Protection Level 2.5KV Lightning Protection For Photovoltaic System SGS Approved

Country/Region china
City & Province dongguan
Categories Solar Chargers
InquireNow

Product Details

Protection level (at In) Up <2.5kv PV Surge Protector, 600V Network voltage

 

OBV5-C40-PV

 

Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules

Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)

Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.

Integrated d.c. fuse allows safe replacement of protection modules without arc formation.


Technical Parameters

 

Model: OBV5-C40-PV
Network voltage500Vdc600Vdc800Vdc900Vdc1000 Vdc 
Max. operating voltage Uc530Vdc630Vdc840Vdc950Vdc1060 Vdc 
Nominal discharge current ln20kA
Max. discharge current lmax40kA
Protection level (at In) Up1.8kV2.5kV2.8kV3.0kV3.2kV 
Disconnector
Thermal DisconnectorInternal
Mechanical characteristics
Connectionby screw terminals: 4-25 mm2
Disconnection indicator1 mechanical indicator by pole
Mountingsymmetrical rail 35 mm
Operating temperature-40/+85°C
Protection classIP20
Standards compliance
NF EN 61643-11 FranceParafoudre Basse Tension - Essais Classe II
IEC 61643-1 InternationalLow Voltage SPD - Test Class II
EN 61643-11 EuropeParafoudre Basse Tension - Essais Classe II

 

Feature&Benefits
 
-Easy installation or retrofit

-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact
-IP20 finger-safe designVisual indicator
-Small foot print
 
Application


●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
 

Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 

Surges in telecom andsignalling networks
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).

 
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.

 
What skills should lightning protectors have in the selection?
 
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

500V 800V 1000V photovoltaic surge protective device SPD HJH2-PV SPD NameDC Power Supply LightningDC ...
760V 27mm Surge Protection Device With 25kA Current Capacity OBV-I25: Uc(maximum continuous ...
Mature Technology 40kA Surge Protection Device Traditional Products OBV-II40-3 data: Uc(maximum ...
White Type 1 Surge Protection Device SPD Integral Structure Iimp 12.5kA Uc(maximum continuous ...
Up 1.8kV Imax 40kA SPD Surge Protection Device In PA66 And PBT Combined Material Uc(maximum ...
Imax 65kA Surge Protection Device With Four PE Location Preventing Module Vibration Uc(maximum ...