Multi Function Smart Three Phase Four WIres KWH Meter Active Reactive Measure

 

Summary:

DTZY150-Z three phase four wires remote fee control smart electric meter is a intelligent electric metering product which made of large scale integrated circuit, with Digital sampling processing technology and SMT craft.

It is compatible with IEC 62053-21 <Part 21L Static meters for active energy classes 1 and 2>,and meet with DL/T645–2007 <Multi function static meter communication protocol> requirements.

 

 

Main Parameter: 

Item Specification
Reference Voltage3×220V/380V
Working Voltage Range0.8Un~1.15Un
Maximum Working Voltage0.7Un~1.2Un
Reference Current1.5(6)A 5(40)A 5(60)A 15(60)A 20(100)A
AccuracyActive CL 1.0Reactive CL 2.0
Working Temperature-25℃~+60℃
Maximum Working Temperature-40℃~+70℃

 

Features: 
1. Metering
1.1 Positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phase which can be measured. It can set tagged words of active/reactive combination, aim at positive/reverse active power and reactive power in 4 quadrants, to restructure active combination, reactive combination 1 and reactive combination 2.
1.2 All power can be time-share measured by total and max 4 tariffs. (No time-share measurement for power in A, B, C phases)
1.3 It can storage power data for 12 settlement period.
1.4 For positive/reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 quadrants and active/reactive power in A, B, C phases, the valid range is 0~999999.99, and unit is kWh or kvarh.
1.5 For active combination, reactive combination 1 and reactive combination 2 power, the valid range is –799999.99~799999.99, and unit is kWh or kvarh.

 

2. Remote ON/OFF Control:Remote ON/OFF control through background software, senior password authorization needed.

 

3. Tariff
3.1 It can set solution for 2 time zones, 2 daily periods and switching time (yy/mm/dd/hh/mm) of both two.1st time zone and daily period solution is default selection, when reach switching time of time zone, it changes to 2nd solution of time zone, and when reach switching time of daily period, it changes to 2nd solution of daily period. Then set switching time again for 2 solutions,when reach switching time of time zone, it changes to 1st solution of time zone, and when reach switching time of daily period, it changes to 1st solution of daily period. Switching time would be clear since changes of time zone solution and daily period solution.
​3.2 Max 4 tariffs. Each time zone solution can set 14 time zones as max, with starting time and meter number of daily period which is used. Each daily period solution can set 8 daily periods as max, 14 periods per day, with starting time and tariff which is used. Minimum interval of periods is 15 mins., and period interval is larger than actual demand cycle valve, can be set over 00:00. Public holiday can be set, including date and daily period meter number of each public holiday.
3.3 Weekend holiday can be set, which controlled by tagged word, daily period meter number can also be set for each weekend holiday.
3.4 If the same for public holiday and weekend holiday, daily period meter number of public holiday will be used.
3.5 Automatic changeover of century calendar, time, leap year.
3.6 If tariff number in the period of daily period is larger than tariffs, or the tariffs is 0, the power in the period reckon in tariff 1.

 

4. Demand Measurement

 

5. Settlement Function

 

6. Meter Clear

 

7. Demand Clear

 

8. Event Clear

 

9. Power Freezing

 

10. Security Management & User Authorization

 

11. Warning Function

 

12. Power Off Meter Reading Function

 

13. Clock, Time Function

 

14. Signal Output Function

 

15. Basic Communiction Function

 

16. LCD Display Function

 

Notes:

No device inside can be adjust by user.

When installing and using, there should be tight enough for each connection line, to avoid from any bad connection which would cause heating to damage the meter. Make sure of the right connection of input and output. Please install the meter on local where is dry and ventilated. Don’t put in the place under direct highlight, especial for infrared window. When using infrared communication, it should take more attention to avoid from any disturb from highlight to infrared interface, and please adjust the distance and angel of infrared, to make sure of reliable communication.

 

 

 

 

 

 

 

Hot Products

Reliable 220V Digital Single Phase Electric Meter With Waterproof Design Descrition: Single phase ...
Single Phase Keypad Digital Electric Prepayment Electricity Meter with STS Description: Keypad ...
LED Display Digital Single Phase Electric Energy Meter for different country Specification: Name ...
220V/230V Single Phase Active Energy Meter Prevent From Electricity Stolen Description: Single phase ...
Anti Aging Properties Single Phase Electric Meter , Infrared Kwh Meter 1 Phase Description: Single ...
220V 3200imp/Kwh Active Energy Meter Single Phase Electronic Meter With LCD Display Description: ...