Home Companies Sinuo Testing Equipment Co. , Limited

15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

Country/Region china
City & Province guangzhou guangdong
Categories Polishers
InquireNow

Product Details

15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer
 
Overview:
 
This sieries of battery and cell charge discharge testing equipment meets the requirements of lithium ion battery or lead acid battery pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.
 
Technical Parameters:
 

Project index

Parameter index

Input PowerAC 220V±10%/50Hz (or can be customized)
ResolutionAD:16bit; DA:16bit
Input Resistance≥1MΩ
Input Power

1722W (for 15V model)
1620W (for 30V model)

Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
Channel Control ModeIndependent control
VoltageVoltage Range Per Channel

75mV-15V (for 15V model)
0.15V-30V (for 30V model)

Minimum discharge voltage0V
Accuracy± 0.1% of FS
Stability± 0.1% of FS
CurrentCurrent Range Per Channel50mA~10A
Constant voltage cutoff current20mA
Accuracy± 0.1% of FS
Stability± 0.1% of FS
PowerOutput Power Per Channel

150W (for 15V model)
300W (for 30V model)

Stability± 0.2% of FS
TimeCurrent Response TimeTime of current rising to 10A is 20ms
Step Time Range1s~365*24 hour, Time Form Support 00: 00: 00:000(h, min, s, ms)
Data RecordingRecord ConditionTime△t: 100ms

Voltage△U:30mV (for 15V model)
Voltage△U:60mV (for 30V model)

Current△I: 20mA
Record Frequency10Hz
ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant current and constant voltage of the battery pack
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
Pulse ModeCharge modeConstant current mode, Constant power mode
Discharge modeConstant current mode, Constant power mode
Min. pulse width500ms
Number of pulseSingle pulse step supports 32 different pulses
Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
Cutoff conditionVoltage, relative time
DCIR TestSupports custom point retrieval for DCR calculations
CycleLoop Measure Range1~65535 times
Max Steps Per Loop254
Nested LoopWith nested loop function, max support 3 layers
ProtectionSoftware Protection
  • Power-down Data Protection
  • Off-line Testing Function
  • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
Voltage and current detection samplingFour-wire connection
Noise<85dB
DatabaseMySQL Database
A Means of Communication of Upper MachineTCP/IP Protocol
Data OutputEXCEL2003,2010,TXT
Communication InterfaceEthernet Port
Main Channels No. Per Unit

8 (for 15V model)
4 (for 30V model)

Leakage Current

0.015mA (for 15V model)
0.03mA  (for 15V model)

Dimensions12U chamber, W*D*H: 600 *600*740(mm)
FixtureTo be determined
 


Equipment Working Environment :
 

Project index

Parameter index

Working Temperature Range10℃ ~ 40℃1
Storage Temperature Range-10℃ ~ 50℃
Working Environment Relative Humidity Range≤70% RH (No condensation)
Storage Environment Relative Humidity Range≤80% RH (No condensation)
Auxiliary channel voltage range (optional and customized)-5V~5V

Auxiliary channel voltage accuracy
(optional and customized)

±0.1%ofFS
 

The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.
 




















Hot Products

IEC 60879-2019 Ceiling Fans Environmental Test Chamber Energy Efficiency Testing Lab Overview: This ...
IEC 60879-2019 Electric Table Fans Floor Fans Energy Efficiency Test Chamber Overview: This test ...
IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab Product ...
IEC 60436 Dishwasher Performance Test System Energy Efficiency Testing Chamber System overview: This ...
Customized Air Conditioner Energy Efficiency Lab Heat Pump Enthalpy Test Chamber System introduction...
IEC 60312-1 European Standard Alternative B Vacuum Cleaner Performance Test Bench System overview: ...