Home Companies Guangdong Uchi Electronics Co.,Ltd

Pentair 471566 Thermistor Probe Replacement NTC Temperature Sensor 10KOhm For Pool Spa Pump and Heater

Guangdong Uchi Electronics Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN

Contact name:Anna

Inquir Now

Guangdong Uchi Electronics Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Pentair 471566 Thermistor Probe Replacement NTC Temperature Sensor 10KOhm For Pool Spa Pump and Heater

Country/Region china
City & Province dongguan guangdong
Categories Ice Tongs
InquireNow

Product Details

 

Pentair 471566 Thermistor Probe Replacement NTC Temperature Sensor 10KOhm For Pool Spa Pump and Heater

 

 

Description

 

471566 Probe Thermistor Used On Pentair Minimax NT Heaters. Brass Temp Sensor Screws Into Header, with High Temp Yellow Connection Cable/Wire. Fits Pentair Minimax NTD Electronic Heaters. Also Fits Ultratemp and ThermalFlow Heaters By Pentair. Not Used On Purex Minimax or Minimax Plus Heaters. 471566 Can also be found on Minimax Parts Pages

 

 

Actual product images

 

 

 

Application

 

This thermistor probe is designed to use with Pentair MiniMax NT STD, NT LN, NT TSI pool and spa heater models 200, 250,

300, 400 and also compatible with UltraTemp and ThermalFlo pool and spa heat pumps. Measures 1-inch length by 2-inch

height by 1-inch width.

Used on the following models:
MiniMax NT STDused in Model Nos., 200, 250, 300, 400.
MiniMax NT TSIused in Model Nos., 200, 250, 300, 400.
MiniMax NT LNused in Model Nos., 200, 250, 300, 400.
ThermalFlo Heat Pump
UltraTemp Heat Pump

 

 

 

 

Main Specification

 

Part NumberNSB0103FC2-152T6C
Amazon OE#471566
Resistance @25C10KOHM
Cable Length150mm
Cable ColorYellow
HousingBrass- Thread
MOQ500PCS
Lead time 7-10 workdays

 

 

Outgoing inspection 

 

NOItemTechnical requirementsTest conditions and method
5-1.High temp. Test

DR/R25£±3%

 

DB/B£±3%

 

No change with withstand voltage,

Insalution performance.

Appearance without damage.

105±5℃,1000±24 hrs
5-2.Low temp. tes-30±5℃,1000±24 hrs
5-3.Endure moisture testStore in environment 65±2℃,90%-95%RH for 1000±24 hrs
5-4.Temp. cycle testPlace the sample in -30℃ for 10 min, in 25℃ for 10 min and in 100 ℃ for 10 min. and repeat for 5 times.
5-5Tensile tests

After tensile test, the sensor should be

no damage and no falling.zero power

resistance change rate should be less

than ±1% in 25℃

Clamp wire at 50mm away from the inner edge of the connector terminal, then put 10N static tension between terminal and wire for 1min, along axial direction.after the test, check if there is any borken wire, falling off or damage and measure zero-power re.
5-6Drop test

No technical damage. zero power

resistance change rate should be less than ±1% in 25℃

Drop the sensor from a meter high through axial and lateral direction to cement floor, each direction for 5 times.then check the appearance and measure zero-power resistance in 25℃
5-7Vibration testFrequency range:10-500HZ,accelerated speed:10g,frequency sweep time: both X and Y for 30 min.recover for 4 hours after test, visual inspect the appearance of the sensor and measure zero- power resistance in 25℃

 

 

6,Storage Method

6.1 In the process of storage and transportation, per stack height is not more than 4 CTN products.

6.2 Available with all transport method, but avoid the rain, snow of direct or indirect leaching and mechanical damage.

6.3 Products should be stored in the temperature of environment - 10 ℃ / + 40 ℃, relative humidity is not more than 80%, environment should not have acid, alkali and corrosion gas or radioactive source.

 

7,Attention on operation

7.1 It will bring extra heat and affect testing precision when the current pass through the sensor, With a view to it before selecting sensor.

7.2 When the product moves, the installation must be handled gently to avoid damage caused by pulling the product.

7.3 Product deformation, oxidation and other phenomena, can not be used, so as not to affect the temperature accuracy.

7.4 Excessive temperature variations should be avoided within the operating temperature range.

7.5 Do not use in corrosive gases (such as CO2,NH3,SOX,NOX, etc.) beyond specified conditions.

7.6 Do not use in electrolysis, salt, acid, alkaline and organic solvents beyond specified conditions.

7.7 In the limit temperature, the product can withstand too high or too low temperature shock in the short term, but can not put the product in the limit temperature for a long time, in order to avoid shortening the service life of the product.

If you need any help, please consult our sales staff or engineers, thank you!

Hot Products

Micro Rotary Compressor With 500W Cooling Capacity Application In Refrigeration Equipment Capacity ...
Low Noise And Vibration Micro Rotary Compressor With 500W Cooling Capacity ​ Compressor Type ...
34S Square 220v High Power MOV Varistor High Energy Absorption Capability 34S Square 220V high power ...
34S Square 220v High Power MOV Varistor High Energy Absorption Capability 34S Square 220V high power ...
34S Square 220v High Power MOV Varistor High Energy Absorption Capability 34S Square 220V high power ...
34S Square 220v High Power MOV Varistor High Energy Absorption Capability 34S Square 220V high power ...