Product Details

 

 

 

 

Customised Sodium Hypochlorite Wastewater Treatment NaClO Generator

 

 

Principle:

 

    CNJS - S series NaClO generator is a new type of NaClO solution for field production equipment , suitable for all kinds of needs NaClO disinfected venues. Its working principle is:

  the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:

                                                                            Electrode reaction:

anode:2Cl--2e→Cl2

cathode:2H++2e→H2

Solution:2NaOH+Cl2→NaCl+NaClO+H2O


Technical parameters:

Type

Power(V/Hz)

concentration of liquid(mg/l)

available chlorine (Kg/h)

Flow (m3/h)

Salt consumption (kg/d)

Water consumption (m3/d)

Power consumption   (kw)

Size(m)      (l×w×h)

CNJS-S5000

380V/50Hz

7-9

5

0.5

336

12

20

1200*860*

1950

 

 

 

Work flow chart :

 

Automatic sodium hypochlorite generator system fully automatic production, contains the system

 

A, Automatic dissolving salt tank :Including salt tank , liquid level control , dissolving salt pump , electric valves , piping and other components which could automatic transmission salt , dissolving salt , saturated brine

B, Saturated brine filter :Including stainless steel two precision filter ,primary filtering accuracy 50um, secondary filtration precision 5um, use PP filter , the filter can be easily replaced, ensure clean brine ;

C, Dilute brine tank :The saturated brine and production water has been diluted with 2.5 % weak brine water , for the power solutions

D, Sodium hypochlorite generator host machine :Including electrolytic cell , electrolysis power , intelligent control center PLC , the control element, man-machine interface , PC communication module, the operator panel, the host stand, electric valves, electrical power distribution system

E, Sodium hypochlorite solution storage tank :including hydrogen storage tank , exhaust equipment

F, Automatic dosing and on-line monitoring system: including the inverter , corrosion metering dosing pump , online residual chlorine monitor , and the closed-loop control of chlorine

G, Online instrument series : Production water pressure monitoring , dilute brine online salinity monitoring , temperature controller , flammable gas monitoring sensor , these monitoring instruments are all included alarm signal output

 

 

Advantage of on-site sodium hypochlorite generator

 

Compared with other brand

 

CNJS Technology

other brand

Advantages of CNJS

Appearance

CNJY Y1000 on-site sodium hypochlorite generation split type multifunctional

Other equipment framework will rust after three months and  three years later, will affect the service life of equipment. CNJY equipment framework use alumina material, and does not rust

 

Space

Host machine size:1200*860*1950

Host machine :2000*1000*2200              Control cabinet:850*700*1800          rectifier:500*1000*1100                 Host machine , Control cabinet , rectifier can not put in one rom together , need anther device room

saving space Easy to install and operate

Raw material

refined salt or Industrial salt

refined salt

A wide scope of utility, economy and low operating cost

Inlet water requirements

Depend on actual situation need a water softener or not

 indispensable a water softener

Can reduce unnecessary link,  increase equipment safety.

Brine concentration

Salt brine mixing device, fully dissolved, ensure the stability of brine concentration.

No mixing device, brine concentration is not stable.

The stable liquid concentration,extend equipment service life.

Dilute brine ratio

 water injector ratio

 normal valve

High accuracy, more safety

Generator fixed way

All moulds are fixed, equipment installation is more stable

With simple metal ring, need to reinforce the equipment

CNJY Y1000 on-site sodium hypochlorite generation split type multifunctional

Structure of electrode slices

Bipolar type, in series, big gap, large flux

Bipolar type,small gap, small flux

Big flux , easy to control temperature equipment,electrode service long life

Thickness of electrodes

2mm

1.5mm

Long life of electrode, resistance to deformation, not short-circuited.

Dosing accuracy

Multilayer additive form, adding the high precision

Quantitative dosing, water data is not stable

Water stable,long service life

Intelligent control

Truly intelligent, fully integrated modular structure

Distributed assembly, intelligent poor

High performance and stability

Power system

Using marine-grade high-frequency voltage constant current power supply, low heat, stable and integrated and equipment

SCR ballast, large energy consumption, no security, occupy  space, poor stability

Low power consumption, covers an area of small, low malfunction

Pickling process

Small devices not pickling, large equipment protection pickling mobile devices

Small equipment to pickling, large equipment pickling less protection

Free of acid pickling, more stable, more safe.

The man-machine interface

Small devices with Siemens touch screen, large equipment with industrial man-machine interface

Small equipment without man- machine interface, large equipment with normal interface

Convenient and easy to use

The PLC program

All size equipment configuration of the PLC, unattended and intelligent control.

Small equipment without PLC, often appear effluent water  not stable

Suitable for anyone, no need  professionals.

Security

Fully enclosed structure, high stability and high safety of the equipment

All the equipment and instruments outside naked, fragile and aging

Easy installation, long service life

Service life

More than 8 years

Less than 5 years

 

Warranty time

15 years

10 years

 

 

 

 

 

 

 

 

 

 

Details :

 

 

 

CNJS Technology : Full framework of alumina , corrosion resistance,

Compressive strength , impact resistance

Never rust , design life for more than 50 years

 

 

 

 

Other brand :

 Full channel structure , no corrosion , easy to deformation and rust , after half year the framework like above figure , the useful life is  only three years.

 

 

Hot Products

Disinfection Brine Electrolysis Sodium Hypochlorite Production Plant 400G/H Technical parameters : ...
1kg Sodium Hypochlorite Generator Machine for Water Plant Disinfection Product introduction: ...
1,The anode and cathode are both made of TA1 material. The surface of the anode is coated with 20 ...
Large Water Treatment Plant Sodium Hypochlorite Generator Custom Made Product introduction: ...
1,Advantages Of Sodium Hypochlorite Generator----Safety,Economy,Practical 2,Overview Of Hypochlorite ...
1,Advantages Of Sodium Hypochlorite Generator----Safety,Economy,Practical 2,Overview Of Hypochlorite ...