Home Companies Sinuo Testing Equipment Co. , Limited

Cookerwares Coating Scratch Resistance Testing Equipment BS EN 12983-1

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Cookerwares Coating Scratch Resistance Testing Equipment BS EN 12983-1

Country/Region china
City & Province guangzhou guangdong
Categories Other Home Product Making Machinery
InquireNow

Product Details

 

BS EN 12983-1 Scratch Resistance Tester For Testing Cookware Scratch Resistance 

 

Structure for Scratch Resistance Tester:

 

The device uses the pencil nib to compare the scratch resistance of the coating; Apply 4&8N pressure to the pencil; Insert the pen core into the hole where the hole is 45°, then the pencil nib completely touches the bottom coating of the pot, and then draw a 2~5cm line on the coating; Judge the effect by the li:202nes drawn.

 

Standards for Scratch Resistance Tester:

 

BS EN 12983-1: 2020 clause 8.4.2, 8.4.3 and Appendix K.

 

Main specificationsfor Scratch Resistance Tester:

 

Power supplyAC220V, 50HZ
Test station1
Scratch angle45 °
Test massOne of each 4N, 8N
PencilOne of each HB,2H,3H,4H,5H
Drive modeElectric + eccentric wheel mechanism
Test speed0-10 times/min, adjustable
Scratch length20~50mm, adjustable
DimensionWDH=900×500×700mm

 

Heating platform DB-2EFS:

 

Graphite heating plate
Product modelDB-XEFSDB-1EFSDB-2EFSDB-3EFS 
Power supply/powerAC220V/50Hz 
The whole machine power1.6KW2KW3KW4KW 
Display modeLCD display 
Operating temperature50-420℃ 
Temperature control precision of instrument±1℃ 
Temperature uniformity3% 
Heat the size300*200mm400*280mm450*350mm600*400mm 
The plate materialgraphite 
The plate thickness12mm 
bearing5kg 
The net weight9kg13kg18kg30kg 
Product size30*35*20cm40*43*20cm45*50*20cm60*55*20cm 
 
Operations steps:
 
1 Put the heating platform on the equipment, and power on it by inset it’s plug to the socket on the equipment.
2 Put the sample cookware on the heating platform.
3 Put the sharpened pencil into the fixture with an included angle of 45°, with the sharpened end facing the surface of the cookware, and tighten the screw to fix the pencil.
 
 
4 Select the load according to the requirements, 4N is shown in the left figure below, and a load accessory is added to make 8N.

5 Power on the equipment, select the test according to your requirements.

Ambient temperature test: Test at room temperature, select 8N load;

High temperature test: Turn on the power of the heating platform to start heating, set the temperature of the heating platform (standard requirement is 200℃), and select 4N load.

Note: During the high temperature test, when the temperature display of the heating platform reaches the set value, press the start button to start scraping, and observe whether the speedometer under the panel is the speed required for the test. If not, you can adjust the speed controller on the panel.

6 Set test times.

7 After the test is completed, check whether the cookware meets the requirements according to the standard.

 

Maintenance:

 

1 Before working, please check whether the fasteners are loose, and make sure that the loose fasteners are locked.

2 Do not touch the surface of the heating platform when heating to prevent burns.

3 Please remove the weight when it is not working.

4 Please cut off the power when not working.

 

Hot Products

Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
5RT Air Enthalpy Laboratory Air Conditioner Energy Efficiency Performance Lab System overview This ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...