakelite and some nonmetallic material.
Application field
- Metal processing industry quality control links
- Universities teaching and demonstration test
- The failure test of metal material
- The material hardness test of scientific research institutions
Working conditions
- Working Temperature:18℃~28℃;
- Relative Humidity:≤65%;
- Clean environment, no vibration;
- No corrosive media around.
Configuration
Standard Configuration | No. | Item | Quantity | Note |
1 | Main body | 1 | |
2 | 20×Lens | 1 | |
3 | φ2.5mm ball | 1 | |
4 | φ5mm ball | 1 | |
5 | φ10mm ball | 1 | |
6 | Small testing table | 1 | Diameter 80mm |
7 | Large testing table | 1 | Diameter 200mm |
8 | V-shape testing table | 1 | For cylindrical sample |
9 | Standard Hardness Block HBW/3000/10(150-250) | 1 | |
10 | Standard Hardness Block HBW/1000/10(75~125) | 1 | |
11 | Standard Hardness Block HBW/187.5/2.5(150-250) | 1 | |
12 | Fuse wire(2A) | 3 | |
13 | RS232 Cable | 1 | |
14 | Power line | 1 | |
15 | Plastic dust cover | 1 | |
16 | Attached files | 1 | |
17 | Instrument case | 1 | |
Optional Configuration | 1 | Brinell measurement system | 1 | |
Maintenance and care
- Each technical requirement of the instrument has already reached
the national standards before leaving factory. But its disassembly,
transportation or voltage after delivery might cause some data in
the instrument changed. So to make the electronic component in
normal operation to reduce the testing error, you can use test
force of 29400N(3000kgf) pressing times before starting the
instrument to eliminate the instrument deformation.
- The anti-interference component has been installed in the circuit
to ensure the transmission of the loading or unloading single of
the test force at all levels. At the same time, make sure no strong
interference source around when using the instrument, and power off
the instrument after finished the testing.
- All the screws and the caps have been fasten tightly before the
instrument leaving factory. However, the screw and cap may become
less crowded because that the screw lever for loading and unloading
are rotating all the time. If there is irregular noise, when the
screw lever rotating, please check and tightened the screw and cap
as the below figure shown.
Pulley and cap
- The instrument power supply shall be grounded reliably and equipped
with voltage-stabilizing device;
- If there is some slight noise during loading or unloading, it is
the loading mechanism making adjustment automatically, which is a
normal phenomenon.
- The instrument screw level and other movable surface should be
lubricated regular.
- When not in use for a long time, please cover the dust cover to
prevent dust into the instrument interior. And the hardness block,
indenter should be coated with antirust oil to prevent rusting
after using.
- Start using again after long time idling, please make testing after
preheating the electrical components.
- The accuracy of the reading microscope has been adjusted before
leaving factory. It is prohibited to disassembly without
authorization. Otherwise, it will reduce the reading accuracy of
the micro eyepiece.
- The storage and using of the reading microscope should avoid dust,
damp and corrosive gas environment;
- If there is dirt on the surface of the reading microscope lens,
please wipe it with soft absorbent cotton or lens paper. If there
is oil pollution, please wipe it slightly by the absorbent cotton
with industrial alcohol or ether.
- Don’t disassemble the instrument without authorization, maintenance
related matter, please contact MITECH after-sale service department
with 4000600280.