Home Companies Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Single System Tube Heat Exchanger , Stainless Steel Heat Exchanger 18KW-4000KW

Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Active Member

Contact Us

[China] country

Address: No.18, Yinhu Development Zone, Dongxihu District Wuhan China

Contact name:Nichole Deng

Inquir Now

Wuhan Qiaoxin Refrigeration Equipment CO., LTD

Single System Tube Heat Exchanger , Stainless Steel Heat Exchanger 18KW-4000KW

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

Tubular Heat Exchanger Water - Cooled

 

Evaporator for Industrial Chiller


Tubular Heat Exchanger Water - Cooled Evaporator for Industrial Chiller is suitable for water cooled unit,

 

water source heat pump, air cooled pump and air cooled heat pump unit.
 
The product is applying for refrigerants of R22, R134a, R407C and R410A etc.
 
The referigerating medium is for tap water, underground water, river water and sea water or brine, water
 
and glycol solution, sulfate solution, etc.
 
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,
 
etc. The shell raw material mainly are seamless steel tube, stainless steel pipe.

 
1, Heat exchange tube: four main tube type.
 
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
 
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
 
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry
 
evaporator.
 
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry
 
evaporator.
 
2, shell raw material:
 
There are two of the major materials:
 
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
 
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than
 
40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
 
3, interface:
 

U SHAPED TUBE DRY EVAPORATOR (DOUBLE SYSTEM)

 

CAPACITY: 35KW TO 95KW

 

Models  QXU35D6QXU47D6QXU56D6QXU65D8QXU80D8QXU95D8

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW354756658095
Kcal/h(×103 )30.240.448.256.768.881.7
Wnm3 /h689.611.413.816.4
Wmm3 /h1011.41214.51921
Dpnbar0.270.410.350.390.420.46

 

ModelsQXU35D6QXU47D6QXU56D6QXU65D8QXU80D8QXU95D8
Dimension(mm)A127514071431143116311781
B168168168168219219
C107107161161200200
D104011901030118013801530
E200200200240240240
VentS11/21/21/21/21/21/2
OutletS21/21/21/21/21/21/2
ConnectionW(DN)505050506565
D1(mm)161622222222
D2(mm)222235353535
P(kg)72788893125136

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)

 

CAPACITY: 120KW TO 270KW

 

Models  QXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10

Rated data

Refrigerant R22

ti=12°C te=2°C

tu=7°C Dts=5°C

QnKW120135155185220270
Kcal/h(×103 )103.2116133.3159180232
Wnm3 /h20.323.226.731.837.846.4
Wmm3 /h252830414365
Dpnbar0.410.440.370.360.430.42

 

ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10
Dimension(mm)A181521152315232026542654
B219219219273273273
C180180180200234234
D153018302030200022802280
E240240240300300300
VentS11/21/21/21/21/21/2
OutletS21/21/21/21/21/21/2
ConnectionW(DN)808080100100100
D1(mm)353535353535
D2(mm)545467678080
P(kg)145155163232279289

Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

Dpn-pressure drop of recirculating cooling water Dts-overheat temperature

 

CONDENSER SERIES SINGLE CIRCUIT

 

CAPACITY: 3RT TO 15RT

 

ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
DT1TACE
QXC3S431.1341146357217514070232.5
QXC5S551.8901406357217516570334
QXC8S683.0241687628589018592496.5
QXC10S6103.78016895310499018592587.8
QXC12S6124.53616895310499018592629.6
QXC15S6155.67016812701366100185927511.6

 

ModelS (Vent)

P (fluoride inlet)

Copper pipe diameter (inch)

L(fluoride outlet)

Copper pipe diameter (inch)

W (standard port)W (optional port)
FPT(inner pipe thread)FPT(inner pipe thread)FPT(inner pipe thread)
QXC3S41/45/85/813/4
QXC5S51/45/85/81-1/21
QXC8S61/47/85/81-1/21
QXC10S61/47/85/81-1/21
QXC12S61/41-1/87/81-1/21
QXC15S61/41-1/87/81-1/21

 

 

 

 

COOPERATED CLENTS

Hot Products

Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
RCS748-2 Condenser Seawater condenser Water Chiller Unit condensing Super corrosion and anti-aging ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...
Industrial condenser water cooled condenser units nickel copper tube condenser 1, Introduction: (1) ...