ZHANGJIAGANG MEDPHARM MACHINERY LTD. |
Verified Suppliers
|
|
Floor standing Large Waste Autoclaves With Temperature Sensors For
CSSD
Key Feature
Functions
Controller Software
Sensors And Transducers
Chamber Vent Temperature
Load Temperature (Flexible Probe for liquid waste)
Chamber
Jacket
Water (Optional)
Compressed Air (Optional)
Steam (Optional, if fitted)
Model Chart
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-1.5 | 680*1180*1870 | 1600*2000*2210 | 2150 | 50 | 150 | 4.5 |
MD-2.0 | 1000*1200*1700 | 2000*2000*2040 | 2400 | 60 | 200 | 4.5 |
MD-3.0 | 1000*1500*2000 | 2000*2200*2340 | 2950 | 90 | 300 | 5 |
MD-4.0 | 1000*1500*2670 | 2000*2200*3010 | 3600 | 120 | 400 | 6 |
MD-5.0 | 1000*1500*3340 | 2000*2200*3680 | 4500 | 150 | 500 | 8 |
MD-6.0 | 1000*1500*4000 | 2000*2200*4340 | 5300 | 180 | 600 | 8 |
MD-8.0 | 1000*1500*5340 | 2000*2200*5680 | 6900 | 240 | 800 | 12 |
Materials
Chamber | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Jacket | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Door internal side | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
|
Features And Benefits
1. No Pre-Treatment Handling Risks
The System utilizes autoclavable carts that can eliminate employee
handling of untreated waste from point of generation to final
disposal.
2. Capital Cost
The Sterilizer is by far the least expensive medical waste
treatment system available.
3. Sterilizers Available For Any Size Facility
Units are capable of treating 100 to 1,125 lbs. or more per cycle.
4. Least Complicated To Operate
Some companies actually require the hospital to send engineers to
the factory for training. The Sterilizers require nothing more than
a brief in-service training period at the site following
installation.
5. Simple To Install
The Sterilizers are usually installed by hospital personnel, or
local equipment contractors.
6. Equipment Design Unchanged
There is no need to be concerned that the system will soon be out
of date, making it difficult to obtain parts and repairs.
7. Utility Consumption
Most Medpharm Sterilizers use existing low cost readily available
hospital steam supply.
8. Steam Sterilization Vs Disinfection
Because of the National and World focus on the spread of infectious
disease, the eradication of all microbial life in the waste stream
is imperative. The Sterilization process is the best assurance the
hospital can have for proper spore kill.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf