Home Companies Lanry Instruments (Shanghai) Co., Ltd.

Inserted Type Transit Time Flow Meter TF1100-EI With High Temperature Sensor

Lanry Instruments (Shanghai) Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8 Floor, Block C, Bldg 5, No.2800 Jiuxin Rd., Songjiang District, Shanghai,201612, China

Contact name:Tracy Xu

Inquir Now

Lanry Instruments (Shanghai) Co., Ltd.

Inserted Type Transit Time Flow Meter TF1100-EI With High Temperature Sensor

Country/Region china
City & Province shanghai shanghai
Categories Laser Pointers
InquireNow

Product Details

Insertion type transit time water flow meter TF1100-EI with high temperature sensor
 
 
Compared with peers' products, our High-precision Insertion type transit time water flow meter TF1100-EI is a reliable and absolute matured achievement in high accuracy measurement. The power consumption dropped to very low, with a large screen 4- lines display full English or customized languages menu and easy to use, support 16G SD card data acquisition and serial data download.
 
Insertion type transit time water flow meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
Insertion type transit time water flow meter TF1100-EI with high temperature sensor Features:
 
1. Hot-tapped installation, no pipe line flow interrupted
2. Wide liquid temperature range: -35℃~200℃.
3. Wide bi-directional flow range of 0.01 m/s to 12 m/s..
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Data logger function for insertion ultrasonic flow meter

 

Application
 

General
● Service and maintenance

● Replacement of defective devices

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

 
 

Specifications:Transmitter

 

Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
Housing materialFiberglass
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Size244*196*144mm
Weight2.4kg

 

Specifications:Transducer

 

Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter rangeDN65-6000
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Cable LengthStd: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output 

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Hot Products

Ultrasonic insertion type flow meter Meter With 4-20mA Output insertion sensor Ultrasonic insertion ...
Insertion type transit time water flow meter TF1100-EI with high temperature sensor Compared with ...
Portable transit time flow meter TF1100-EP portable clamp on flow meter: Portable transit time flow ...
Clamp on type ultrasonic flow meter TF1100-EC by transit-time principle Clamp on type ultrasonic ...
Non-invasive transducers no pipe cutting Wall-mounted Transit Time Ultrasonic Flow Meter The Transit ...
Non-invasive easy to install Wall-mounted Transit-Time Ultrasonic Flowmeter The Transit Time ...