Home Companies Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Baffle Plate U Tube Bundle Heat Exchanger For Industrial Refrigeration

Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Active Member

Contact Us

[China] country

Address: No.18, Yinhu Development Zone, Dongxihu District Wuhan China

Contact name:Nichole Deng

Inquir Now

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Baffle Plate U Tube Bundle Heat Exchanger For Industrial Refrigeration

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

Straight Tube Baffle Plate Water - Cooled

 

Shell and Tube Heat Exchanger

 

A group of tubes or coils are housed in a housing consisting of heat exchangers. The heat transfer of the

 

two media, one in the tube, the other in the tube shell, through the wall of heat transfer, usually horizontal.

 

The capacity and heat exchange area of the new condenser are calculated as follows: Heat exchange

 

area (m2 = 3.1416 × tube diameter × tube length × total number of tubes. The size of the new condenser

 

should be selected according to the amount of medium to be condensed per unit time Size to set.

 

The use of tube bundle to make the cooling medium flow rate is better, so more energy efficient

 

(1) the design of the program: the given or selected process, the main equipment of the type of brief

 

discussion.

 

(2) the process design calculation (including computer aided calculation) of the main equipment: material

 

balance, energy measurement, process parameter selection, equipment structure design and process

 

size design calculation.

 

(3) the selection of auxiliary equipment: the typical auxiliary equipment, the calculation of the main process

 

size, equipment specifications, model selection.

 

(4) process flow chart: the form of a single-line drawing, marked the main equipment and auxiliary

 

equipment, material direction, logistics, energy flow, the main

 

To measure the point.

 

(5) the technical conditions of the main equipment diagram: the surface should include the equipment of

 

the main process size, technical characteristics of the table and take over the table.


 

STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR

 

CAPACITY: 310KW TO 680KW

 

Models  RE310S10RE360S12RE420S12RE470S12RE540S14RE620S14RE680S14

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW310360420470540620680
Kcal/h(×103 )267317361404464533585
Wnm3 /h53.36272.280.893107116
Wmm3 /h687081.7100105140145
Dpnbar0.430.430.350.460.410.470.49

 

ModelsRE310S10RE360S12RE420S12RE470S12RE540S14RE620S14RE680S14
Dimension(mm)A140140150150150170170
B273273325325355377377
C2500169024001500269026902860
D360360406406440460460
E370370380380400400400
F2586258624882586277627762946
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)100100125125125150150
D1(mm)35354242424242
D2(mm)67678080909090
P(kg)296380398442459654669

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


STRAIGHT SINGLE SERIES DRY SPIRAL BAFFLE PLATE EVAPORATOR (DOUBLE SYSTEM)

 

CAPACITY: 320KW TO 680KW

 

Models  RE320D10RE360D12RE420D12RE470D12RE540D14RE620D14RE680D14

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW320360420470540620680
Kcal/h(×103 )267317361404464533585
Wnm3 /h53.36272.280.893107116
Wmm3 /h687081.7100105140145
Dpnbar0.430.430.350.460.410.470.49

 

ModelsRE320D10RE360D12RE420D12RE470D12RE540D14RE620D14RE680D14
Dimension(mm)A140140150150150170170
B273273325325355377377
C2500169024001500269026902860
D360360406406440460460
E370370380380400400400
F2586258624882586277627762946
VentS11/21/21/21/21/21/21/2
OutletS21/21/21/21/21/21/21/2
ConnectionW(DN)100100125125125150150
D1(mm)35354242424242
D2(mm)67678080909090
P(kg)296380398442459654669

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 40RT TO 60RT

 

ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACE
QXC40S104015.12273160017501202738517231
QXC45S104517.01273160017501202738518035
QXC50S105018.90273203221821202738520938.5
QXC55S105520.79273203221821202738521742.5
QXC60S106022.68273203221821202738522446

 

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)FPT(inner pipe thread)FPT(inner pipe thread)
QXC40S103/81-5/81-1/832-1/2
QXC45S103/81-5/81-1/832-1/2
QXC50S103/81-5/81-1/832-1/2
QXC55S103/81-5/81-3/832-1/2
QXC60S103/81-5/81-3/832-1/2

 

 

 

COOPERATED CLENTS
 

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...