Home Companies WUHAN RADARKING ELECTRONICS CORP.

CPU Card Smart Electric Meters Single Phase Multi Function Smart Meter for AMR System

WUHAN RADARKING ELECTRONICS CORP.

Contact Us

[China] country

Trade Verify

Address: No.270, Huangjinkou 3rd Village, Hanyang District, Wuhan City, Hubei Province, China

Contact name:Ada Yang

Inquir Now

WUHAN RADARKING ELECTRONICS CORP.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CPU Card Smart Electric Meters Single Phase Multi Function Smart Meter for AMR System

Country/Region china
City & Province wuhan hubei
Categories Other Electric Power Tools
InquireNow

Product Details

CPU Card Smart Electric Meters Single Phase Multi Function Smart Meter for AMR System

 

 

The DDZY150 type electronic single phase multi-rate watt-hour meter adopts advanced energy metering chip, combined with mature multi-rate technology by using digital sampling processing and SMT technology. We develop this international standard meter according to residents’ actual power consumption. It offers functions as time measurement, automatically archived data set, hand-held terminal or PC programming and meter reading, also the LCD display etc..

 

The meter has two sets of fee charged. It can be transferred automatically as arranged; each set supports no less than four rates. It offers positive and reverse active energy metering, time measurement, separately memorizing electricity energy for the total, sharp, peak, level and valley period.

 

Features: 

 

1. Metering

  • Measuring for positive and reverse active power, storage the data, and according to which setting active group
  • Multi tariff. For active power, it can accumulate and storage total, top, peak, flat, valley power according to certain period.
  • It can storage total power and power for each tariff for last 12 months. The boundary is 24:00pm of end of month, or on the hour from 1st to 28th for every month.

2. Remote Fee Control

It finished parameter setting and remote purchasing through RS485, carrier and other virtual medium..

 

2.1 Remote Fee Control Electricity Meter

The calculative process for electricity is finished in remote system, there is no relative information such as electricity fee have been stored or displayed in meter. Meter has to pass strict password authentication and safe certification since getting remote commands such as switch out, switch on, ESAM data reading.

 

2.2 Encryption required for safe certification

      To make sure the reliable and safe data transportation, the commands from meter through solid or virtual medium have to pass strict password authentication or safe certification such as ESAM module.

 

3. Measuring and Monitoring

 

It can measure and monitor operating parameter such as voltage, current (including zero line current), power, power factor and etc. The error would not exceed ±1%

 

4. Event Log

  • Permanent record the time when reset happened, and also the data on that time.
  • Recording total times for programming, the time for last 10 programming and also operation code and data identification for programming.
  • Recording total times for timing (not including time broadcasting), the time for last 10 timing and also operation code.
  • Recording total times for power down, the time for last 10 power down and power on.
  • Recording the last 10 times for switch out and on by remote control, and also the time for switch out/on, power and etc.
  • Recording the total times for opening meter cover, the time for last 10 opening happened and finished.

 

5. Display

  • The following information would be displayed in meter:
  • The unit for power is kWh, and 8 digital display, including 2 decimals
  • LCD backlight wake up methods including switch wake up, infrared wake up(any infrared can work) and etc. In normal use, the life time for LCD won’t be less than 10 years
  • When power off, the backlight can be woke up by switch; If no operation after waking up, LCD would close automatically after a cycle; If operation exist, LCD would close automatically in 30 seconds after operation.
  • Indicator: --Pulse Red, it is off in normal condition, and would be flash when measuring active power

--Alarm Red, it is off in normal condition, and would be on when alarming

--Trip Yellow, it is off in normal condition, and would be on when load switch disconnect.

 

6. Alarm

When the following faults or alarm appear, LCD would stop on the certain code and backlight keep on.

Error Code

Err-01 Control Loop Error

Err-02 ESAM Error

Err-04 Low Voltage for Clock Battery

Err-08 Clock Error

Err-10 Error for Certification

Err-16 Error for Key Correction

 

7. Freezing

  • Time Freezing: Freezing meter data according to the promissory time and interval; It can keep at least 12 times for each frozen fraction.
  • Instantaneous Freezing: Under improper condition, freezing current date time, all power and important measurement data; It keeps the data for last 3 times.
  • Appoint Freezing: In any case of older/new tariff, step tariff changeover and other situation which is necessary, the meter would freeze power and other important data on the changeover time, It keeps the data for last 2 times
  • Day Freezing: Store power on 0.00am for each day, total for 2 month
  • On Hour Freezing: Store active power for hour or half an hour, total for 96 data

 

8. Timing

Build in clock circuit with temperature compensation function, the calendar, timing, leap year can be changed over automatically. The output frequency for inner clock terminal is 1Hz. Between -25℃ to +60℃, clock accuracy is no more than ±1 s/d; Under reference temperature 23℃, clock accuracy is no more than ±0.5 s/d.

 

The accepted time broadcasting is no more than 5 min. No need to match with programming switch and communication password when time broadcasting. It can be set according to the inquire, and it avoid from handling in 5 min at the time when freezing or data storing.

 

9. Pulse Output

Meter has function for LED pulse and electrical pulse output which comes direct ratio with measuring energy. Optical test output device should comply gb/t17215.211-2006, electricity test output device should comply GB/T15284-2002. It has signal output terminal for clock, and the output frequency is 1Hz

 

10. Load Switch

External load switch, there is a group of switch signal for meter output. Volume of switch point is AC 220V/2A. Under normal condition, switch signal for output should keep switch on of load switch, allow for power on; When reach certain condition, switch signal for output should drive operation for external load switch, power off.

 

 

 

Datasheet

Nominal voltage Un220/230/240 V
Limited voltage70%~120%Un
Nominal frequency fn50-60Hz+5%
Basic current(Ib)5-10A
Maximum current(Imax)60-100A
Starting current(Ist)20mA
Active energy constant1000imp/kWh
Accuracy as Active energy to IEC62053‐21Class1.0
Power consumption in Voltage circuit<2W <8VA
Power consumption in current circuit<1VA
Operating temperature25℃ to+70℃
Storage temperature40℃ to+85℃
Insulation level4kV rms for 1min
Impulse voltage withstand8kV, 1.2/50 μs
Air discharge16kV
Immunity to HF fields 
80MHz to 2GHz with load10V/m
100kHz to 1GHz without load30V/m
Fast transient burst test4kV
Meter shell Protection RateIP54(IEC60529)
Insulation System ClassificationProtective Class II

 

 

Safety precautions:
* Use only isolated tools.
* Do not connect the meter to a 3 phase - 415V AC - network.
* Place the meter only in dry surroundings.
* Make sure the used wires are suitable for the max current the meter can measure.
* Make sure the AC wires are installed correctly before activating the current/voltage.
* Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
* Make sure the protection cover is placed after installation and has been sealed.
* Installation, maintenance and repair should only be done by a certified electrician.

Hot Products

Reliable 220V Digital Single Phase Electric Meter With Waterproof Design Descrition: Single phase ...
Single Phase Keypad Digital Electric Prepayment Electricity Meter with STS Description: Keypad ...
LED Display Digital Single Phase Electric Energy Meter for different country Specification: Name ...
220V/230V Single Phase Active Energy Meter Prevent From Electricity Stolen Description: Single phase ...
Anti Aging Properties Single Phase Electric Meter , Infrared Kwh Meter 1 Phase Description: Single ...
220V 3200imp/Kwh Active Energy Meter Single Phase Electronic Meter With LCD Display Description: ...