Anastomosis Disposable Linear Cutter Stapler GST Echelon 60 Reloads

Country/Region china
City & Province chongqing chongqing
Categories Ostomy Supplies
InquireNow

Product Details

Single Use Powered Endo Linear Cutter Stapler and Reloads

The endoscopic linear cutter stapler with single use reloads are widely applied in lung, brochial tissue, stomach and intestines both in open and endoscopic surgery such as transection, resection and anastomosis.

 

Main Applications
Thoracic Surgery
> Thoracoscopic pulmonary bulla resection
> Throacoscopic lobotomy
Gastrointestinal Surgery
Laparoscopic Gastrectomy
>Laparoscopic resection of the colon
>Laparoscopic lower anterior resection
> LGBP
 
Product Advantage
The maximum unilateral bend Angle is 45 degrees, the steering mode is active turning, and the injury caused by high break tohuman tissue.
High suture strength, low forming defect rate of titanium nail, good striking force of instrument.
Single hand operation, one time back knife, more convenient operation, reduce the difficulty of operation, ensure the safety of operation.
•The unit has a single shot protection device, the used nail box cannot be fired twice.
A/B series guns and components can be universally fitted.
New olecranon design, visualization of used blood vessels, safer blood vessel dissection. •Single use to avoid cross-infection
Staple 2.0mm should not be used for tissue with a thickness less than 0.6mm after compression. or tissue and aorta properly compressed to 1.0mm thickness.
• Staple 2.5mm should not be used for tissue with a thickness less than 1mm after compression. or tissue and aorta properly compressed to 1.5mm thickness.
• Staple 3.5mm should not be used for tissue with a thickness less than 1.5mm after compression. or tissue and aorta properly compressed to 2.0mm thickness.
• Staple 4.5mm should not be used for tissue with a thickness less than 2.0mm after compression. or tissue and aorta properly compressed to 2.5mm thickness.
 
 

SpecificationsCartridge Length (mm)Shaft Length (mm)
ES190-60E90190
ES190-45E75190
ES250-60E90250
ES250-45E75250
ES350-60E90350
ES350-45E75350

 

•  Staple 2.0mm should not be used for 

 

 
 
Service: 
 We can accept OEM for any requirements

Hot Products

#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
Disposable Plastic Medical CE Surgical Supplies Clear Zsr Circumcision Stapler Device #detail...
#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1...
Medical Quality Trustworthy Zsr Self Disposable Circumcision Stapler CE ISO13485 #detail_decorate...
Specialized Safe Zsr Medical Manual Disposable Circumcision Stapler Foreskin Cutting Stapler Urology ...