LZCK series split core current transformer is suitable forcurrent
measurement and microcomputer protection of electrical equipment in
10KV and 35KV AC power system.It is widely used in compact fully
insulated ring network switchgears such as ABB-Safe Ring/Safe
Plus...and cable distribution boxes.The transformer can be directly
installed at the inlet andoutlet cables.The slice is imported
silicon material. Thesemicircular ring core and secondary windings
arevacuum poured by insulated resin.
P1, P2 is primary polarity terminal, S1, S2 is secondary polarity
terminal.
P2, S2 is homonymous terminals (subtractive polarity).
PARAMETERS
Technical parameters |
---|
Standards | IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 |
Rated primary current | 30-600A |
Rated load | ≤10VA |
Rated frequency | 50Hz or 60Hz |
Rated secondary current | 5A or 1A |
Rated short-time thermal current | 40kA, 1S |
Rated continuous thermal current | 120%I1n |
Secondary winding power-frequency voltage | 3kV, 1min |
Instrument security factor | FS≤10 |
Mechanical parameters |
---|
Dimensions (W×D×H) (mm) | φ50xφ110x52 |
Weight (kg) | 1.6 |
Operating conditions |
---|
Operating temperature | -35°C to +55°C |
Daily average temp | <+40°C |
Altitude | <3500 meters |
Condition | No existence of severely begrimed, erosive and radioactive gas in
the air. Permission of long-term operation under rated current. |
TECHNICAL DATA
Type | LZCK322-10 | LZCK322-10 |
---|
Purpose | Measuring current transformer | Protection current transformer |
---|
Ratio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) |
---|
I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 |
30/1 | | 1 | 1.5 | | | |
50/1 | | 1 | 2 | | | 1.25 |
75/1 | | 1.5 | 2.5 | | 1 | 2 |
100/1 | 2 | 2.5 | 3 | | 1.5 | 2.5 |
200/1 | 2.5 | | | 1.25 | 2.5 | |
300/1 | 3.75 | | | 1.25 | 2.5 | |
400/1 | 7.5 | | | 1.25 | 2.5 | |
500/1 | 10 | | | 1.25 | 3 | |
600/1 | 10 | | | 1.5 | 3 | |
50/5 | | | 2.5 | | | |
75/5 | | | 2.5 | | | |
100/5 | 2.5 | | | | | |
200/5 | 3.75 | | | | | |
300/5 | 5 | | | | | |
400/5 | 7.5 | | | | 2.5 | |
500/5 | 7.5 | | | | 2.5 | |
600/5 | 10 | | | | 3.75 | |
SELECTION GUIDE
Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
---|
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |
http://gfuve.com/split-core-current-transformer/33kv-high-voltage-split-core-current-transformer.html