Home Companies Shanghai Shenghua Cable (Group) Co., Ltd.

Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes

Shanghai Shenghua Cable (Group) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.7577 Hunan Road, Pudong New District. Shanghai China

Contact name:Mayling Zhao

Inquir Now

Shanghai Shenghua Cable (Group) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Black Low Smoke Zero Halogen Cable LSZH Cables for Smoke Emission / Toxic Fumes

Country/Region china
City & Province shanghai hunan
Categories Control Cables
InquireNow

Product Details

LSZH Cables for Use in Applications Smoke Emission and Toxic Fumes

 

APPLICATION

 

 These power cables are used for electricity supply in low voltage installation system. They are well adapted to underground use in industrial applications with an additional mechanical protection. These cables can be fixed on cable trays, within conduits or fixed to walls.

 

CONSTRUCTION

 

Conductor Up to 35mm2: Class 1 solid copper conductor to 16mm2 Above 35mm2: Class 2 stranded copper conductor

Insulation XLPE (Cross-Linked Polyethylene) Type 2XI1 according to VDE 0276 Part 604 Sheath LSZH (Low Smoke Zero Halogen) Type HM4 according to VDE 0276 Part 604

 

Main features
1. Ordinary flame retardant cable
For Class A and Class B fire tests, the fire time is 40 minutes, and for Class C and Class D fire tests, the fire time is 20 minutes, and the charring height does not exceed 2.5 m.
2. Low-halogen low-smoke flame retardant cable
Halogen acid gas emission <100 mg/g, smoke density (transmittance) > 30%, from the group burning test, it meets the requirements of Class C flame retardancy.
3. Low smoke zerohalogen (LSZH) flame retardant cable:
Halogen acid gas all-emission 0 mg/g, pH value ≥ 4.3, conductivity ≤ 10 us/mm, toxicity index ≤ 5. From the group burning test, it at least meets the requirements of Class C flame retardancy, smoke density (transmittance) ≥
60%.
4. Oxygen barrier cable (highly-flame retardant cable)
From the group burning test, it meets and exceeds the requirements of Class A flame retardancy, and the smoke density (transmittance) is equal to or close to national standard GB/T17651-2008 and international standard IEC61034 low smoke standard.
It is especially suitable for 6 KV-35 KV medium-voltage cable frame retardancy, has not only flame retardancy up to Class A, but also has certain refractory characteristics (i.e. can still keep 2.4 Uo insulation standard after burning for 20 min).
Notes: Users can select category and class of flame retardant cable according to laying places.

 

Hot Products

XLPE Insulated PVC Sheathed Copper Power Cable 0.6/1kV Shanghai Manufacturer Type Desciption Rated ...
2core 240mm2 Copper Conductor XLPE Insulated Power Cable Armored or Unarmoured 0.6/1KV Electric ...
33KV Single Core 185mm2 XLPE Insulated Power Cable Un-Armoured Power Cable Applications: XLPE ...
Armored Electrical Cable 33KV 3 Core 185mm2 AL / XLPE / PVC Ink Printing Applications: XLPE ...
Low Voltage PVC Sheath XLPE Insulation Copper Conductor YJY Power Cable 300mm Single Core Cable ...
AL/XLPE/PVC Unarmoured Electrical Cable 12/20KV 3 Core 300mm2 XLPE Insulated Power Cable Electric ...