Un 24VDC CCTV Surge Protection Device , Rs485 Signal Control Surge Protection

 

Signal Line Protector OBVXJ

 

Surge protection devices designed for protection of data, communication, measuring and control lines against surge effects

OBVXJ is a protector with RS485 input and output connectors, able to hold up nominal discharge currents of 5kA for each line.
 


Technical Parameters

 

ReferenceOBVXJ-6OBVXJ-12OBVXJ-24OBVXJ-48
Nominal voltage : Un6Vdc12Vdc24Vdc48Vdc
Maximum continuous operating voltage: Uc8Vdc15Vdc30Vdc65Vdc
Nominal discharge current for line C2 10kV (1,2/50μs)/5kA (8/20μs): In (C2)5kA
Protection level at In (8/20μs):12V25V40V75V
Maximumworking current:300mA
Series resistance:15Ω
Response time:<10ns
Working temperature:-40℃+80℃
SPD location:Indoor
Type of connection:Series (two ports)
Input/Output connector:RS485/RS485
Certificated tests according to: IEC 61643-21, EN 61643-21

 

○ Protection for data lines and the digital or analogical equipments connected (computers, PLCs, discharge cells, etc.).

○ Wide variety of SPDs for different working voltages.
○ Both common and differential protection recommended for this type of lines.
○ Allows the connection of two pairs of lines with a very small size (0,75 DIN modules).
○ Pluggable modules for its easier substitution in case of failure without the need of disconnecting the wiring. When substituting the module the line suffers no interruptions.
○ Earthing implemented through a metallic sheet opposite to the fixing DIN rail.
○ In normal conditions stays inactive, without affecting the line working and without producing any leakage.
○ Low residual voltage in all the working voltages.
○ Very fast response.
○ Connection with screw pressure, which provides better lightning current withstanding capacity than usual telephone connectors.

 

Feature&Benefits
 
-Easy installation.
-Fail-safe /self-protected design.

-Very fast response.
-Hybrid GDT and Diode Technology.

-Connection with screw pressure.
-Allows the connection of lines with a very small size.


Application

 

●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~)Response Time(ns)
DGM1(2)-D5220/380

275/320
385/420

5101.2≤25
DGM1(2)-D101021.6
DGM1(2)-C2020401.8
DGM13-B303060.2.2
DGM3(4)-B4010802.4
DGM(4)-B60601002.8
DGM-N-PE220/25540/6060/801.2≤100

 

Key parameters of power surge protector:

 

●Maximum continuous withstand voltage Uc (rms):
means that the arrester can work continuously at this voltage value without affecting its parameters as the arrester. Uc is non-linearly proportional to the protection voltage Up.


● Maximum discharge current Imax:
Use 8/20μs wave surge arrester once, the maximum discharge current that can withstand. It can be selected according to the local thunderstorm intensity Ng (or the average annual thunderstorm day Td) and environmental factors.


●Residual voltage Ur and protection voltage Up
Residual voltage Ur: Refers to the residual voltage value under the rated discharge current In.
Protection voltage Up: The protection voltage Up is related to the Uc voltage and Ur. According to the characteristics of the zinc oxide varistor, when the Uc value of the selected varistor is high, its Up and Ur will increase accordingly, such as when the discharge current is 10kA (8/20μs):
Uc=275V Ur (10kA, 8/20μs) ≤1200V
Uc=385V Ur (10kA, 8/20μs) ≤1600V
Uc=440V Ur (10kA, 8/20μs) ≤1800V

 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Hot Products

500V 800V 1000V photovoltaic surge protective device SPD HJH2-PV SPD NameDC Power Supply LightningDC ...
760V 27mm Surge Protection Device With 25kA Current Capacity OBV-I25: Uc(maximum continuous ...
Mature Technology 40kA Surge Protection Device Traditional Products OBV-II40-3 data: Uc(maximum ...
White Type 1 Surge Protection Device SPD Integral Structure Iimp 12.5kA Uc(maximum continuous ...
Up 1.8kV Imax 40kA SPD Surge Protection Device In PA66 And PBT Combined Material Uc(maximum ...
Imax 65kA Surge Protection Device With Four PE Location Preventing Module Vibration Uc(maximum ...