Home Companies Top Beauty Technology Co.,Ltd

cavitation+Tripolar RF+ Monopolar RF for weight loss cellulite loss beauty equipment

Top Beauty Technology Co.,Ltd
Active Member

Contact Us

Address: Room407,Unit3,Building1,Shangaoshiji,Xisanqi,Jiancaicheng West Road,Haidian District,Beijing,China

Contact name:

Inquir Now

Top Beauty Technology Co.,Ltd

cavitation+Tripolar RF+ Monopolar RF for weight loss cellulite loss beauty equipment

City & Province beijing beijing
Categories Other Beauty Equipment
InquireNow

Product Details

cavitation+Tripolar RF+ Monopolar RF for weight loss cellulite loss beauty equipment machine

Product introduction

1. Specification:

TFT LCD Display 8 inch true color touch screen
Technology Cavitation+(Monopolar RF+Tripolar RF)
Cavitation frequency 40KHz
Cavitation Max Power 80W
Tripolar RF 1MHz (output frequency);
Monopolar RF 1MHz (output frequency );
Handpieces 4 pieces
1).Monopolar RF head
2).Tripolar RF head (one big, one small)
3).Ultrasonic cavitation head

Voltage  220±10 V AC/110±10 V AC 50/60Hz
Size 49cm×31cm×25cm(L×W×H)
Weight 15KG
2. Product features

1.1.1 Body shape instrument pick the Israel hole blasting fat technology, RF technology and vacuum melting fat pinch drainage techniques in one set with multi-body sculpting, at the same time have a 40K strong sound wave system, and  the strong sound waves can produce a liquid implosion effect, which is the wave of expansion and compression then make the liquid in the formation of a large number of micro-voids, these voids are gases and steam , With the compression cycle, the strong sound wave cause pressure effects for liquid molecules, and in the expansion cycle, resulting in negative pressure effect.

In fact, inside the liquid or biological tissues exist a cohesive, in the low density of fat cells, molecular bonding will be weak, and the strong sound waves can generate a low negative pressure which can produce organizational gap that in physics known as "hole phenomenon."

The direct affects of implosion which micro-gap inside and outside the Cells results in enhancing the molecular motion, so as to achieve a high energy level, eventually lead to the breakdown of fat cells.

Mono-polar and tri-polar RF system, not only effect of the skin but also the subcutaneous fat, so it can be widely applied to the face, neck wrinkle removal and tighten, as well as other parts of the body to lose weight, improve the orange peel-like skin , postpartum abdominal tightening and so on.

It is the radio frequency heat energy through the epidermal and stimulate the epidermal  deep tissue, make the subcutaneous tissue produce immediate tighten the collagen fibers and regeneration. The skin becomes plump smooth again, restore the original flexibility, while the heat effect, can enhance blood circulation, improve microcirculation and inhibit sebaceous gland produce, which results in eliminating wrinkles, shrinking pores, tighten skin, removal Acne.

While the vacuum system was first used in medicine to be cured scars, liposuction post-operative recovery, as the technology development, and then someone found that the deep massage is equivalent to a passive aerobic exercise, it has unique effect of expulsion of toxin in the body and improve the orange peel tissue .

body sculpting instrument is a novel, non-surgical, non-invasive, painless, safe and efficient beauty equipment.

1.1.2 The instrument is equipped with four hand-held probe, which can be accordance to the different parts of the treatment needs to select the proper size and treatment system.

1.1.3 This unit pick intelligentized control, touch screen operation, visual interface application, which ensure the guest easy to learn and safely use.

1.1.4 This unit use continuous output mode, which accordance with acting on the human body parts and operational methods for enhancing operation. Energy output is divided into 50 files, Ⅰ ~ 50 files of energy from low to high, according to the needs of physical therapy choose to use a different stall; acting on the body's energy value range is from 1J to 50J, when in operation, users can accord to the patient’s capacity to adjust the energy, increase or decrease in volume of 1J.The working hours are dynamic countdown display; Each program is sorted, refined, and processed by the highly experienced physicians, which based on several years of clinical nursing experience, and combined with the scientific theory of human life. And then be abstracted into a certain law of mathematical functions, and process by computer.

1.1.5 For the convenience of users, we design interactive interface with automatic countdown and remind function.

1.1.6 This unit use SCM control and LCD display,

 The main components pick large scale integrated circuits, clear vision and high reliability. The strong sound wave system uses the best 40K ultrasonic frequency for body shaping, This frequency can be effective for treat stubborn cellulite and orange peel fat, which use sound waves of the cavity effect, acting on the fat group and break them down and then absorbed by  lymphatic system. RF system uses 1MHz RF frequency, which can make cells produced a strong resonance of water molecules rotate and produce heat by the friction. Thereby heat up to the collagen and fat cells for the purpose of heating. Vacuum system uses adjustable pulse control, and thus can be able to mimic the effects of high-level massage doctor

1.1.7 This unit use modular design and has clear structure ensure the user easy to install and maintain.
3. Application:

cavitations:blast fat on arm, abdomen, buttocks and thigh , and improve the skin.

6.3RF:       cheek, lower jaw, neck skin tightening; nasolabial fold improvement; waist and abdomen, limbs, weight loss; hips, big legs, orange peel-like skin improvement.

4. Taboo:

a. Pregnant and in the menstrual period women are prohibited use in abdomen; such as fever, suffering from infectious and acute disease; have heart disease, config  heart pacemaker, severe high blood pressure, cancer disease, asthma, deep vein thrombosis, varicose veins , goitre, cancer, epilepsy and other patients; has hemorrhagic disease, trauma, vascular rupture, skin inflammation, skin disease patients and pregnant women; immune system dysfunction, etc. over-sensitive to the current person can not use this device

b. If feeling unwell, do not use this device. Prohibited in the ears, nose, eye, throat and other parts used; when use the cavitation must pay attention to: female uterus, breasts, genitals, medical shaping the site, there are metal parts of the body and the filler parts, can not use this device. If the skin feels any discomfort or pain, do not use this device. Can not operate in the back, we must avoid the bone bits.

c. The body buried in hearing aids, heart pacemakers, artificial hearts

and other around medical electronic devices are banned on the use;

d. Children under 12 years old
1.3 Product structure

1.3.1 The appearance structure as the picture shows, This unit main include: main unit, handle(contain Probes) and Cable.

Treatmenthe1       

 Treatment head2

Power line

Treatment head3

1.3.2 The probe is divided into four kinds, see below table.

Table 1

Probe number

Probe size

Main acting parts

1#cavitation

Φ78

Limbs , abdomen and buttocks

2#6RF(big)

Φ65

bigger parts of body

3#3RF(small)

Φ45

small parts of body

1.4 Main Specification

TFT LCD Display

8 inch true color touch screen

Technology

Cavitation+(Monopolar RF+Tripolar RF)

Cavitation frequency

40KHz 

Cavitation Max Power

80W

Tripolar RF

1MHz (output frequency); 

Monopolar RF

1MHz (output frequency );

Handpieces

4 pieces

1).Monopolar RF head

2).Tripolar RF head (one big,  one small)

3).Ultrasonic cavitation head

 

Voltage 

220±10 V AC/110±10 V AC 50/60Hz

Size

49cm×31cm×25cm(L×W×H)

Weight

15KG

5.Install and use
2.1.1 Plug the power line into the power and  unit

2.1.2 According to different needs, when replace the probes of different sizes, hold down the interface to pull out the end of the replacement, and then in accordance with the direction of the gap can be connected.

2.1.3 when in Operation, the probe face must be close to the skin, press the default settings of the parameters from the minimum to begin, and then adjust based on individual level to gradually increase the role of energy and time.
2.2 power on

For security, please turn the power orderly ; First, make sure you provide 3-pin power outlet is good and reliable . Second, the instrument's power plug and power outlet is a closely contact. Finally, ensure the two prerequisite conditions are correct, please turn on power switch behind the unit. After turn on the switch, then turn on the power key. The host will be powered on and go into the user interface.

After Power on, the boot screen will display the company LOGO , point at any icon into the language selection interface, such as below graphics shows:

After choosing the language then into the main menu system interface, as below figure shows:

2.3 choose treatment system then into the operation interface shown in Figure

   Adjust the parameters then to begin treatment.

2.3.1 Energy output is 50 files when in working state and adjustable from low to high
6 Warning
3.1 Main unit

3.1.1 Please use the random allotment of three-core power cord and prohibit using two-core power cord. middle of the core in Power plug must be reliable to ground.

3.1.2 Inoperable areas: the eye, ear and other parts of taboo.

3.1.3 Avoid in strong magnetic fields and radio waves occurred in the custody places, do not use in the bathroom, kitchen and other places severe moisture and dust or high temperature storage areas.

3.1.4 Apart the host is strictly prohibited, in addition to the company's authorized officer, others should not open the lid; prohibit non-professional staff carry out repairs; otherwise own risk.

3.1.5 Unused for more than six months and re-use have to accept check-up services, in order to long-term use of this product, please buy regular services in shop.

3.2 handle

3.2.1 When the hand-held pieces in the event of the failure or damaged and need to replace, please unplug the hand-held pieces of sockets. When install the handle please accordance to the direction of the connector on the chassis, and inserted in the end force to ensure that the probe connector with the socket are close. During the installation process please avoid holding pieces fall on the ground.

3.2.2 Dismantling or transformation of hand-held items is strictly prohibited.

3.2.3 Do not strongly impact or percussion hand-held pieces.

3.2.4 when in operation, the probe should be completely  contact with the skin, and then begin to operate(start-point touch screen).

3.2.5 If replace person after each treatment, the energy of the interface must be returned to the lowest setting, and then  adjust the energy accord  to each individual level and the degree of sensitivity!

3.2.6 Others functions are prohibited except this user manual specified..

3.2.7 Probes clear:Available medical alcohol scrub.

3.2.8 Probes maintain:If do not need to use the unit, please turn it down to prevent the probe in oxidation.

3.2.9 The lifetime of hand-held pieces is 2000 hours, after the expiration of delay, please buy replacement from my company.
3.3 touch screen

3.3.1 Do not use sharp instruments impact touch-screen.

3.3.2 Do not let cosmetic or other dirt attached to the touch-screen

3.3.3 Do not pour liquid substance on the touch screen

3.3.4 Prohibit alcohol or detergents and other cleaning agents scour the touch screen, For cleaning, use a soft clean cotton  cloth for light Sassafras.

4 Consumables

4.1 Conductive gel is for Consumables

4.2 The above Consumables can be bought from our company..
7. Simple malfunction and solved method

When the equipment fails during use, the user can diagnosis and exclude some simple failures by this below guide, if still not resolved, please call our customer service for further consultation   

5.1 Can not boot

confirmed AC is the correct access, the power plug is inserted tight, the power switch is all open, fuse whether it is in normal.

5.2 Touch-screen invalid clicks because of below reasons:

a. May be touch screen is pressed, gently point a few on touch screen and then reboot;

b. touch-screen positioning is incorrect or breakdown , make touch screen calibration, please contact our customer service to solve the problem.

5.3 feeling unwell in operation

Re-select the treatment system, ensure the applies to you.

5.4 Touch-screen appears abnormal crash

Please turn off the power supply, after 2 minutes reboot the Machine

5.5 Abnormal situations or failure can not be excluded

Please contact the local offices, and show the purchase date, we will be in 24 hours give reply for your question.

5.6 Replace fuse method (their position is as the figure show)

5.7.1 As shown in Figure 6.7-1 refers to the location of the arrow type and use screwdriver to pry out the fuse holder.

5.7.2 As shown in Figure 6.7-2 put the fuse into the slot fuse holder of installation. power supply for the AC220V, the fuse specifications: Tac250V/8A;when use Ac110V power supply, the fuse specification is: Tac250V/15A

5.7.3 Put the fuse holder into sockets.

Hot Products

Newest slimming machine with cavitation&mult-ipoar rf&camera etc for weight loss cellulite loss 1. ...
100w cavitation +vacuum+tripolar rf +28K ultrasound head LED light slimming machine Super Fat ...
2011New arrival Cavitation RF Vacuum Ultrasound slimming machine Srtong sound wave fat system 1. ...
cavitation +vacuum+ Iridescent Body RF Probe + Facial RF head for weight loss cellulite loss face ...
cavitation+Tripolar RF+ Monopolar RF for weight loss cellulite loss beauty equipment machine Product ...
Cavitation Vacuum ultrasound slimming machine ​with rf head Ice Rediofrequency import cavitation ...