Home Companies SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

600uA Automatic Digital Multimeter

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
Active Member

Contact Us

[China] country

Address: 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China

Contact name:Emily Tan

Inquir Now

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

600uA Automatic Digital Multimeter

Country/Region china
City & Province shenzhen guangdong
Categories Electric Wrenches
InquireNow

Product Details

 

600V AC (RMS) or 600V DC Temperature And Humidity Meter

 

 
 Buzzer

 

When the key is pressed or the function switch is on, the buzzer will sound "Beep" (about 0.25 seconds). If the measured voltage or current is greater than the set alarm value, for example, the AC voltage is greater than 600V, The voltage is greater than 600V, AC and DC current greater than 10A, the buzzer will continue to pronounce, as over-range warning; automatically shut down about 1 minute before the buzzer will be issued five consecutive warning, before the shutdown buzzer will send a long warning ; When the automatic shutdown function is canceled, every 15 minutes will be issued 5 consecutive warning.

 

 

Automatic shutdown

 

1) If there is no operation for any 15 minutes after power on, the instrument will go to sleep automatically to save power. 1 minute before the shutdown, the buzzer has 5 prompts, shut down before a long sound into the dormant state. (Note: automatic shutdown is still 3 ~ 5uA of the working current, a long time do not use the best to go to OFF or unplug the battery)

2) automatically shut down, press the FUNC key, the instrument to resume working status. Or turn the knob switch to OFF, and then rotate to the desired range.

3) If the "FUNC" key is pressed while the unit is turned on, the auto power off function is canceled. 13

 
 
Technical indicators
 
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it is on the AC function, the instrument may display 1 to 50 if the measured signal is not input (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement. Therefore, the AC voltage and current range is specified between 2% and 100% of full scale.
 
 
 
3.2.2 DC voltage

RangeResolutionAccuracy
6V0.001V±(0.5% of reading + 5 words)
60V0.01V
600V0.1V±(0.8% of reading + 5 words)

- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
3.2.3 AC voltage
 

RangeResolutionAccuracy
6V0.001V±(0.8% of reading + 3words)
60V0.01V
600V0.1V±(1.0% of reading + 10words)

- Input impedance: 10MΩ

- Maximum input voltage: 600V AC (RMS) or 600V DC

- Frequency range: 40 ~ 1000Hz True RMS

Note:
In the small voltage range, the pen is not connected to the circuit under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high sensitivity, does not affect the actual measurement results.
 
 
 
3.2.4 Alternating current
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.5% of reading +10words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.5% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
 
3.2.5 DC
 

RangeResolutionAccuracy
600.0uA0.1uA±(1.0% of reading +5words)
6000uA1uA
60.00mA0.01mA
600.0mA0.1mA
6A0.001A±(2.0% of reading +10words)
10A0.01A

- Overload protection: mA range fuse (self-recovery fuse 200mA / 250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous measurement time is not longer than 15 seconds, after the measurement to stop the current measurement for more than 1 minute.
 


 
3.2.6 Frequency
 

RangeResolutionAccuracy
9.999Hz0.001Hz±(1.0% of reading +3words)
99.99Hz0.01Hz
999.9Hz0.1Hz
9.999kHz0.001kHz
99.99KHZ0.01kHZ
999.9KHZ0.1KHZ
9.999MHZ0.001MHZ

- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency increases, the input voltage should also increase)
 
 
3.2.7 Duty cycle
 

RangeResolutionAccuracy
0.1 – 99.9%0.1%± 3.0%

- Frequency response: 10 ~ 10MHz

- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)

- Maximum input voltage: 250V AC (rms)
 
 

Resistance
 

RangeResolutionAccuracy
600W0.1W±(0.8% of reading +3words)
6kW0.001kW
60kW0.01kW
600kW0.1kW
6MW0.001MW±(1.2% of reading +3words)
60MW0.01MW

- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
 
 

Transistor test

 

RangeDescriptionTest Conditions
hFEThe display reads the approximate value of hFE(0~1000)Base current of about 10uA; Vce about 2.8V

 

 

Capacitance

 

RangeResolutionAccuracy
9.999nF0.001nF±(4.0% of reading +3words)
99.99nF0.01nF
999.9nF0.1nF
9.999mF0.001mF
99.99mF0.01mF
999.9mF0.1mF
9.999mF0.001mF±(5.0% of reading +3words)
99.99mF0.01mFNot calibrated

- Overload protection: 250V DC or AC (rms)

 

 

Temperature test

 

RangeAccuracyResolution
-20℃-300℃±(1.0%+4d)1℃
301℃-1000℃±(1.9%+5d)1℃
-4℉-600℉±(1.2%+6d)1℉
601℉-1832℉±(1.9%+6d)1℉

- Overload protection: 250V DC or AC (rms)

 

 

Hot Products

Anti Shock Digital Smart Multimeter Auto Ranging 9.999nF 99.99nF Description: 1.1.1 When using the ...
Manual Range 1000V Digital Smart Multimeter Sine Wave Signal RMS Measurement Manual Range 60Hz ...
LCD display True Rms Digital Smart Multimeter Anti High Voltage Circuit Description: True RMS The ...
LCD Digital multimeter DC AC Voltage Diode Freguence multimeter Volt Tester Test Current Follow the ...
Lightweight 600V DC Auto Ranging Digital Multimeter 9999 Counts Display Technical indicators Ambient ...
1000V DC 0.01V 600V AC 19999 Counts Electrical Digital Multimeter True RMS Voltage Meter Technical ...