Home Companies Top Beauty Technology Co.,Ltd

New arrival F3AL250V / 220V / 50Hz Cryotherapy Machine with 8 inch Monochrome touch screen

Top Beauty Technology Co.,Ltd
Active Member

Contact Us

Address: Room407,Unit3,Building1,Shangaoshiji,Xisanqi,Jiancaicheng West Road,Haidian District,Beijing,China

Contact name:

Inquir Now

Top Beauty Technology Co.,Ltd

New arrival F3AL250V / 220V / 50Hz Cryotherapy Machine with 8 inch Monochrome touch screen

City & Province beijing beijing
Categories Other Beauty Equipment
InquireNow

Product Details

 

New arrival F3AL250V / 220V / 50Hz Cryotherapy Machine with 8 inch Monochrome touch screen

 

(Small) Handle is Alternative      (Big) Handle for Standard Match

Photo of Head(Cold+Vaccum+Light)

Remarks: Small handle is alternative head, the machine's Standard configuration just match one big handle. Clients can purchase the small handle if yours need it. The price we quote you not includes the price of small handle. We can offer you more details for them by mail if yours want to more details.Theory with Photos

Operate Interface Instructon

Fig2. Choose Language in English

Parameter

 

1.Machine Measure:49.5CMX32CMX52 CM

2.Outside Package:70CMX60CMX40CM

3.Light wavelength: 492~455nm

4.Voltage:220V/50Hz or 110V/50Hz or 110V/60Hz;

5.Touch Screen:8 inch Monochrome touch screen;

6.  Power Consumption: ≤400W;

7.  Cooling device output temperature: 5 degree~-16℃ degree

8.  Cooling device output pressure: 0-100Kpa

9.  Cooling liquid: pure water, with 4litres

10.  Default working time: 0-60 minutes

11.  Fuse size: F3AL250V

12.  Net Weight: 28KGS, Gross Weight: 45KGS

13.  Relative Humidity: 85%

14.  Atmospheric pressure:88KPa ~110KPa

 

Accessories List

1. Power supply line          1pc
2. Handle support              1set
3. Handle Support screw:   1pc
4. Cooling liquid tank         1set
5. Cooling handle               1set
6. Screwdriver                  1pc
7. User Manual                  1copy
8. Overflow water pipe       1pc

Technical background

Excessive body fat can damage people's appearance and athletic ability, may also cause various diseases. Excessive adipose tissue may be located in various parts of the body, such as: thighs, buttocks, abdomen, knee, back, face, arms and other areas. And excessive fatty tissue will form a honeycomb of ugly appearance. Excessive body fat may be associated with health risks, and therefore the need for effective control or elimination of excess fat approach.

To diminish the stubborn body fat, in addition to the use of RF heating, laser-assisted liposuction and high-intensity focused ultrasound to speed up their metabolism, you can try using fresh Cryolipolysis technology to thin layer of fat, thereby achieving self-cultivation and plastic shaped effect.

The latest Cryolipolysis technology is opposite to the way of heating which than other non-invasive means of new and more effective methods. A revolutionary new concept of fat soluble, It has proved it is major breakthrough technology for body reshaping, dissolving fat when it has been put to use.

For which a reasonable diet, regular exercise but still throw off the fat of the local people, the latest technology Crylipolysis technology condensate is a godsend. Whether it is a relatively dense area of fat, smaller parts, such as hips above the waist on both sides of relaxation of the fat, belly and back fat, the fat soluble refrigeration technology can produce stunning results.

 

Blue Light has a relaxing effect, all heat-related illnesses and need to Blue treatment, conditioning the muscles, ligaments and tissue contraction, quiet and modest results.

 

Cryolipolysis Theory

Cryolipolysis cool shape machine is a new, non-invasive way to gently and

effectively reduce fat in targeted areas of the body that results in a noticeable,

natural-looking fat reduction in the treated areas. Triglyceride in fats will b

converted into solid in particular low temperatures. What makes the

Cryolipolysis cool shape machine procedure different is that it uses advanced

cooling technology to selectively target fat bulges and eliminate fat cells

through a gradual process that does not harm the surrounding tissues. This

procedure can reduce unwanted abdominal fat, love handles (flanks), and

back fat.

When fat cells are exposed to precise cooling, they trigger a process of natural

removal that gradually reduces the thickness of the fat layer. And the fat cells

in the treated area are gently eliminated through the body’s normal metabolism

process, to eliminate unwanted fat.

Throughing the freezing effect, remove the fat cell triglyceride off heat, and will

remain at 4 ℃, so the cold coagulation, and therefore premature aging and death. Fat cells in the cold, it will start clearing the natural decomposition process, so that gradually thinner fat layer. Through the normal metabolic processes, decreasing the fat layer, to achieve the purpose of partial melting fat.

Fat cells can be significantly reduced, the fat layer also will become thinner, so that the fat blocks will be killed one by one.Cooling Skin protection while lifting and tightening.The contact cooling of the handpiece surface regulates the temperature of the skin and protects fine dermal structures, realizing the fast body-reshape effects while tightening skin!

Remarks

It need fill in 4.5 L water when you start use the machine, the water tank max with 5.0L water, but we required just 4.5L water.

If you want to transport machine from one office to another office, you muse be sure to drain out of the water from water tank. Then fill in with 4.5L water before you use it again.

When you transport the machine from one place to other place, you must drain the water off from the machine, in the back of machine, there are three holes, the upper one is for fill in water with a funnel and pipe, in the middle of machine, there is connector or hole for overflow water. As long as you fill in 4.5L water, it won't overflow from the hole. The below of the machine, it is the hole for drain

 

off water, you just need open or rive the black screw, the water will flow out from the machine, or rather from the water tank.

 

When you press the power button, the machine starts to work, especially the water pump. Therefore, the machine requires fix the handle piece before you use it, and also use the four screws to fix it which we have offered with the machine. Otherwise, the water will flow out from the machine. Or rather from the two holes which connect with handle piece. As you see the user manual, there are three holes and one connector in the handle pieces, two holes are for water cycle system, one hole is for vacuum, one connect is for cold and LED function. And also in the machine which connect the machine.

 

 

Treatment Setting

1.   One part of a working time between 30 to 50 minutes (depending on the capacity of the human body set).

2.  For the cellulite removal for the parts of body, each time just can only be for a cellulite removal for one part, regarding the Cellulite of waist, if you want celluite removal for the whole waist, it need to receive multiple treatments to complete items for what your want.

 

3.   Within 2 or 3 months, the same position after accepted the first course treatment to undergo another course of frozen fat soluble, it can reduce the extra fat layer thickness, Continue twice received treatment to dissolve fat plus freezing effect, but continued to repeat the accepted treatment at random is not recommended .

 

4.     The cryolipolysis treatment designed for localized hypertrophic fat accumulation area, physical healthy people, but not suitable for Overall obesity. Treatment mainly for a particular part, such as waist fat, belly and back, and other local cellulite. Treatment is not omnipotent and can not cure obesity, it can not replace liposuction or other invasive therapies. A Substantial weight loss should be through a balanced diet and do regular exercise; cryolipolysis treatment can only be carried out for extra fat.

 

 

Skin Antifreeze

Qualified antifreeze should be used during the treatment, to avoid frostbite when temperature lowers to the 0 to -20 degree. Consumables, purchase on your own.

Operation Process

1.  Check the thickness of the fat

2.  Clean treatment area; Clear the hair of the treatment area

3.  Mark the size of treatment area

4.  Use antifreeze on the treatment area

5.  Paste antifreeze membrane at treatment part.

6.  Patients receiving the treatment should be sitting Make upper body and lower limbs to 90 degrees.

7.  According to the patient endurance of fat thickness and size selection suction.

8.  The refrigeration device gently dissolve fat absorption treatment site, press the” START” button.

9.  Starts suction instrument itself will remain unchanged.

10.45-55 minutes after treatment with model , press the control button in the screen, to stop the suction. Then use the other five models

with for massage with 5 minutes according to the feeling of clients.

Hot Products

New Arrival Red / Blue / Green / Yellow LED Light PDT Skin Rejuvenation machine General Introduction...
Frozen fat dissolving instrument Portable cryolipolysis cooling device slimming cryotherapy machine ...
New arrival F3AL250V / 220V / 50Hz Cryotherapy Machine with 8 inch Monochrome touch screen (Small) ...
New design home use PDT skin rejuvenation machine with LED light for skin collagen bed CE red / blue ...
Detailed Product Description Body Shaping Underwear Body Shaper Slimming Bodysuit Body Shaper Corset ...
Detailed Product Description High Quality Body Shaping Underwear Sets Women Seamless Corset Slimming ...