Home Companies Zhejiang Xinde Building Energy-saving Technology Co., Ltd

AVAILABLE FLOOR OPTIONS Facilities and lines hide in the stud

Zhejiang Xinde Building Energy-saving Technology Co., Ltd
Active Member

Contact Us

Address: Room 1212, Unit A, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District,Beijing,100025,P.R.C

Contact name:

Inquir Now

Zhejiang Xinde Building Energy-saving Technology Co., Ltd

AVAILABLE FLOOR OPTIONS Facilities and lines hide in the stud

City & Province beijing beijing
Categories Metal Building Materials
InquireNow

Product Details

After finishing the installation of floor, it goes to the upper structure. Even there is concrete, it doesn’t affect other structure and the installation of cladding material. Along with BFS specialized floor supporting system, it achieves excellent acoustic and insulation performance.
 

Dead Loads Used for Design   
Load Type Sub Total(kpa)Total Load
Sheet Roof0.48mm Sheet0.08 
OSB Cladding0.06 
Accessories0.060.20kpa
Tile RoofTerra Cotta Tiles0.56 
OSB Cladding0.06 
Accessories0.1 
Total 0.72kpa
Truss SelfWeight  0.06kN/m
Ceiling WeightPlasterboard0.1 
Accessories0.06 
Total 0.16kpa
Floor SelfWeightFloor Framing0.12 
Floor Sheeting0.15 
Accessories0.22 
Total 0.49kpa
Wall SelfWeightPlasterboard2x0.13 
Wall Weight0.08 
OSB Cladding2x0.06 
Accessories0.02 
Total 0.48kpa

 

Roof Snow Load 
LocationLoad
Intermediate Roof Snow Load0.00kpa
0.85kpa
Eave Snow Load0.00kpa
1.20kpa

 

Basic Wind Speeds and Factors 
ItemLoad
Permissible Wind Speed40 and 45m/s
Design Wind Pressure for 40m/s0.864kpa
Design Wind Pressure for 45m/s1.093kpa
External roof coefficients-0.90, +0.40
Internal roof coefficients+0.20, -0.30
External roof coefficients at eaves-1.8
Internal roof coefficients at eaves0.2
External wall coefficients0.7
Internal wall coefficients-0.3
External wall coefficients at corners-1.3
Internal wall coefficients at corners0.2

Hot Products

FORMULATION OF XINDE CONSTRUCTION SYSTEM STUD FLOOR U Track C Track
FORMULATION OF XINDE CONSTRUCTION SYSTEM U-CHORD ROOF TRUSS Web Top chord Bottom chord
FORMULATION OF XINDE CONSTRUCTION SYSTEM WALL FRAME Top plate Stud Bottom plate
FORMULATION OF XINDE CONSTRUCTION SYSTEM BAR FOUNDATION
Roof cladding can use terracotta tile, mason tile and metal tile. Floor system can choose wood floor...
After finishing the installation of floor, it goes to the upper structure. Even there is concrete, ...