Specifications
Application: Temperature Sensors for Molten Metal
Wire:Pt-Rh/Wre
Tip:604/602
Rapid-response type expendable thermocouple is used for measuring
the temperature of molten metal.It has advantage of high
accuracy,rapid reaction,reliability and stability.
According the different thermocoupe wire,thermocouple has four type
are S,R,B,C,D Type.
Designation | Type | Model | Using range recommended (ºC) | Wire diameter(mm) |
PtRh10%-Pt | S | KS | 1760 | 0.05 |
PtRh13%-Pt | R | KR | 1760 | 0.05 |
PtRh30%-PtRh6% | B | KB | 1820 | 0.05 |
WRe5%-WRe26% | C | KC(KW5/26) | 1820 | 0.08 |
WRe3%-WRe25% | D | KD(KW3/25) | 1820 | 0.08 |
Accroding the different thermocouple connector,thermocouple tip can
be classified as 604 and 602 type.
Type | Model |
602(Round bottom) | KR/S/B/C/D-602 |
604(Triangle bottom) | KR/S/B/C/D-604 |
Accroding the different thermocouple wire tolerance,thermocouple
can be classified as common thermocouple wire(P) and precision
thermocouple wire(J).
Type | Model | Accuracy |
P(common wire) | KR/S/B/C/D-604/602P | ±5°c |
KC/D-604/602P | ±5°c |
J ( precisiont wire) | KR/S/B/C/D-604/602J | ±2°c |
KC/D-604/602J | --- |
Note:
1.Response time:less than 5 senconds.
2.Reproducibility:2ºC at 1650ºC
3.Probe Diameter :ID 18mm OD 30mm
4.Length: L=300~1800mm; (Description: the probe structure size can
be designed according to users' requirements.)