Home Companies Starlight Industry Co.,Ltd.

1200KW Baudouin Biogas Generators Combined Heat And Power Generator

Starlight Industry Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Room 711, 7F, Unit 2, 1st Building, 666 Fengxi Avenue North Section, Wenjiang District, Chengdu

Contact name:Robin Liao

Inquir Now

Starlight Industry Co.,Ltd.

1200KW Baudouin Biogas Generators Combined Heat And Power Generator

Country/Region china
City & Province chengdu
Categories Gas Turbine Generators
InquireNow

Product Details

1200KW Baudouin Biogas CHP Biogas Electricity Generator

 

Technical Specification

 

Gas Generators

 

Weichai 16M33D1280NG gas engines and mecc alte ECO46 alternators are selected. In one canopy, one 1.2MW gas generator, one horizontal cooling system and one control system are integrated. The canopy is sand and catkin proof. The temperature zone control design enables the generator be normally operated at temperature range -30℃ to 50℃.

 

Total power plant capacity is 12MW and all generators are combined. Any of the generators can be backup set which enables urgent shift of any other generator. An isolate switch is installed for each of the generator which will isolate any gas generator when necessary.

Generator Model: EW-1200NGB-1/4A.

 

1.2MW Gas Generator Design

 

Canopy

 

The 30-feet long canopy is exclusively designed for the 1.2MW generator. The surface is coated by polyurethane which is shining and wear-resisting. In the canopy, there are control cabinet, generator cabin, air inlet/outlet filtering system. On the top of the canopy, there is horizontal cooling system. Gas supply is set at one end and power cable is connected from another end. This layout makes site gas pipe and cable arrangement easy and convenient.

 

Gas Engine

 

Baudouin 16M33D1289NG gas engine is selected. The gas engine is deeply developed in fuel control systems to improve its electric efficiency, reliability and fuel adaptivity for certain working conditions. The development also give consideration for dynamic responsiveness, fuel economy, reliability and safety.

 

Proven gas engine is controlled by imported gas close-loop lean-burn control system which includes latest Woodward control system, Hoerbiger intelligent ignition system, ABB high efficient turbocharger, single cylinder in-dependant compactive ignition, electrical speed regulating system, fuel close-loop control system, environment self-adaptation system and self diagnose and protection system. All these systems will ensure accurate and reliable control of gas engine and ensure its economic, dynamic and environmental performances. The systems are also optimized by our company to achieve high reliability and efficiency.

 

Cooling System

 

High-low temperature horizontal cooling system, high efficient, low power electrical fans, inter-cooler and jacket water cooling capacity close-cycle control are equipped to enable the generator being used in different ambient temperature.

 

Table 3-1:1.2MW Cooling System Parameters

 

 ITEMJacket RadiatorInter-cooler Radiator
Designed Ambient Temperature50℃45℃
Designed Cooling Power960kW130kW
1200kW Cooling Redundancy115%122%
1100kWCooling Redundancy128%139%
1000kWCooling Redundancy143%155%
Radiator Area≥670㎡≥505㎡
MaterialsCopper Pipes/Copper FinsCopper Pipes/Copper Fins
Applied Ambient Temperature-30℃~50℃-30℃~45℃
 

Alternator

 

Mecc Alte ECO46 brushless synchronous alternating-current generator with strengthen moving components is selected to improve the alternators resistance to load impact and interference and to ensure its long term reliable and stable operation.

 

Generator Set Control System

 

Generator control system is DEIF intelligent generator control system which realizes automatic start, speed up, switching on, parallel, load allocation, brake separation, cooling and halt. Remote control and monitoring system is also available.

 

Gas Generator Technical Parameters

                 Table 3-2 Technical Parameters for 1.2MW/400V Gas Generator

S.NItemParameters
1Generator Set1.2MW Gas Generator with Canopy
1.1Generator ModelEW-1200NGB-1/4A
1.2Rated Power1200kW
1.3Rated Current2165A
1.4Rated Voltage230/400V
1.5Rated Frequency50Hz
1.6Startup ModeDC24V Electrical Start
1.7Speed RegulationElectrical Regulation
1.8Fuel ControlLean-burn, Close-loop Control
1.9IgnitionElectrical Control Single Cylinder In-dependant High Energy Ignition
1.10Generator Set ControlOne-Button Startup/Stop
1.11Lubricant Consumption≤0.2g/kWh
1.12Electric Efficiency≥40.1%(80%~100% Load)
1.13Dimensions9000×3000×2900mm(Height after Installation 4500mm)
1.14Net Weight14900kg
2Engine
2.1BrandWeichai/Baudouin
2.2Model16M33D1280NG
2.3Displacement52.3L
2.4Air IntakeTurbocharge, Forced Inter-cooler, Four-valve Structure
2.5Rated rpm1500r/min
2.6CoolingWater-air Inter-cooler, Forced Water Cooling
2.7LubricationForced Splash Lubrication
2.8Engine Thermal Efficiency42%
3Alternator
3.1BrandMecc alte
3.2ModelECO46 1S4A
3.3Power Factor0.8(Lag)
3.4Generating Efficiency95.3%
3.5Alternator Capacity1500kVA
3.6Phase3-phase 4-wire
3.7Insulation GradeH
3.8Protection GradeIP23
4Generator Set Control System
4.1BrandDeif
4.2ModelAGC200
4.3FunctionsOne-button startup/stop, data display, Recording, Protection and Monitoring etc.
4.4DisplayerRpm/lubricant pressure/water temperature/ running hours/ current/ voltage/ Frequency/ active power/ reactive power/ load distribution etc
4.5Protection FunctionsAlarming and automatic control for high water temperature, low lubricant pressure, over speed, overcurrent, AC/DC voltage low/high, short circuit etc
5CanopyDust-proof canopy with positive pressure ventilation

1. The data is based on heat value on or above 35.88MJ/Nm3 natural gas which conform to ISO8528/1, ISO3046/1 and BS5514/1 standards.

2. Technical data acquired under standard conditions: barometric pressure: 100kPa,Ambient temperature: 25°C, relative humidity: 30%.

3. Under standard conditions the data conforms to DIN standard ISO 3046/1evaluation.Rated natural gas consumption tolerance is within ±5%.

4. Power factor is 0.8 and above.

5. Fume Nox contends ≤500ppm;

 

  • Gas Generator Functions
  • Startup Model

The gas generators are started by 24V DC battery. No other diesel generator or grid power supply needed.

  • Emergent Stop

There are manual emergent stop and automatic failure emergency stop in the cases of natural gas leakage, overcurrent etc.

  • Gas Generator Control

One-button control, air-fuel ratio auto adjustment, power factor auto control, automatic load increase and decrease can be realized on the generator.

Generator Control System: The control cabinet has one displayer. In the cabinet, there are controllers, relays, fuses, meters, adjusting buttons, indicators and emergent stop button to monitor and control the generator’s working process.

  • Generator Protection in case of Failure

The control system has protection functions and sound/light alarmings for over load, over current, short circuit, reverse power, underfrequency, overfrequency, undervoltage, overvoltage, over speed etc.

For slight failures like high temperature of cooling water, low pressure of lubricant, over load, fail startup, there will be light and sound alarming and auto or manual stop is allowed.

For severe failure like high temperature of engine, low lubricant pressure, over speed etc, it will stop automatically and alarming will be sent out.

  • Conditions for Generator Operation
    • Natural Gas Requirement
      • At rated power natural gas pressure at inlet flange shall be within 20kPa≥P≥50kPa.
      • At rated power natural gas inlet pipe ID shall be DN80 or above.
      • At normal operation gas heat value is 40.6MJ/Nm³, considering all other circumstances, natural gas supply rate shall be 2500Nm³/h or above (calculated at 10MW load).

                          Table 5-1: Required Compositions for Natural Gas

Gas TypeItemRequirement
Natural GasHeat Value MJ/Nm³≥34
CH4 Content by Volume %≥82
Overall Sulphur mg/Nm³≤200
H2S Content mg/Nm³≤15
Impurity Particle Size μm<5
Content of Impurity g/m³≤0.03
 

Note: There will be effect to the engine if natural gas is not as required.

Hot Products

625KVA Biogas CHP Heat & Power Cogeneration Description of 625KVA Biogas CHP Heat & Power Cogenerati...
350kW Natural Gas Heat & Power Cogeneration CHP Main Features of 350kW Natural Gas Heat & Power ...
200kW Biogas CHP Plant Cogeneration The project utilize 1 set Bio-gas CHP system and the system ...
50kW Biogas CHP Heat & Power Cogeneration #detail_decorate_root .magic-0{width:750px}#detail...
100-120kW Biogas Heat & Power Cogeneration CHP Description of 100-120kW Biogas Heat & Power ...
150kW Natural Gas Heat & Power Cogeneration CHP For the 150kW natural gas heat & power cogeneration ...