Touch Screen Switch Load Cabinet For Self Ballasted Lamp Loads IEC60669-1

Country/Region china
City & Province guangzhou guangdong
Categories Other Measuring & Analysing Instruments
InquireNow

Product Details

 

 

Self-Ballasted Lamp Switch Load Cabinet For Self Ballasted Lamp Loads IEC60669-1
 
Standards For Self-Ballasted Lamp Switch Load Cabinet:
 
IEC60669-1:2007 "Switches for household and similar fixed-electrical installations - Part1:General requirements" clause 19.3
 
Test Principle For Self-Ballasted Lamp Switch Load Cabinet:
 
Switches intended for self ballasted lamp (SBL) loads shall withstand, without excessive wear of other harmful effect, the electrical and thermal stresses occurring when controlling self ballasted lamp circuits.
The purpose is to check whether the switch has continuous flashover, whether the contacts are welded, closed or disconnected for a long time, excessively worn or otherwise.

 
Technical parameters For Self-Ballasted Lamp Switch Load Cabinet:
 

Test Channels1 or 2 or 3 channels can be customized, independently output
Electrical Control MethodTouch screen + button control, digital display
Voltage Display Value0~300V, accuracy level 0.5
Power Display Value0~9KW,accuracy level 0.5
Output Voltage0-280V adjustable, ensure test voltage to be 250V~
Preset Rated Voltage of SwitchEach channel 250V~, rated current 10A,13A,16A,20A are optional
Working Parameter SettingAll parameters are set according to 250V~, including W, I peak, I2t and surge current waveforms.
Calibration Function

Each set of equipment provides a closing control device (select the “calibration” function on the touch screen), and each time it is conducted at a 90-degree angle, this function can be used for initial adjustment and calibration verification of the equipment.
(The calibration method is to extract the current waveform from an external oscilloscope, and then use the calculation method to obtain the I2t value, the oscilloscope is provided by client)

Protective FunctionLong time breaking / long time conduction protection, protection time: 1 ~ 99S can be preset, the equipment will be stopped and alarm will be given out when protection occurs.
Use Environment

Power supply: AC220±5%/50Hz,10KVA
Place of use: Atmospheric pressure 80~106kpa;
Environment temperature:5~40°C;humidity(20~80)%RH;
No violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gases, good heat dissipation

 
Structure For Self-Ballasted Lamp Switch Load Cabinet:
 

The load cabinet uses an integral steel structure frame and a Toyota white seal plate. The control panel is in the upper part of the equipment, there are external power switch, voltmeter and power display instrument, alarm and touch screen, resistor and capacitor load combinations, AC contactors and relays. There are terminals in the lower part of the load cabinet, which is connected with the specimen through the cables to output current and voltage during the detection process.
Main features:
1. The load conditions required by the standard has been preset before factory. As long as the test voltage is adjusted to 250V~, operator presses switch button corresponding to the rated current of the switch to be tested, then the rated power, shock waveform, Ipeak and I2t meet the corresponding requirements of the standard.
2.The input voltage and output power can be digital displayed, the surge current can be observed on the pointer current meter.
3. There are 3 working stations, 3 switches can be tested at the same time.
4. With calibration mode and calibration dedicated port, built-in 90-degree closing plate, easy for measuring output waveform, Ipeak current value and I2t energy value, thus, fully meets the standard requirements of calibration.
5. The device is equipped with a voltage regulator, which can achieve the voltage of 250V~ required by the switch test without external voltage regulator.
Dimensions of the equipment: approx.: 800 × 800 × 1800 (mm) W × D × H, weight: 200kg
 

 

 


























Hot Products

Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...