IEC60529: 2013 IPX7 Immersion Test Chamber With Electric Lifting Control Cabinet

 
Product Overview For IPX7 Immersion Test Chamber:
 
The IPX7 immersion test chamber is designed and manufactured in accordance with the requirements of IEC 60529:2013. Used for testing the IPX7 waterproof level of electrical and electronic products.
The complete set of IPX7 immersion test chamber is composed of water tank, electric lifting basket and control cabinet.
 
Technical parameters For IPX7 Immersion Test Chamber:
 

Chamber external sizeApproximately W 1080* D 1080*H 2300mm (including casters)
Chamber inner sizeLength 1000* W 1000* H1800mm
Max. test water depth1.8m
Observation windowTempered glass (thickness: 12mm)
Observation window width200mm
Water level adjustment methodWater inlet / drain valve, manual adjustment
Water level displayScale (accuracy 1mm)
External chamber materialStainless steel plates + Aluminum profile frame
Inner chamber material2.0mm thickness stainless steel
Electric lifting basketMade of stainless steel, controlled by electric hoist
Control methodButtons (non-PLC)
Test time0.01 second-99.99hours can be preset
Immersion depth requirements

The lowest point of enclosure with a height less than 850 mm is located 1000mm below the surface of the water
The highest point of enclosure with a height equal to or greater than 850mm is located 150mm below the surface of the water

Test contentIPX7
Power supplyAC 220V,50Hz, 1KW
 
Common Troubleshooting For IPX7 Immersion Test Chamber:
 
No.:Failure phenomenonThe cause of the failureApproach
1Equipment is powered on, but timer does not show any valueExternal power supply failsReconnect power supply
Power control breaker is offTurn on the breaker in the control box
2No action when the start button is pressedThe test time is not clearedPress “Stop/Clear” to clear time
 
 
 

Hot Products

Freezing Load Test Package for IEC 62552 Refrigerator Energy Efficiency Test Overview: The ...
ISO15502 Household Refrigerating Appliances Performance Lab 6 Stations Overview: This refrigerator ...
ISO 5151 60K BTU Computer Control Dual Code Air-Enthalpy Calorimeter System introduction: The air ...
Dryer Air Volume Test Equipment For Measure Air Volume Or Airflow Performance Of Dryer IEC 61855 ...
IEC61855 Figure 9 Dryer Air Volume Test System For Household And Similar Purposes Standards: QB...
IEC 61591: 2014 Range Hood Air Performance (Air Volume) Testing System For Pressure Efficiency Test ...