MT-1B Intelligent Portable Magnetic Particle Flaw Detector for outdoor use with high sensitivity

 

Product Overview

MT-1B magnetic particle flaw detector adapts high-capacity lithium battery pack, converse DC to AC through variable-frequency, providing magnetic powder flaw detector with magnetic power supply. With low power consumption, it can continuous work more than four hour after charging. It especially suits for working in the wild and aerial area.

Function & Application

It is widely used in the industry of aircraft manufacturing, boiler and pressure vessel, electric, oil field, shipbuilding, turbine and combustion engine parts, mine, machinery, standard parts, oil pump, vehicle parts, bridging, chemical, railway, large mechanical components, steel structure equipment etc. It mainly detects the surface detection of forging, quenching, welding, fatigue, for example, irregular workpiece of chain, crankshaft, bearing, high strength bolt, spring, forging, petrochemical pipe, valve, vane, gear, anchor chain, welding seam etc.

 

Working Conditions

Operatiom temperature: -10℃~+40℃
Storage temperature: -20℃~+70℃

Relative Humidity: ≤80%
The environment should avoid strong vibration, magnetic interference, corrosive medium and heavy dust.

 

Operating Method and Attention

Connect the line with detector, start the detector, press detection, choose proper polar distance according to the workpiece.

When making dry powder detection, put the powder on the workpiece, move the yoke with 40mm/s, make sure they are well connected, observe whether the powder is pile up.

When detecting, there must be overlap, the overlap area should less than 25mm, judge the marks correctly.

If the pile up is appeared, blow the redundant powder, make the mark clear.

Hot Products

Product Overview MITECH MU200 non-destructive ultrasonic hardness tester, based on the principle of ...
Mitech MSW20 Series Digital Display Webster Hardness Tester MSW-20,MSW20a,MSW-20bwith portable ...
Mitech MHBRVU-187.5 II Advanced Optical Hardness Tester Overview Mitech MHBRVU-187.5II advanced ...
Mitech MHBRVS-187.5 Digital Brinell Rockwell & Vickers Hardness Tester Overview Mitech MHBRVS-187.5 ...
Mitech MHRS-150 Digital Rockwell Hardness Tester Overview Mitech MHRS-150 Digital Rockwell Hardness ...
Mitech MHRS-150-P Digital Plastic Rockwell Hardness Tester Technical Parameters Technical specificat...