Home Companies Sinuo Testing Equipment Co. , Limited

IEC 60884-1 Annex C Plug Gripping Test Apparatus With Reference Plug

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60884-1 Annex C Plug Gripping Test Apparatus With Reference Plug

Country/Region china
City & Province guangzhou guangdong
Categories Solar Chargers
InquireNow

Product Details

 

IEC 60884-1 Annex C Plug Gripping Test Apparatus

 

Product information:

This device is used to verify the plug clamping test. It conforms to IEC 60884-1 Annex C alternative gripping tests figure C.2, the reference plug as per C.1 also included.

 

Technical parameters:

1. A reference plug required: the reference plug should be made according to IEC 60884-1 Annex C Figure C.1.Surface roughness 0.5 μm ~ 0.8μm.

2. Sample fixture:1 set
3. Test support: 1set;

4. Digital force gauge: 1 set, 0~200N, accuracy 0.5 level , it has a reliable connection method to be connected with reference plug and test plug.

 

ItemSpecifications
A reference plugThe reference plug should be made according to IEC 60884-1 Annex C Figure C.1. Surface roughness 0.5 μm ~ 0.8μm.
Sample fixture1 set
Test support1set
Digital force gauge1 set, 0~200N, accuracy 0.5 level , it has a reliable connection method to be connected with reference plug and test plug.
 

Operation Steps:

1. Prepare the test plug, clamp the test plug with the sample fixture, the plug surface is flush with the plate’s bottom surface, the test plug pins go through the hole of the plate, the rod goes through all the holes of the plug pins,then hook the digital force gauge on the top ring, pull the force gauge and record the force value three times.

2. Clamp the reference plug with the sample fixture, the reference plug surface is flush with the plate’s bottom surface, then the rod goes through the hole of the reference plug, hook the digital force gauge on the top ring, pull the force gauge and record the force value three times.

3. Compare the force values of step 1 with the force values of step 2 as per IEC 60884-1 Annex C .

 

 

 

Hot Products

IEC 60312-1 European Standard Alternative B Vacuum Cleaner Performance Test Bench System overview: ...
Comprehensive Energy Efficiency Test System for Washing Machines Refigerators Freezers Water Heaters ...
IEC 60312 Vacuum Cleaners Comprehensive Performance Test System System Overview: The system is ...