Home Companies Beijing Ding Ding Future Technology Co.Ltd

CE Rectifier Module Single Output With PFC LSP-150 HSP-200 UHP-200A HSP-300

Beijing Ding Ding Future Technology Co.Ltd

Contact Us

[China] country

Trade Verify

Address: No 803,Unit 3 ,DaDou Road, Huihao Building .Fangshan District,Beijing,China

Contact name:Lee

Inquir Now

Beijing Ding Ding Future Technology Co.Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CE Rectifier Module Single Output With PFC LSP-150 HSP-200 UHP-200A HSP-300

Country/Region china
City & Province beijing beijing
Categories Fuses
InquireNow

Product Details

 

MEAN WELL MOVING SIGN SERIES 150W- 400W Single Output with PFC LSP-150 HSP-200 UHP-200A HSP-300

 

MEAN WELL MOVING SIGN SERIES 150W- 400W Single Output with PFC LSP-150 HSP-200 UHP-200A HSP-300

 

 

Features:

Light weight and low profile

Suitable for high efficiency moving sign applications

Conformal coating (HSP, HDP, NEL, HSN series)

Semi-potted and design against rain splash (ERP Series)

 

 Parametets :

 

MODELLSP-160 -3.3LSP-160 -4.2LSP-160 -5LSP-160-12LSP-160-24LSP-160-36LSP-160-48

 

 

 

 

 

OUTPUT

DC VOLTAGE3.3V4.2V5V12V24V36V48V
RATED CURRENT32A32A32A13.5A6.75A4.5A3.4A
RATED POWER(convection)105.6W134.4W160W162W162W162W163.2W
RIPPLE & NOISE (max.) Note.2200mVp-p200mVp-p200mVp-p240mVp-p240mVp-p240mVp-p300mVp-p
VOLTAGE ADJ. RANGE3.2~3.5V4~4.5V4.7~5.3V11.4~12.6V22.8~25.2V34.2~37.8V45.6~50.4V
VOLTAGE TOLERANCE Note.3±2.0%±2.0%±2.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%±0.3%±0.3%±0.3%±0.3%
LOAD REGULATION±1.0%±1.0%±1.0%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)10ms/230VAC 10ms/115VAC

 

 

 

 

INPUT

VOLTAGE RANGE Note.4100 ~ 264VAC 141 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF≥0.94/230VAC PF≥0.98/115VAC at full load
EFFICIENCY (Typ.)87.5%88.5%89.5%92.5%93.5%93.5%93.5%
AC CURRENT (Typ.)2.2A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.)Cold start 45A/115VAC 85A/230VAC
LEAKAGE CURRENT<0.75mA / 240VAC

 

 

 

 

PROTECTION

SHORT CIRCUITHiccup protection,recovers automatically after fault condition is removed
OVERLOAD110~140% rated output power
Protection type : Constant current limiting,continous increase of load will be hiccup protection, recovers automatically after fault condition is removed

 

OVER VOLTAGE

3.8~ 4.6V4.62 ~ 5.46V5.75 ~ 6.75V13.2 ~ 15.6V26.4 ~ 31.2V39.6 ~46.8V52.8 ~ 62.4V
Protection type :Shut down O/P voltage,re-power on to recover
OVER TEMPERATUREShut down O/P voltage, re-power on to recover after temperature goes down

 

FUNCTION

CURRENT SHARINGPlease refer to the Function Manual
DC OK SIGNALContact rating(max.):15Vdc/10mA resistive load

 

 

ENVIRONMENT

WORKING TEMP.-30 ~ +70℃(Refer to “Derating Curve")
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT±0.03%/℃ (0 ~ 50℃)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY & EMC

(Note.6)

SAFETY STANDARDSUL62368,TUV BS EN/EN62368, CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved, Design refer to BS EN/EN60335-1
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC EMISSIONCompliance to BS EN/EN55032,GB9254,Class B, BS EN/EN55014,BS EN/EN61000-3-2,-3,EAC TP TC 020,BSMI CNS13438
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level ,EAC TP TC 020

 

OTHERS

MTBF2092.7K hrs min. Telcordia TR/SR-332(Bellcore) ;282.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION194*55*20mm (L*W*H)
PACKING0.356kg;30pcs/11.68kg/0.6CUFT

 

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details.

5. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft)

6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it

still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

 


 


 



 

 
 
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
 
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
 
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
 
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
 
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
 
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
 
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
 
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.
 

 
 
 
 
 
 
 

Hot Products

Enatel RM3048 3kW 48V DC Modular Rectifier modular RM3048HE Description: Designed for use in modern ...
Eltek DC rectifeirs Flatpack2 48/2000 SHE 48Vdc 2000W module (Part No.:241115.106) Flatpack2 48/2000 ...
Mean Well LRS Series 100W Single Switching Power Supply LRS-100-12 12V/8.5A/100W 1U thick Features : ...
Eltek Rectifiers Flatpack2 60/3000 SHE 60Vdc 3000W 97.85 high efficiency module (Part No.241119.706) ...
Mean Well Enclosed Switching Power Supply AC/DC UHP Series UHP-200(R) UHP-200A UHP-750 UHP-1500 UHP...
Eltek Micropack 12V/120W WOR 12V 120W rectifier module (Part No.: 241120.300) Micropack 12V/120W WOR ...