Home Companies SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

Environmental Sound Level Meter with LCD Display 31.5Hz 8KHz

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
Active Member

Contact Us

[China] country

Address: 502, No. 31, Yangmei Road, Bantian Street, Shenzhen, Guangdong, China

Contact name:Emily Tan

Inquir Now

SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED

Environmental Sound Level Meter with LCD Display 31.5Hz 8KHz

Country/Region china
City & Province shenzhen guangdong
Categories Other Computer Accessories
InquireNow

Product Details

 

wholesale Electrical Socket Tester Voltage Test Socket detector EU Plug Ground Zero Line Plug

 

 

1. Safety


Read the following safety information carefully before attempting to operate or service the meter.
Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
▲ Environment conditions:
1. RH≤90RH%(Non-condensation)
2. Operating temperature:-20~60℃/-4~140℉
▲ Maintenance
1. Repairs or servicing not covered in this manual should only be performed by qualified personnel.
2. Wipe the unit with a dry soft cloth. Do not use abrasives or solvents on this instrument.
▲ Safety Symbol:Comply with EMC

 

 

2. Application


This unit adopts condenser microphone as the sensor, high configuration MCU calculation, high accuracy, fast response. This Sound Level Meter is designed to meet the measurement requirements of safety Engineers, Health, Industrial safety offices and sound quality control in various environments like factory, school, construction, etc.

 

 

3. Features

 

  • High accuracy, fast response
  • Color LCD display with backlight
  • Temperature measurement
  • MAX,MIN
  • Data HOLD
  • Wide frequency range
  • Fast/slow time weighting
  • Over range indication
  • Enable/Disable auto power off

 

4. Basic Operation


4.1. Open battery cover and install 3*1.5v AAA batteries in the battery compartment.
4.2. Power on;press“ ”to turn on the meter,the meter conducts self-inspection, after LCD displays, it measures temperature and sound level automatically.
4.3. After testing,Press“ ”to turn off the meter
Note: Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage

 

 

5. Specification

 

Applied StandardIEC61672-1 CLASS2
Measuring level range35dB~135dB
Dynamic range50dB
Frequency range31.5Hz~8KHz
Accuracy±2.0dB
Frequency weightingA frequency weighting
Time weightingFAST:125ms/ SLOW: 1s
Microphone1/2 inch electrets condenser microphone

High/low reading

indication

﹥100dB,LCD displays“Hi”
﹤100dB,LCD displays“LO”
Temperature range-20℃~70℃/-4℉~158℉
Temperature accuracy±1.5℃/2.7℉
Resolution0.1
Data update300ms
Battery lifeat least 60 hours

Enable/Disable

Auto power off

The meter shuts off automatically after 15 minutes inactivity under auto

power off mode, disable auto power off is available

Battery3*1.5V “AAA” batteries
Operating conditions-20℃~60℃/-4℉~140℉,10RH%~90 RH%
Storage conditions-20℃~60℃/-4℉~140℉,10 RH%~75 RH%
Dimensions144*56*30.5mm
Weight73g

 

 

6. Meter description


1. Windscreen microphone cover
2. LCD Display
3. Hold button
4. Power on/off button
5. MAX/MIN
6. Fast/ Slow selection key

7. Nameplate
8. Battery compartment

 

7. LCD display description


1. Data hold Icon
2. Auto power off Icon
3. Temperature readings
4. Sound level readings
5. Fast / Slow Icon
6. Hi / Lo Icon
7. Frequency weighting Icon
8.T emperature unit Icon
9. Low battery Icon
10. MAX/MIN Icon

 

8. Notes


1) This meter has already been calibrated before delivery. Do not revise the calibration parameters without professional personnel and device.
【Note】All products are well calibrated before delivery. Recommended recalibration cycle: 1 year..
2) Repairs or servicing not covered in this manual should only be performed by qualified personnel.
3) Wipe the unit with a dry soft cloth periodically. Do not use abrasives or solvents on this instrument.
4) Remove the battery when the meter is to be stored for long periods of time to avoid battery leakage.
5) when the battery is low,LCD display,A new battery is needed.
6) Do not store or operate the meter in high temperature or humidity.
7) Wind blowing across the microphone increases the noise measurement. Use the supplied windscreen to cover the microphone when appliance.
8) Keep microphone dry and avoid severe vibration.

 

10. Accessories:


1. User's manual
2. 3*1.5V AAA Battery
3. Windscreen

Hot Products

Anti Shock Digital Smart Multimeter Auto Ranging 9.999nF 99.99nF Description: 1.1.1 When using the ...
Manual Range 1000V Digital Smart Multimeter Sine Wave Signal RMS Measurement Manual Range 60Hz ...
LCD display True Rms Digital Smart Multimeter Anti High Voltage Circuit Description: True RMS The ...
LCD Digital multimeter DC AC Voltage Diode Freguence multimeter Volt Tester Test Current Follow the ...
Lightweight 600V DC Auto Ranging Digital Multimeter 9999 Counts Display Technical indicators Ambient ...
1000V DC 0.01V 600V AC 19999 Counts Electrical Digital Multimeter True RMS Voltage Meter Technical ...