Home Companies Mitech CO.,LTD.

Directly Measuring Ultrasonic Thickness Tester With 100 Groups Memory MT600

Mitech CO.,LTD.
Active Member

Contact Us

[China] country

Address: Room E506, YingChuangDongLi Park, 1# of ShangDi East Road, Haidian District, Beijing, China

Contact name:Lareina Lee

Inquir Now

Mitech CO.,LTD.

Directly Measuring Ultrasonic Thickness Tester With 100 Groups Memory MT600

Country/Region china
City & Province beijing beijing
Categories Electric Wrenches
InquireNow

Product Details

Measuring Principle

The ultrasonic thickness gauge determines the thickness of a part or structure by accurately measuring the time required for a short ultrasonic pulse generated by a transducer to travel through the thickness of the material, reflect from the back or inside surface, and be returned to the transducer. The measured two-way transit time is divided by two to account for the down-and-back travel path, and then multiplied by the velocity of sound in the material. The result is expressed in the well-known relationship:

Where:H-Thickness of the test piece.

v-Sound Velocity in the material.

t-The measured round-trip transit time.

 

Specifications

Multi-mode

Pulse-Echo mode and Echo-Echo mode

Three working modes

normal mode, scanmode and diff mode

Units

Metric and Imperial unit selectable

Resolution0.1mm/0.01mm/0.001mm
Measuring Range0.65-600mm( P-E), 3-100mm (E-E)

 

 Transducer Technical Parameters

Model

Freq

MHz

Φ mmMeasuring RangeLower limitDescription
N022.514

3.0mm~300.0mm(In Steel)

40mm (in Gray Cast Iron HT200)

20mmfor thick, highly attenuating, or highly scattering materials
N05510

1mm~600.0mm

(In Steel)

Φ20mm×3.0mm

Normal Measurement

 

N05

/90°

510

1mm~600.0mm

(In Steel)

Φ20mm×3.0mmNormal Measurement
N0776

0.65mm~200.0mm

(In Steel)

Φ15mm×2.0mmFor thin pipe wall or small curvature pipe wall measurement
HT5512

1~600mm

(In Steel)

30mmFor high temperature (lower than 300℃) measurement.
P5EE510

P-E: 2~600mm

E-E: 2.5~100mm

Φ20mm×3.0mm

Normal Measurement

and trough-coating thickness testing

 

 Configuration

 

 NoItemQty.Note
            Standard Config.1Main body1 
2Probe P5EE(5MHz)1 
3Couplant1 
4Instrument Case1 
5Operating manual1 
6Alkaline battery2AA size
7Data Pro Software1 
8USB Cable1 
             Optional Config.1Probe N02 (2.5MHz) See Table1.1
2Probe N05/90°(5MHz) 
3Probe N05 (5MHz) 
4Probe N07(7MHz) 
5Probe HT5(5MHz) 

Operating Conditions

  • Operating Temperature: 0℃~+50℃;
  • Storage Temperature:-20℃~+70℃
  • Relative Humidity ≤80%;

The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. 

 

Hot Products

Product Overview MITECH MU200 non-destructive ultrasonic hardness tester, based on the principle of ...
Mitech MHBRVU-187.5 II Advanced Optical Hardness Tester Overview Mitech MHBRVU-187.5II advanced ...
Mitech MHBRVS-187.5 Digital Brinell Rockwell & Vickers Hardness Tester Overview Mitech MHBRVS-187.5 ...
Mitech MHRS-150 Digital Rockwell Hardness Tester Overview Mitech MHRS-150 Digital Rockwell Hardness ...
Mitech MHRS-150-P Digital Plastic Rockwell Hardness Tester Technical Parameters Technical specificat...
Mitech MHRS-150T Cantilever Rockwell Hardness Tester Overview Mitech MHRS-150T Cantilever Rockwell ...