New Design HD 1U 19 Inch 1156 Cores MPO Fiber Optic Patch Panel for Data Center
Takfly's New Design High Density 1U 19 Inch 96 to 1156 Cores MPO MTP Fiber Optic Patch Panel is designed for large data center room: MDF application, IDF wiring area optical fiber backbone connection, the fiber distribution unit management, and other the high-density integrated optical fiber environment, etc. It is installed in 19 inch racks and cabinets.
This New Design High Density 1U 19 Inch 96 to 1156 Cores MPO MTP Fiber Optic Patch Panel could load 4 Pre-connected cassette module, and the maximum capacity can be managed is 1152 cores for MPO interface, or 96 cores for LC interface. Each independent pre-terminated module box is placed in the optical fiber distribution frame, to complete the full set patch panel
Takfly's New Design 1U 19 Inch MPO MTP Patch Panel aims to help Customers/Users to save more space in the cumputer room. Due to it's compact design and Aluminum material, it's quite economic and competitive, as it could help you save shipping cost.
New design MPO MTP Fiber Optic Patch Panel Specification:
U Size | 1U (44.2mm) | ||
Number LGX Cassette | 4 PCS | ||
Width | 482mm | ||
Depth | 200mm | ||
Net Weight | 1.4KG | ||
Packaged Weight | 2.2Kgs | ||
Material | Aluminum | ||
Material Coating | Oxidation of spray paint | ||
Color | Black | ||
Designed in Accordance With | TIA/EIA 568.C, ISO/IEC 11801, EN50173, IEC60304, | ||
IEC61754,EN297-1 | |||
Compliant to | RoHS | ||
Cores | 48Cores or 96Cores for LC, 1152Cores for MPO | ||
Insertion Loss (dB) | SM IL≤0.7dB(standard), MM IL≤0.6dB(standard) IL≤0.35dB(Low loss), | ||
Return Loss (dB) | SM RL ≥60dB(APC); SM RL ≥50dB(PC); MM RL ≥25dB(PC); |
Different Solutions for New design MPO MTP Fiber Optic Patch Panel:
Solution 1:
Model | LGX Cassette capacity | LGX | Total capacity | Connector type | Size | Application | |
A1 | R | 72F MPO*4 pcs | 4 | 1152F | MPO*16*4 | 1U | 1 pcs of A1 LGX Cassette connect with 4 pcs of C3 LGX Cassettes, full set of A1 connect with 4 full sets C3 |
T | 24 F MPO*12 pcs =288F | ||||||
C3 | R | 24F MPO*1 pc | 4 | 96F | MPO*1*4 | 1U | R:24F MPO*1*4, T:24F*4LC , connect with the terminal device by LC patch cord |
T | 24F LC | LC*24*4 |
Solution 2:
Model | LGX Cassette capacity | LGX | Total capacity | Connector type | Size | Application | |
A2 | R | 72F MPO*4 pcs | 4 | 1152F | MPO*10*4 | 1U | 1 pcs of A2 LGX Cassette connect with 3 pcs of C1 LGX Cassette , full set of A2 connect with 3 full sets C1 |
T | 48FMPO*6 pcs=288F | ||||||
C1 | R | 48F MPO*2 pcs | 4 | 384F | MPO*10*4 | 1U | 1 pcs of C1 LGX Cassette connect with 2 pcs D2 LGX Cassettes, full set C1 connect with 2 full sets D2 |
T | 12F MPO*8 pcs=96F | ||||||
D2 | R | 12F MPO*2 pcs | 4 | 96F | MPO*2*4 | 1U | R:12F MPO*2*4, T:24F*4 LC, connect with the terminal device by LC patch cord |
T | 24F LC | LC*24*4 |
Solution 3:
Model | LGX Cassette capacity | LGX | Total capacity | Connector type | Size | Application | |
B1 | R | 72F MPO*3 pcs | 4 | 864F | MPO*7*4 | 1U | R:72F MPO*3, T:16F MPO connect with the 400G transmission device by MPO patch cord, T:24F MPO can connect with C3 LGX Cassette |
T | 16F MPO*3 pcs 24F MPO*1 pcs=72F | ||||||
BG1 | R | 72F MPO*2 pcs | 4 | 576F | MPO*11*4 | 1U | 100G,400G dedicated cassette |
T | 16F MPO*9 pcs=144F | ||||||
C3 | R | 24F MPO*1pc | 4 | 96F | MPO*1*4 | 1U | R:24F MPO*1*4, T:24F*4LC, connect with the terminal equipment by LC patch cord |
New design MPO MTP Fiber Optic Patch Panel Application:
New design MPO MTP Fiber Optic Patch Panel Features:
New MPO MTP Fiber Optic Patch Panel Details:
How to order MPO/ MTP patch panel:
Why choose TAKFLY--Advantages as follows:
Professional manufacturer:
Quality Control:
Delivery:
Price: If your QTY is big, the price could be negotiated.
I have been working in this field more than 6 years, I believe, I could give you very good service and professional answers!
If you’re interested in our products or have any doubt, why not send me inquiry at once?