Home Companies Sinuo Testing Equipment Co. , Limited

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60332-1-2 Single Electric Cable Or Optical Fibre Cable Vertical Flammability Test Device

Country/Region china
City & Province guangzhou guangdong
Categories Cable Manufacturing Equipment
InquireNow

Product Details

 

IEC60332-1-2 Single Insulated Wire Vertical Flammability Test Apparatus For Single Electric Cable Test

 
Overview:
 
The flammability chamber testing adopts integral type inlet ignition system, the combustion time delays 0.1s thus to ensure the sufficient time for gas burning. It also has matte black background, multi-functional flame measure gauge, full stainless steel chamber body, large observation window, imported high precision digital indicator, nice appearance. It is suitable for vertical burning test of a single electric wire, cable or optical fibre cable to determine the burning characteristics of its insulating material. 
   


 

                                    
Principle:
 

The flame test apparatus meets the requirements of :
IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus”

IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame”

IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles”
and etc.
 

Test principe: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.


Technical parameters:

 

Use EnvironmentPower supply: single-phase AC220V±10%, 50/60Hz
Ambient temperature: 10℃~35℃ Relative humidity: 30%~90%
Control operation modeElectrical control, button operation (PLC control can be optional)
Blast burner standardIEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm,made of brass
Gas flow and gas category

Mixture gas: 650±30mL/min propane &10±0.5L/min air.
Dual flow meter adjustment

Flame application time9999X0.1S
Flame application angle

Tilt 45°±2°, Adjustable

Test flame calibrationTemperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°C

Distance between the bunsen burner port to temperature measuring copper block:95 mm

Flame height: Inner flame:55±5mm, outer flame:180±10mm
Temperature rise time from 100±5°C to 700°±3°C 45±5s
Combustion chamberWDH=300×450×1200±25mm
Test sampleLength: 600±25mm, distance from the bottom:50mm
Fixed horizontal support of the sample2, distance:550mm
Overall dimensionsWDH=700×450×1350mm, weight about 120kg
 
How to position of test piece?
 
The test piece shall straightened and secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal, so that the distance between the bottom of the upper support and the top of the lower support is (550±5)mm. In addition, the best piece shall be positioned so that the bottom of the specimen is approximately 50mm from the base of the enclosure. The vertical axis of the test piece shall be arranged centrally within the enclosure (i.e. 150mm from each side and 225mm from the rear).
 
 
Sinuo techincal team well understand flammability testing requirements. Except supply various flammability test chamber , Sinuo can also have the ability to provide solutions for building the entire combustion laboratory. Sinuo team can well plan the the combustion laboratory's equipment layout , ventilation and exhaust, gas pipeline, safety measures, etc.
 
 

Hot Products

IEC 62552 Refrigerator Freezer Energy Efficiency Lab Overview: This refrigerator performance lab is ...
Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...