Home Companies Xi'an Yunyi Instrument Co., Ltd

24V Concrete Magnetic Water Flow Meter Cement Grout

Xi'an Yunyi Instrument Co., Ltd

Contact Us

[China] country

Trade Verify

Address: Rm. 1203-1, Bldg. B, Xian Xinsilu International E-Commerce Industrial Park, No. 9, Gangwu Road, Int'l Port District

Contact name:Alice

Inquir Now

Xi'an Yunyi Instrument Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

24V Concrete Magnetic Water Flow Meter Cement Grout

Country/Region china
Categories Magnetic Materials
InquireNow

Product Details

Cement Grout concrete Magnetic Flow Meter

 

 

Description Cement Grout concrete Magnetic Flow Meter

Electromagnetic flowmeters use Faraday's law of induction to detect flow.

Inside the electromagnetic flowmeter there is an electromagnetic coil that generates a magnetic field, and electrodes that capture the electromotive force (voltage). It is because of this that electromagnetic flowmeters can measure flow when there seems to be nothing in the pipeline.

 

 

Parameter Cement Grout concrete Magnetic Flow Meter

Nominal Diameter(mm)
(Special specifications can be customized)
pipeline tetrafluoroethylene lining:DN10~DN2600
Pipeline rubber lining:DN40~DN2600
Flow direction:positive and negative, the net flow
Turndown ratio:1500:1
Repeatability error:

± 0.1% of measured value

 

Accuracy:Pipeline:0.5,1.0
Measured medium temperature:ordinary rubber lining::-20~+60℃
High-temperature rubber lining: -20~+90℃
PTFE lining:-30~+120℃
High temperature tetrafluoroethylene lining:::-20~+180℃

Rated working pressure:

(High voltage can be customized)

DN6-DN80:≤2.5MPa
DN100-DN250:≤1.6MPa
DN300-DN2600:≤1.0MPa
Flow rate range:0.1-15m/s
Conductivity range:the measured fluid conductivity≥5μs/cm
Current output:load resistance0~10mA:0~1.5kΩ
4~20mA:0~750 kΩ
Digital frequency output:

transistor output frequency limit can be set with optical isolation within 1 ~ 5000HZ bidirectional open-collector output. External power supply is turned ≤35V maximum collector current of 250mA

 

Power supply:AC220Vor DC24V
Length of straight pipe requirementsupstream≥5DN,downstream≥2DN
Connection:

are used between the meter and piping flange connection, flange dimensions shall comply with the provisions of GB11988

 

Explosion levelsmdIIBT4
Protection class:IP65,special order up to IP68
Ambient temperature:-25~+60℃
Relative humidity:5%~95%

Total power consumption:

 

less than 20W

Measurement range:

Inner diameter(mm)1015202532405065
Qmin(m3/h)0.02830.06360.120.1760.290.4520.71.19
Qmax(m3/h)4.249.5416.9626.543.4267.85106.0179.0
Inner diameter(mm)80100125150200250300350
Qmin(m3/h)1.82.824.416.3611.317.625.434.6
Qmax(m3/h)271.0424.0662.0954.01690265038105190
Inner diameter(mm)400450500550600700800900
Qmin(m3/h)45.257.277.685.5101.0138.0180.0229.0
Qmax(m3/h)67808570106001280015200207002710034300
Inner diameter(mm)10001100120014001600180020002200
Qmin(m3/h)282.0342.0407.0554.1732.7916.01131.01368.4
Qmax(m3/h)42400513006100083121108566137404169635205258

 

Select the lining material

Should be based on the measured medium temperature corrosive wear and to select the lining material

Lining materialcorrosion resistanceWorking temperatureApplication
NeGeneral resistance to low concentrations of acid salt corrosion-20~70℃lower industrial water effluent pH and salt concentration
POHas an excellent wear resistance, abrasion resistance slurry dedicated to strong, not decay-10~60℃Liquids containing solid particles (slurry pulp, etc.)
FEP

1 corrosion resistant and quite PTFE

2 high mechanical strength, good wear resistance

3 table smooth, easy adhesion precipitate

4 have strong abrasive media fluid good resistance to outside negative, anti-vacuum effect

-40~180℃except mortar. Like with PTFE can be used for drinks and other health requirements of the media
PTFElmost all of the corrosion resistant chemical media, poor wear resistance-40~180℃Not be used for pipes and wear strong negative fluid


 

 

Features Cement Grout concrete Magnetic Flow Meter

l Fully digital processing, anti-interference ability, reliable measurement, high accuracy flow measurement range up to 1500: 1

l Ultra-Low EMI switching power supply for supply voltage variation range, anti-EMI performance.

l 16-bit embedded microprocessors, computing speed, high precision, programmable low-frequency square wave excitation frequency and improve the stability of the flow measurement, low power consumption.

l No moving parts inside the pipe l, unimpeded flow of parts, measuring almost no additional pressure loss.

l range in the field can be modified online according to the actual needs.

l measurements and velocity distribution, the physical parameters of the fluid pressure, temperature, density, viscosity and the like.

l have RS485, RS232, Hart, and Modbus and other digital communication signal output. (Optional)

l total hourly recording function to record the total flow in units of hours for hourly metering system (optional)

l have three internal totalizer can show the cumulative amount of forward and reverse cumulative amount of the difference between the volume totalizer, the internal power-down features not always, can record 16 power-down times. (Optional)

l IR handheld operator, 115KHZ communication speed, long-distance non-contact operation of all functions converter (optional)

 

Hot Products

Pt124b-123 Rubber Extruder Melt Pressure Sensor Melt Pressure Transmitter Transducer Description ...
4-20ma 0.5-4.5V Water Pipe Pressure Sensor For Pressure Monitoring Description of 4-20ma 0.5-4.5V ...
Mini gas air silicon pressure sensor transducer 70mpa Description Mini gas air silicon pressure ...
Pressure Transducer Vs Pressure Transmitter For Water Cost Description Pressure Transducer Vs ...
manufactory 4-20ma Flush Diaphragm Pressure Transmitter Description manufactory 4-20ma Flush ...
Description Industrial silicon differential Piezoresistive Pressure Sensor YPS-19 is 316L SS ...