Six Phase Universal protection Relay Test set

Overview

1. Six-channel current output

2. Six-channel voltage output

3. Six-channel share of DC current

4. Six-channel DC voltage output

5. Eight pairs of binary input

6. Four pairs of binary output.

Features

1.Integration in the host crystal 8.4 inches true color, light weight and easy to carry.

2. Built-in high-speed high-performance industrial computer, embedded operating system, running a stable and reliable; also be connected PC testing.

3. Panel embedded user-friendly buttons can also be an external keyboard, mouse.

4. High-precision DAC to 12 Road, simultaneous output to ensure that waveform fitting of high precision, good linearity.

5. Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can be connected electromagnetic compatibility tests.

6. Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and test parameters of the surveillance.

7. Designed to the latest thermal structure, and to ensure the best ventilation. Automatically determine the over-current, over voltage, overload, short circuit, the temperature is too high, data anomalies and misuse warning prompt.

8. Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision, good reliability; six-phase AC output voltage and six-phase AC current.

9. 12 analog ports and the other optional auxiliary DC source output (220V/110V).

10.Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use).

Functions

1.Host real-time operating system, fast response, when faced with an emergency situation, to better protection of instruments and equipment under test. Safe and reliable, not easy to be a computer virus violated.

2. Newly designed software interface style, Host machine operation is fully consistent with the background and easy.

3. Extensive testing capabilities: the state sequence determined in the trial, IT features analog oscillation, the entire group of tests, differential protection, harmonic superposition, low cycle load shedding, same equipment, measuring instruments, GPS synchronized debugging, fault playback, and custom test (special tests), etc., to satisfy various types of user testing microprocessor-based protection relay needs.

4. Easily complete the ABB, Siemens, AREVA and other foreign manufacturers of protective device test.

5. The test report can be easily derived from the USB port to print.

Specifications

AC current output

Phase current output (effective value)

6×0-30A or 3×0-60A

Maximum output power

520VA/phase

Maximum parallel current output (effective value)

0-180A

Long-term allowable working value of phase current (effective value)

>10A

Allowable working time of maximum current

>11s

Accuracy

<±0.2%

AC voltage output

Phase voltage output (effective value)

6×0-130V

Line voltage output (effective value)

0-260V

Maximum output power

70VA/phase

Accuracy

<±0.2%

DC voltage output

Output range

0-300V or 6×0-±130V

Maximum output power

130VA

Accuracy

<±0.2%

DC current output

Output range

-10-10A or 6×0-±10A

Maximum output power

150VA

Accuracy

<±0.2%

Binary input

Idle contact

1-20mA, 24V (DC)

Electric potential contact

0-250V (DC)

Binary output

Idle contact

250V/0.5A (DC)

Rated output

Frequency error

<±0.01Hz

Phase error

<±0. 2°

Waveform distortion

<±0.3% (fundamental wave)

Time error

<40µs

Output frequency

0-1050Hz

Superposed harmonic wave

0-21times

Power voltage

Allowable range

AC220V±10%, 50Hz±10%

Ambient temperature

Use range

0-45℃

Storage range

-25-70℃

Time measurement

Test range

0.1ms-999999.999s

Exterior appearance of cabinet

Imported electromagnetic compatible cabinet, which is made of high-grade all aluminum alloy extruded section and has fine appearance, is selected.

Dimension of cabinet(L x W x H): 360mm ×195mm ×365mm

Weight of cabinet

Weight of host machine

16.6kg

Load-bearing output

Selectable between light load or heavy load output

(When any phase current output surpasses 15A, it is suggested to press key F3 before test of each functional module so as to switch to heavy load output mode)

Product photos


Company Introduction

Certifications

Trading Process

Packaging & Shipping

Services

Hot Products

GF2018 wireless 1000A High voltage clamp ammeter recorder with Insulating Rod GF2018 is the newest ...
GF2011 1000A CLASS 1 PORTABLE PRIMARY CURRENT WIRELESS HIGH VOLTAGE AMMETER IN 10KV POWER LINE ...
GF2011 1000A 10KV PORTABLE PRIMARY CURRENT WIRELESS HIGH VOLTAGE CLAMP METER GF2011 1000a Portable ...
GF2018 USA MV High Voltage Wireless Primary Current clamp recorder 1. Collect and analyze load ...
GF2015 Primary Current medium voltage clamp meter with wireless 1. Collect and analyze load profiles ...
GF2011 GFUVE Global wholesale WIRELESS HIGH VOLTAGE HV current sensor GF2011 High Voltage Ammeter ...