Product Information Of: 3051L2AA0D21AAF1

Brand3051L2AA0D21AAF1
SUPPLY

0 to 621,60 mbar

SIZEDoes not supply
Weight5KG

(1)Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.

(2)Option code M4 - LCD display with LOI required for local addressing and configuration.

(3)Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), IECEx Intrinsic Safety (option code I7), and EAC Intrinsic Safety (option code IM).

(4)Only available with C6, E2, E5, I5, K5, KB, and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, or CT.

(5)Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.

 

More options :

MR-J2S-10A

MR-J2S-10B

MR-J2S-20A

MR-J2S-20B

MR-J2S-40A

MR-J2S-40B

MR-J2S-60A

MR-J2S-60B

MR-J2S-70A

MR-J2S-70B

MR-J2S-100A

MR-J2S-100B

MR-J2S-200A

MR-J2S-200B

MR-J2S-350A

MR-J2S-350B

MR-J2S-500A

MR-J2S-500B

MR-J2S-700A

MR-J2S-700B

 

Rosemount 3051L Level Transmitter​ Information:

ModelTransmitter type
3051LLevel transmitter 
Pressure range
2–250 to 250 in H2O (–621,60 to 621,60 mbar)
3–1000 to 1000 in H2O (–2,48 to 2,48 bar)
4–300 to 300 psi (–20,68 to 20,68 bar)
Transmitter output
A(1)4–20 mA with digital signal based on HART® Protocol
FFOUNDATION™ Fieldbus Protocol
W(2)PROFIBUS® PA Protocol
X(3)Wireless (requires wireless options and engineered polymer housing)
M(4)Low-power 1–5 Vdc with digital signal based on HART Protocol 
Process connection size, material, extension length (high side)
CodeProcess connection sizeMaterialExtension length
G0(5)2-in./DN 50/A316L SSTFlush mount only

H0 (5)2-in./DN 50Alloy C-276Flush mount only
J02-in./DN 50TantalumFlush mount only
A0(5)3-in./DN 80316L SSTFlush mount
A2(5)3-in./DN 80316L SST2-in./50 mm
A4(5)3-in./DN 80316L SST4-in./100 mm
A6(5)3-in./DN 80316L SST6-in./150 mm
B0(5)4-in./DN 100316L SSTFlush mount
B2(5)4-in./DN 100316L SST2-in./50 mm
B4(5)4-in./DN 100316L SST4-in./100 mm
B6(5)4-in./DN 100316L SST6-in./150 mm
C0(5)3-in./DN 80Alloy C-276Flush mount
C2(5)3-in./DN 80Alloy C-2762-in./50 mm
C4(5)3-in./DN 80Alloy C-2764-in./100 mm
C6(5)3-in./DN 80Alloy C-2766-in./150 mm
D0(5)4-in./DN 100Alloy C-276Flush mount
D2(5)4-in./DN 100Alloy C-2762-in./50 mm
D4(5)4-in./DN 100Alloy C-2764-in./100 mm
D6(5)4-in./DN 100Alloy C-2766-in./150 mm
E03-in./DN 80TantalumFlush mount only
F04-in./DN 100TantalumFlush mount only
Mounting flange size, rating, material (high side)
 SizeRatingMaterial
M2-in.ANSI/ASME B16.5 Class 150CS
A3-in.ANSI/ASME B16.5 Class 150CS
B4-in.ANSI/ASME B16.5 Class 150CS
N2-in.ANSI/ASME B16.5 Class 300CS
C3-in.ANSI/ASME B16.5 Class 300CS
D4-in.ANSI/ASME B16.5 Class 300CS
P2-in.ANSI/ASME B16.5 Class 600CS
E3-in.ANSI/ASME B16.5 Class 600CS
X(5)2-in.ANSI/ASME B16.5 Class 150316 SST
F(5)3-in.ANSI/ASME B16.5 Class 150316 SST
G(5)4-in.ANSI/ASME B16.5 Class 150316 SST
Y(5)2-in.ANSI/ASME B16.5 Class 300316 SST
H(5)3-in.ANSI/ASME B16.5 Class 300316 SST
J(5)4-in.ANSI/ASME B16.5 Class 300316 SST
Z(5)2-in.ANSI/ASME B16.5 Class 600316 SST
L(5)3-in.ANSI/ASME B16.5 Class 600316 SST
QDN 50PN 10-40 per EN 1092-1CS
RDN 80PN 40 per EN 1092-1CS
SDN 100PN 40 per EN 1092-1CS
VDN 100PN 10/16 per EN 1092-1CS
K(5)DN 50PN 10-40 per EN 1092-1316 SST
T(5)DN 80PN 40 per EN 1092-1316 SST
U(5)DN 100PN 40 per EN 1092-1316 SST
W(5)DN 100PN 10/16 per EN 1092-1316 SST
7(5)4 in.ANSI/ASME B16.5 Class 600316 SST
1N/A10K per JIS B2238CS 
2N/A20K per JIS B2238CS 
3N/A40K per JIS B2238CS 
4(5)N/A10K per JIS B2238316 SST 
5(5)N/A20K per JIS B2238316 SST 
6(5)N/A40K per JIS B2238316 SST 
Seal fill fluid (high side)Specific gravityTemperature limits (ambient temperature of 70° F [21° C])
DSilicone 2000.93–49 to 401 °F (–45 to 205 °C)
FSilicone 200 for vacuum applications0.93For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
LDow Corning® 704 diffusion pump fluid1.0732 to 401 °F (0 to 205 °C)
CD.C. Silicone 704 for vacuum applications1.07For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
ASYLTHERM XLT0.85–102 to 293 °F (–75 to 145 °C)
HInert (halocarbon)1.85–49 to 320 °F (–45 to 160 °C)
GGlycerin and water1.135 to 203 °F (–15 to 95 °C)
NNeobee® M-200.925 to 401 °F (–15 to 205 °C)
PPropylene glycol and water1.025 to 203 F (–15 to 95 °C)
Low pressure side
 ConfigurationFlange adapterDiaphragm materialSensor fill fluid
11(5)GageSST316L SSTSilicone
21DifferentialSST316L SSTSilicone
22(5)DifferentialSSTAlloy C-276Silicone
2A(6)DifferentialSST316L SSTInert (halocarbon)
2B(5) (6)DifferentialSSTAlloy C-276Inert (halocarbon)
31(5)Tuned-system assembly with remote sealNone316L SSTSilicone (requires option code S1)
O-ring
AGlass-filled PTFE
Housing materialConduit entry size 
AAluminum½–14 NPT
BAluminumM20 x 1.5
EAluminum, ultra low copper½–14 NPT 
FAluminum, ultra low copperM20 x 1.5 
JSST½–14 NPT
KSSTM20 x 1.5
P(7)Engineered polymerNo conduit entries
D(8)Aluminum 
M(8)SST 
Wireless options (requires wireless output code X and Engineered Polymer Housing code P)
Wireless transmit rate, operating frequency, and protocol
WA3User configurable transmit rate, 2.4 GHz WirelessHART
Antenna and SmartPower
WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
Options (include with selected model number)
Extended product warranty
WR33-year limited warranty
WR55-year limited warranty
Plantweb control functionality(9)
A01FOUNDATION Fieldbus Control Function Block Suite
Plantweb diagnostic functionality
DA0(20)Loop Integrity HART Diagnostic
D01(9)FOUNDATION Fieldbus diagnostics suite
Seal assemblies(10)
S1Assembled to One Rosemount 1199 Seal
Product certifications 
E8ATEX Flameproof and Dust Certification
I1(11)ATEX Intrinsic Safety and Dust
IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
N1ATEX Type n Certification and Dust
K8ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1)
E4(12)TIIS Flameproof
E5FM Explosion-proof, Dust Ignition-proof
I5(13)FM Intrinsically Safe, Nonincendive
IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K5FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
I6(7)CSA Intrinsic Safety
K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
E7IECEx Flameproof, Dust Ignition-proof
I7IECEx Intrinsic Safety
N7IECEx Type n Certification
K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
E2INMETRO Flameproof
I2INMETRO Intrinsic Safety
IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K2INMETRO Flameproof, Intrinsic Safety
E3China Flameproof
I3China Intrinsic Safety
N3China Type n
EMTechnical Regulations Customs Union (EAC) Flameproof
IMTechnical Regulations Customs Union (EAC) Intrinsic Safety
KMTechnical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety
KBFM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
KDFM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
EP(14)Republic of Korea Flameproof
IP(15)Republic of Korea Intrinsic Safety
KP(16)Republic of Korea Flameproof, Intrinsic Safety
Shipboard approvals(7)
SBSAmerican Bureau of Shipping
SBV(17)Bureau Veritas (BV) 
SDNDet Norske Veritas 
SLL(17)Lloyds Register (LR) 
Bolting material
L4Austenitic 316 SST bolts
L5ASTM A 193, grade B7M bolts
L6Alloy K-500 Bolts
L8ASTM A 193 Class 2, grade B8M bolts
Display and interface options
M4(18)LCD display with LOI
M5LCD display
Calibration certification
Q4Calibration Certificate
QPCalibration Certificate and tamper evident seal
QG(19)Calibration Certificate and GOST Verification Certificate
Material traceability certification
Q8Material Traceability Certification per EN 10204 3.1
Quality certification for safety(20)
QSPrior-use certificate of FMEDA data
QTSafety certified to IEC 61508 with certificate of FMEDA
Toolkit total system performance reports
QZSeal system performance calculation report
Conduit electrical connector(6)
GEM12, 4-pin, male connector (eurofast)
GMA size Mini, 4-pin, male connector (minifast)
Configuration buttons
D4(20)Analog zero and span
DZ(21)Digital zero trim
Transient protection(6)(22)
T1Transient protection
Software configuration(21)
C1

Custom Software Configuration

(For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)

Low power output
C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only) 
Alarm levels(20)
C4(23)NAMUR alarm and saturation levels, high alarm
CN(23)NAMUR alarm and saturation levels, low alarm
CRCustom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
CSCustom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
CTRosemount Standard low alarm
Conduit plug
DO316 SST Conduit Plug
Ground screw(6)(24)
V5External ground screw assembly
Lower housing flushing connection options
 Ring materialNumberSize (NPT)
F1316 SST1¼–18 NPT
F2316 SST2¼–18 NPT
F3Alloy C-2761¼–18 NPT
F4Alloy C-2762¼–18 NPT
F7316 SST1½–14 NPT
F8316 SST2½–14 NPT
F9Alloy C-2761½–14 NPT
F0Alloy C-2762½–14 NPT
Lower housing intermediate gasket material
S0No gasket for lower housing
SY(25)Thermo-Tork® TN-9000
NACE certificate(26)
Q15Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
Q25Certificate of compliance to NACE MR0103 for wetted materials
HART Revision configuration(1) (requires HART protocol output code A)
HR5Configured for HART Revision 5
HR7Configured for HART Revision 7
Typical model number: 3051L 2 A A0 D 21 A A F1

 

 

Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

If needed, please contact us for specific prices.

 

OUR MAIN BRAND:

Hot Products

Multi Mode Modicon Quantum PLC Unity Processor 140CPU67160 266 MHz Frequency Quick details: ...
140CRA21110 Modicon Quantum PLC Automation TSX Quantum Platform Processor Specifications Main Range ...
Schneider Electric 140XBP00400 Quantum backplane 4 slots New Original 1 Primary ring, copper/fiber ...
Modicon Quantum PLC 140CPU65160 1 USB Clock frequency 166 MHz Specifications OF Modicon Quantum PLC ...
Modicon Quantum PLC 140DRA84000 32 /24 V DC 4 Group of channels Specifications OF Modicon Quantum ...
Modicon Quantum PLC 140DRA84000 2 W Analogue input number 8 Specifications OF Modicon Quantum PLC ...