Home Companies TRW Medical Instrument Co.,Ltd

Laparoscopic Ultrasonic Scalpel System Surgery Equipment 250V

TRW Medical Instrument Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Room 406, No. 2, Qilin Building C, No. 53, Middle Section of Huangshan Avenue, Yubei District, Chongqing.

Contact name:Huang

Inquir Now

TRW Medical Instrument Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Laparoscopic Ultrasonic Scalpel System Surgery Equipment 250V

Country/Region china
City & Province chongqing chongqing
Categories Air Purifier
InquireNow

Product Details

Coagulation ability and Tissuesensing technology Ultrasonic Scalpel System Laparoscopic
 
Products Description
 
• Suitable for cutting, coagulation, grasping and separation of various tissues. open or endoscopic surgery
• ENT: tonsillectomy, parotid tumor resection
• Head and Neck Surgery: Thyroidectomy, Neck Dissection
• Breast surgery: mastectomy, lumpectomy, axillary ,lymphadenectomy
• Hepatobiliary Surgery: gallbladder, appendix surgery, liver surgery
• Thoracic surgery: radical resection of
esophageal cancer, radical resection of lung cancer, mediastinal surgery
• Gastrointestinal surgery: gastric cancer, colorectal,
pancreaticoduodenal surgery, hemorrhoid surgery
• Gynecology: adnexectomy, total hysterectomy, pelvic lymph node dissection
• Urology: minimally invasive surgery, renal cystectomy, adrenalectomy, radical ystectomy
 
 
Product name                    Model                                                             Specification (only for cutter)


 
Cutter head 1QUHS14S,QUHS23S,QUHS36S.142,326
Cutter head 2QUHS14S,QUHS23S,QUHS36S45
GeneratorK500. 
HandleQUHP35 
Foot switchQFS-029(optional) 
Product-combination kit
Ultrasonic knife+generator
Ultrasonic knife +handle
Ultrasonic knife +cutter head
Ultrasonic knife+cutter head
 

I.Composition of ultrasonic cutting hemostasis knife system

The system is mainly composed of five parts:generator (K500), handle (QUHP35), cutter head (QHS14S, QHS23S and QHS36S), foot switch (QFS - 02 optional) and trolley (C100 optional).
It is the control section of ultrasonic scalpel system and its output power can be controlled by handle and foot switch.
The output power can be divided into 5 levels, of which level 1 is the minimum and level 5 is the maximum.
Ultrasonic scalpel in level 5 will show relatively strong separation capacity.
ultrasonic scalpel in level 1 will show relatively strong hemostasis capacity.

II.Profile

1.Generator                                                                                                                                                                                                                     The main function of the generator is to provide electrical energy of ultrasonic frequency, and control the output of electrical energy to the handle transducer by activating the foot switch or the handle switch. Set the output energy through the front panel operation of the generator, and observe the working state of the system. Different gears provide different energy. The system generator model is K500.
 
 
Ultrasonic Scalpel System
•The input voltage:Ac 90V to 240V
•Input frequency:50 / 60Hz
•Working current:3A
•Driving frequency:55.5KHz
•The power consumption of the largest:300 VAs.
 
2.Handle
There is an electroacoustic transducer in the handle, which can convert the electrical energy provided by the generator into precise mechanical motion(ultrasonic vibration). The transducer is connected to the ultrasonic horn;The horn amplifies the motion generated by the transducer. The handle receives the electric energy from the generator and transfers it to the cutter head through accurate and controllable mechanical movement. System handle model: QUHP35

 

                        3.Cutter head                                                                                                                                                                              Mechanical motion is transferred from the handle to the tip, while ultrasound energy is transferred to hemostasis or coagulation and cutting of tissue. The tip is a sterile single-use medical device that is disposed of after use and cannot be sterilized for reuse (human market). The tips are sterilized by ethylene oxide or cobalt-60 irradiation at the time of delivery; the irradiation sterilization is valid for four years, beyond the expiration date or if the sterilization package is damaged, the tips should be stopped immediately and scrapped or destroyed. The system can be equipped with QUHS14S, QUHS23S and QUHS36S. Operating frequency of the cutter head: 55.5 k Hz ±1 k Hz.
TRW-UK Series tool head with manual button, connected with the main machine, transducer, rotary knob and torque wrench integrated.
There are 4 types of cutter head according to the length of cutter: TRW-UK-14,TRW-UK-23,TRW-UK-36,TRW-UK-45.
Compatible host:
RXCD-300
GEN04(Johnson & Johnson)
GEN11(Johnson & Johnson)
Disinfection method: support 134℃ high temperature.
4.Foot switch
Used to start or stop the output of ultrasound energy as soon as the pedal switch is pressed, the pedal will activate and transmit
information to the main generator. left pedal on foot switch is the switch of level 5 high power right one on foot switch is the
switch of level 1-4 power lower power with protection level of IPX8.
 
Comparison :
 

Hot Products

#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
Disposable Plastic Medical CE Surgical Supplies Clear Zsr Circumcision Stapler Device #detail...
Self Auto Manual Disposable Circumcision Stapler Foreskin Cutting Stapler Kits For Adult And ...
#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
Medical Quality Trustworthy Zsr Self Disposable Circumcision Stapler CE ISO13485 #detail_decorate...