Home Companies Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Refrigeration Industry Stainless Steel Heat Exchanger , Water Cooling Heat Exchanger

Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Active Member

Contact Us

[China] country

Address: No.18, Yinhu Development Zone, Dongxihu District Wuhan China

Contact name:Nichole Deng

Inquir Now

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Refrigeration Industry Stainless Steel Heat Exchanger , Water Cooling Heat Exchanger

Country/Region china
City & Province wuhan hubei
Categories Refrigeration & Heat Exchange Parts
InquireNow

Product Details

316L Stainless Steel Tube Heat Exchanger

 

Water - Cooled Evaporator

 

316L Stainless Steel Tube Heat Exchanger Water - Cooled Evaporator is suitable for water cooled unit,

 

water source heat  pump, air cooled pump and air cooled heat pump unit.
 
The product is applying for refrigerants of R22, R134a, R407C and R410A etc.
 
The referigerating medium is for tap water, underground water, river water and sea water or brine, water
 
and glycol solution, sulfate solution, etc.
 
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,
 
etc.
 
The shell raw material mainly are seamless steel tube, stainless steel pipe.

 
1, Heat exchange tube: four main tube type.
 
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
 
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
 
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry
 
evaporator.
 
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry
 
evaporator.
 
2, shell raw material:
 
There are two of the major materials:
 
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
 
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than
 
40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
 
3, interface:
 

FULL LIQUID TYPE EVAPORATOR AND CONDENSER EXTERNAL OIL (DOUBLE CIRCUIT)

 

CAPACITY: 2400KW TO 4000KW

 

Models  QX-2400MQX-2650MQX-2900MQX-3200MQX-3500MQX-3750MQX-4000M
Refrigerant R22 (or other environmental refrigerants) Refrigerating capacity (KW)2400265029003200350037504000
Heating capacity (KW)3000340037503850400043504500
Wam3/h413456.5499.6550.6602.3646688.5
Wbm3/h516571624670700750773
Dpnbar0.850.870.870.760.790.820.84

 

ModelsQX-2400MQX-2650MQX-2900MQX-3200MQX-3500MQX-3750MQX-4000M
Dimension(mm)A4845484548454845503550355035
A1550550550550550550600
A2450450450450450450500
L12500250025002500269026902690
B1570157016701670167016701670
B1805805855855855855905
C11058105811081108110811081158
C21058105811081108110811081158
D1566566616616616616666
D2616616666666666666766
H1420420420420500500550
H2420420420420500500550

Inlet/Outlet (diameter)

Connection

a/b(DN)250250250250250250300
c1-4 (mm)54545454545454
d1-2(mm)105105105105105105105
D3-4(mm)80929292929292
Corresponding external oilVolume (L)200*2210*2220*2240*2250*2270*2300*2
WeightP (KG)3820425546105080555060706900

Notes: Wa water flow capacity of evaporator Wb water flow capacity of condenser Dpn circulating cooling water

Refrigerating work position: evaporating temperature 5°C, condensing temperature 34°C, chilled water inlet temperature 12°C and outlet 7°C, cooling water inlet temperature 18°C and outlet 29°C

Heating work position: evaporating temperature 4.5°C, condensing temperature 50°C, hot water inlet temperature 40°C and 45°C, heat source water inlet temperature 16°C and 7°C.

 

WATER TO WATER HEAT EXCHANGER

 

CAPACITY: 500KW TO 3500KW

 

ModelCapacity (KW)Dimension (mm)Weight (kg)
DT1TACEFH1H2
QXWW35S1050027312701723120360150100350240200
QXWW50S1070027316002053120360150100350240237
QXWW70S12100032520322498150406180120350240322
QXWW100S12150032520322498150406180120350240367
QXWW140S14200035525003023180440180150400290512
QXWW170S16250042625002951180530260150310310693
QXWW200S16300042625002951180530260150310310736
QXWW240S16350042625002951180530260150310310795

 

ModelW1W2
SpecificationConnection typeSpecificationConnection type
QXWW35S10DN80male flangeDN80male flange
QXWW50S10DN80male flangeDN80male flange
QXWW70S12DN100male flangeDN100male flange
QXWW100S12DN100male flangeDN100male flange
QXWW140S14DN100male flangeDN100male flange
QXWW170S16DN125male flangeDN125male flange
QXWW200S16DN125male flangeDN125male flange
QXWW240S16DN125male flangeDN125male flange

 

 

COOPERATED CLENTS
 

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...