Home Companies Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Steam To Water U Titanium Heat Exchanger , Lightweight Shell And Tube Exchanger

Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Active Member

Contact Us

[China] country

Address: No.18, Yinhu Development Zone, Dongxihu District Wuhan China

Contact name:Nichole Deng

Inquir Now

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Steam To Water U Titanium Heat Exchanger , Lightweight Shell And Tube Exchanger

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

Steam to Water Tube Heat Exchanger

 

Water - Cooled Evaporator

 

The main control parameters of the shell and tube heat exchanger are heating area, hot water flow, heat

 

transfer, heat medium parameters.

 

1), according to the known cold and hot fluid flow, the initial temperature and the specific heat capacity of

 

the fluid to determine the required heat transfer area. The initial estimated heat transfer area, generally

 

assumed the heat transfer coefficient, to determine the heat exchanger structure, and then check the

 

heat transfer coefficient K value.

 

2), the choice of heat exchanger should pay attention to pressure levels, the use of temperature, interface

 

connection conditions. In the pressure drop, the installation conditions allow the premise, the shell and

 

tube heat exchanger to choose a small diameter of the lengthened, is conducive to improving the heat

 

transfer.

 

3), the heat exchanger pressure drop should not be too large, generally controlled between 0.01 ~

 

0.05MPa;

 

4), the flow rate should be considered the size of the fluid viscosity, viscosity flow rate should be less than

 

0.5 ~ 1.0m / s; general fluid tube flow rate should take 0.4 ~ 1.0m / s; easy to scale the fluid should take

 

0.8 ~ 1.2m / s The

 

5), high temperature water into the heat exchanger should be set before the filter.

 

6), the heat exchanger in a single heat treatment and configuration of the number of combinations of the

 

results should meet the heat exchange station total heating load and regulation requirements. To meet

 

the requirements of the user heat load adjustment under the premise of the same heating coefficient of

 

the number of heat exchangers should not be less than 2, not more than 5 units.


 

STEAM TO WATER HEAT EXCHANGER

 

CAPACITY: 1000KW TO 4000KW

 

ModelCapacity (KW)Dimension (mm)Weight (kg)
DT1TACEFH1H2
QXSW60S10100027316002053120360150100350240297
QXSW70S12125032520322498150406180120350240357
QXSW80S12140032520322498150406180120350240372
QXSW90S12160032520322498150406180120350240387
QXSW100S12180032520322498150406180120350240412
QXSW120S14210035520322555150440180120400290494
QXSW140S14250035525003023180440180120400290517
QXSW180S16320042625002951180530260150260260729
QXSW220S16400042625002951180530260150260260784

 

ModelS1S2W
SpecificationConnection typeSpecificationConnection typeSpecificationConnection type
QXSW60S10DN100male flangeDN65male flangeDN80male flange
QXSW70S12DN100male flangeDN65male flangeDN80male flange
QXSW80S12DN125male flangeDN80male flangeDN100male flange
QXSW90S12DN125male flangeDN80male flangeDN100male flange
QXSW100S12DN125male flangeDN80male flangeDN100male flange
QXSW120S14DN125male flangeDN80male flangeDN100male flange
QXSW140S14DN125male flangeDN80male flangeDN100male flange
QXSW180S16DN150male flangeDN100male flangeDN125male flange
QXSW220S16DN150male flangeDN100male flangeDN125male flange

 

WATER TO WATER HEAT EXCHANGER

 

CAPACITY: 500KW TO 3500KW

 

ModelCapacity (KW)Dimension (mm)Weight (kg)
DT1TACEFH1H2
QXWW35S1050027312701723120360150100350240200
QXWW50S1070027316002053120360150100350240237
QXWW70S12100032520322498150406180120350240322
QXWW100S12150032520322498150406180120350240367
QXWW140S14200035525003023180440180150400290512
QXWW170S16250042625002951180530260150310310693
QXWW200S16300042625002951180530260150310310736
QXWW240S16350042625002951180530260150310310795

 

ModelW1W2
SpecificationConnection typeSpecificationConnection type
QXWW35S10DN80male flangeDN80male flange
QXWW50S10DN80male flangeDN80male flange
QXWW70S12DN100male flangeDN100male flange
QXWW100S12DN100male flangeDN100male flange
QXWW140S14DN100male flangeDN100male flange
QXWW170S16DN125male flangeDN125male flange
QXWW200S16DN125male flangeDN125male flange
QXWW240S16DN125male flangeDN125male flange

 

 

 

COOPERATED CLENTS
 

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...