Home Companies Shanghai Shenghua Cable (Group) Co., Ltd.

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

Shanghai Shenghua Cable (Group) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.7577 Hunan Road, Pudong New District. Shanghai China

Contact name:Mayling Zhao

Inquir Now

Shanghai Shenghua Cable (Group) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

Country/Region china
City & Province shanghai hunan
Categories Other Wires, Cables & Cable Assemblies
InquireNow

Product Details

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV Used for Fixed Installation

 

Cable Application

 

Cu/XLPE/PVC/AWA/PVC power cable may be used for fixed installation indoors and outdoors in cable ducts or directly in the ground.

Technical Information

Conductor Material:Copper, IEC60228
Conductor Shape:50mm² up to 400mm² Circular
Conductor Flexibility:Stranded class 2
Outer Sheath:PVC, IEC60502
Inner Sheath:PVC, IEC60502
Insulation:XLPE (Cross-linked Polyethylene), IEC60502
Armour Type:Aluminium wires
Colour:Black
Lead Free:Yes
Rated Voltage Uo/U (Um):600/1000V, BS5467
Installation Temperature:Minimum: 0°C Maximum: 60°C
Installation Type:Outdoor Direct burial
Operating Temperature:Minimum: -15°C Maximum: 90°C
Short-circuit Maximum Conductor Temperature:250°C
Flame Retardant:IEC 60332-1 and BS EN 50265-2-1
Bending Radius:50mm² up to 1000mm² = 6 x Ø

Rated voltage:0.6/1kV Low Voltage
Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core without armor
15 x cable O.D for multi core without armor
15 x cable O.D for single core with armor
12 x cable O.D for multi core with armor

Standards: International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS, DIN, VDE and ICEA upon request

Installation

1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installation, the cable should with stand voltage test for 15min. 3.5kv D.C.

 

Hot Products

1-630mm2 Copper Conductor and Screen Single Core MV Power Cable up to 35kV Cable Application Cu/XLPE...
BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV Used for Fixed Installation Cable Application Cu/XLPE/PVC/AWA/PVC ...
BS6622 Standard CU/XLPE/CTS//PVC 6.36/11kV Single Core Power Cable Application :PVC Insulated and ...
Copper Wire Screen Aluminum Conductor XLPE Insulated Power Cable For Power Distribution 12KV ...
Single Core up to 1000 SQMM XLPE Insulated Power Cable Middile Voltage Unarmoured Power Cable ...
240 Sq mm XLPE Insulated PVC Sheath Electrical Cable LV Multi There Core KEMA IEC Certification ...